Base de dados : LILACS
Pesquisa : 517297 [Identificador único]
Referências encontradas : 1 [refinar]
Mostrando: 1 .. 1   no formato [Detalhado]

página 1 de 1

  1 / 1 LILACS  
             
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
(texto :
PT)
Texto completo SciELO Brasil
(texto :
EN)
Texto completo SciELO Brasil
(texto :
ES)
Mesquita, Evandro Tinoco
experimentalDocumentos relacionados
Id: 517297
Autor: Barbirato, Gustavo Borges; Azevedo, Jader Cunha de; Felix, Renata Christian Martins; Correa, Patricia Lavatori; Volschan, André; Viegas, Monica; Pimenta, Lucia; Dohmann, Hans Fernando Rocha; Mesquita, Evandro Tinoco; Mesquita, Claudio Tinoco.
Título: Uso da cintilografia miocárdica em repouso durante dor torácica para descartar infarto agudo do miocárdio / Utilización de la centellografía miocárdica en reposo durante dolor torácico para descartar infarto agudo de miocardio / Use of resting myocardial scintigraphy during chest pain to exclude diagnosis of acute myocardial infarction
Fonte: Arq. bras. cardiol;92(4):269-274, abr. 2009. ilus, graf, tab.
Idioma: pt; en; es.
Resumo: FUNDAMENTO: A imagem de perfusão miocárdica adquirida durante episódio de dor torácica tem sido utilizada nos pacientes na sala de emergência. OBJETIVO: Avaliar as características operacionais da cintilografia com 99mTc-Tetrofosmin durante episódio de dor torácica para descartar o diagnóstico de infarto agudo do miocárdio. MÉTODOS: 108 pacientes admitidos com dor torácica ou até quatro horas do término dos sintomas e eletrocardiograma não diagnostico realizaram cintilografia em repouso e dosagens de troponina I. Pacientes com passado de infarto do miocárdio (IM) não foram excluídos (24 pacientes). Troponina I foi dosada na admissão e seis horas após. Médicos nucleares realizaram análise cega das imagens. Infarto do miocárdio foi confirmado com elevação da troponina I maior que três vezes o controle. RESULTADOS: A imagem perfusional de repouso foi anormal em todos os seis pacientes com IM. Apenas um paciente apresentou imagem normal e elevação da troponina. Outros 55 pacientes obtiveram imagem positiva sem IM e 46 pacientes com imagens e troponinas normais. A prevalência da doença foi 6,5 por cento. A sensibilidade da imagem de repouso durante dor torácica para a evidência de IM foi 85,7 por cento e especificidade de 45,5 por cento. O valor preditivo negativo foi 97,7 por cento. CONCLUSÃO: Pacientes submetidos ao protocolo de dor torácica com cintilografia de perfusão miocárdica demonstraram um excelente valor preditivo negativo para afastar o diagnóstico de infarto do miocárdio. Estes resultados sugerem que a imagem de perfusão em repouso é uma ferramenta importante na unidade de dor torácica.(AU)

BACKGROUND: Images of myocardial perfusion taken during an episode of chest pain have been used for patients in the emergency department. OBJECTIVE: To evaluate the operating characteristics of 99mTc-Tetrofosmin scintigraphy during an episode of chest pain to exclude the diagnosis of acute myocardial infarction. METHODS: One hundred and eight patients admitted with chest pain, or up to four hours after the end of symptoms and nondiagnostic electrocardiogram, underwent resting scintigraphy and measurement of troponin I concentrations. Patients with a history of myocardial infarction (MI) were not excluded (24 patients). Troponin I concentrations were determined at admission and 6 hours later. Nuclear physicians performed a blind analysis of the images, and myocardial infarction was confirmed whenever troponin I level increase was three times that of the control. RESULTS: Resting perfusion image was abnormal in all 6 patients with MI. Only 1 patient had a normal image and increased troponin levels. Fifty-five patients had positive images without MI, and 46 patients had normal images and troponin levels. The prevalence of the disease was 6.5 percent. The sensitivity and specificity of the resting images during an episode of chest pain to diagnose MI was 85.7 percent and 45.5 percent, respectively. The negative predictive value was 97.7 percent. CONCLUSION: Patients undergoing chest pain protocol with SPECT showed an excellent negative predictive value to exclude diagnosis of myocardial infarction. These results suggest that resting perfusion image is an important tool at the chest pain unit.(AU)

FUNDAMENTO: La utilización en los pacientes de la imagen de perfusión miocárdica, adquirida durante episodio de dolor torácico, es frecuente en la sala de emergencia. OBJETIVO: Evaluar las características operacionales de la centellografía con 99mTc-Tetrofosmin, durante episodio de dolor torácico, para descartar el diagnóstico de infarto agudo de miocardio. MÉTODOS: Un total de 108 pacientes ingresados con dolor torácico, o hasta tras 4 horas del término de los síntomas, con electrocardiograma no diagnostico, realizaron centellografía en reposo y dosificaciones de troponina I. No se excluyeron a los pacientes con pasado de infarto de miocardio (IM) (24 pacientes). Se dosificó troponina I al ingreso y tras 6 horas del ingreso. Médicos nucleares realizaron análisis ciego de las imágenes. Se confirmó infarto de miocardio, con elevación de la troponina I mayor que tres veces el control. RESULTADOS: La imagen de perfusión en reposo se mostró anormal en todos los seis pacientes con IM. Sólo un paciente presentó imagen normal y elevación de la troponina. Otros 55 pacientes obtuvieron imagen positiva sin IM y 46 pacientes presentaron imágenes y troponinas normales. La prevalencia de la enfermedad fue de un 6,5 por ciento. Fue de un 85,7 por ciento la sensibilidad de la imagen de reposo durante dolor torácico para la evidencia de IM, y la especificidad de un 45,5 por ciento. El valor predictivo negativo fue de un 97,7 por ciento. CONCLUSIÓN: Pacientes sometidos al protocolo de dolor torácico con centellografía de perfusión miocárdica demostraron un excelente valor predictivo negativo para la exclusión del diagnóstico de infarto de miocardio. Estos resultados sugieren que la imagen de perfusión en reposo es una herramienta importante en la unidad de dolor torácico.(AU)
Descritores: Dor no Peito/cintilografia
Infarto do Miocárdio/cintilografia
Compostos Organofosforados/uso diagnóstico
Compostos de Organotecnécio/uso diagnóstico
Compostos Radiofarmacêuticos/uso diagnóstico
-Marcadores Biológicos/sangue
Brasil
Dor no Peito/sangue
Diagnóstico Diferencial
Métodos Epidemiológicos
Infarto do Miocárdio/sangue
Descanso
Troponina I/sangue
Limites: Feminino
Humanos
Masculino
Meia-Idade
Tipo de Publ: Estudos de Avaliação
Responsável: BR1.1 - BIREME



página 1 de 1
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde