Database : IBECS
Search on : D02.241.223.100.050.500.968 [DeCS Category]
References found : 12 [refine]
Displaying: 1 .. 10   in format [Large]

page 1 of 2 go to page        

  1 / 12 IBECS  
              next record last record
select
to print
Photocopy
Full text
Id: 151547
Author: Piris-García, X; Tazón-Varela, M; Pérez-Mier, LA; Gortazar-Salazar, E; Vásquez-Sánchez, A.
Title: Traumatismo ocular con cuerpo extraño intraocular / Eye injury with an intraocular foreign body
Source: SEMERGEN, Soc. Esp. Med. Rural Gen. (Ed. Impr.);42(3):197-199, abr. 2016. ilus.
Language: es.
Abstract: No disponible

No disponible
Responsable: ES1.1
BNCS


  2 / 12 IBECS  
              first record previous record next record last record
select
to print
Photocopy
Id: 137567
Author: Asensio, I; Palanca-Sanfrancisco, JM; Granell-Gil, M; Alonso, L; Rahhal, MS; Martinez-Soriano, F; Sanchis-Gimeno, JA.
Title: The effect of a combination of 0.1% tetracaine HCl and 0.4% oxybuprocaine HCl on human central corneal thickness measurements
Source: Eur. j. anat;8(1):7-10, mayo 2004. graf, ilus.
Language: en.
Abstract: A combination of 0.1% tetracaine HCl and 0.4% oxybuprocaine HCl is used when carrying out morphometrical corneal studies in vivo by means of ultrasound pachymetry. The aim of this was to determine the effect of a combination of 0.1% tetracaine HCl and 0.4% oxybuprocaine HCl anesthetic eye drops on central corneal thickness values. We carried out a prospective study involving 30 eyes of 30 healthy subjects. The mean age of the subjects was 26.13±2.62 years (age ranged from 20 to 30 years old). Central pachymetry was carried out prior to and three minutes after the instillation of two saline solution eye drops, and three minutes after the administration of a combination of 0.1% tetracaine HCl and 0.4% oxybuprocaine HCl anesthetic eye drops. The mean of three consecutive measurements of the central corneal thickness obtained with the Orbscan Topography System II (Orbscan, Inc., Salt Lake City, UT. USA) was used as the corneal thickness value. No significant differences were found (p=0.714) in the mean central corneal thickness values before and three minutes after saline solution eye drops had been instilled. Nevertheless, after anesthesia there was a significant increase in mean central corneal thickness (p<0.001). Increases ranged from 22 to 131 micrometers, with a mean of approximately 47 micrometers. Following the instillation of a combination of 0.1% tetracaine HCl and 0.4% oxybuprocaine HCl eye drops corneal thickness increase. Researchers must be aware of this effect of topical anesthetic eye drops on corneal morphometry in order to analyze corneal thickness results correctly (AU)

No disponible
Responsable: ES1.1
BNCS


  3 / 12 IBECS  
              first record previous record next record last record
select
to print
Photocopy
Full text SciELO Spain
Id: 76286
Author: Valls Durán, T; Díaz Sanisidro, E; Nadal González, L.
Title: Uso del gel LAT para suturar heridas en niños / No disponible
Source: Pediatr. aten. prim;11(44):575-585, oct.-dic. 2009. tab.
Language: es.
Abstract: Introducción: las laceraciones traumáticas que precisan puntos de sutura son uno de losmotivos de consulta urgente más frecuentes en pediatría. Conseguir la mejor anestesia de lazona causando el mínimo dolor posible es el paso previo y fundamental para una correcta reparaciónde la lesión en óptimas condiciones. El objetivo de este trabajo es comprobar la eficaciadel gel anestésico LAT (lidocaína, 1,5%; adrenalina, 0,1%; y tetracaína, 1%) para suturarlas heridas no complicadas en pacientes pediátricos.Material y métodos: fueron incluidos los pacientes pediátricos que acudieron a nuestrocentro de salud con heridas para suturar desde julio de 2007 hasta diciembre del año siguiente.El dolor sentido se midió mediante la escala visual analógica (EVA) en los niños que podíanexpresarse verbalmente, y a través de la Face Pain Scale (FPS) en los más pequeños.Resultados: se incluyó un total de 106 pacientes. La media de edad fue de 5,94 años, y lamedida del dolor fue de 1,34 en el grupo valorado mediante EVA y de 1,67 en el de la FPS.La eficacia fue significativamente mayor cuando las heridas se situaban en la cara o el cuerocabelludo con respecto a las extremidades. No hubo complicaciones importantes (el seguimientose llevó a cabo mediante una llamada telefónica) y los pacientes y sus familias quedaronsatisfechos.Conclusiones: la aplicación de gel LAT resulta útil para suturar heridas no complicadasen niños sin ocasionar dolor, especialmente cuando éstas se localizan en la cara y el cuero cabelludo(AU)

Introduction: traumatic lacerations requiring suturing stitches are one of the most frequentreasons of emergencies in paediatrics. Achieving the best anesthesia of the area in orderto cause the minimum pain possible is the previous and basic step to a successful repairof the injury under ideal conditions. The aim of this work is to check the LAT anesthetic gelefficacy (lidocaine, 1.5%; adrenalin, 0.1%; tetracaine, 1%) in order to suture no complicatedwounds in paediatric patients. Material and methods: paediatric patients coming to our health centre to get theirwounds sutured from July 2007 to December 2008 were included. The evaluation of thepain felt was measured by using the Visual Analogue Scale (VAS) in those children whocould express themselves verbally and by the Face Pain Scale (FPS) in the younger ones.Results: a total of 106 patients were included. Mean age was 5.94 years, and the measurementof pain 1.34 in the group evaluated by VAS, and 1.67 in the one evaluated by FPS. Effectivenesswas significantly higher with wounds located on face or scalp compared to thosein the extremities. There were no major complications (monitored by phone call) and patientsand their families seemed to be pleased.Conclusions: LAT gel application is useful for suturing no complicated wounds in childrenwithout causing pain, especially with wounds located on face and scalp(AU)
Responsable: ES1.1
BNCS


  4 / 12 IBECS  
              first record previous record next record last record
select
to print
Photocopy
Full text SciELO Spain
Id: 64537
Author: Yebra-Pimentel, E; González-Méijome, JM; García-Resúa, C; Giráldez-Fernández, MJ.
Title: Relación entre los componentes ópticos oculares e implicaciones en el proceso de emetropización / The realtionships between ocular optical components and implication sin the process of emmetropization
Source: Arch. Soc. Esp. Oftalmol;83(5):307-316, mayo 2008. ilus, tab.
Language: Es.
Abstract: Objetivo: Determinar la relación entre los diferentes componentes ópticos oculares y la emetropizaciónen función de la longitud axial (LA).Métodos: Participaron 109 jóvenes universitariosdivididos en cinco grupos según el error refractivo:emétropes, hipermétropes, miopes bajos, miopesmoderados y miopes altos. La medida de los parámetrosintraoculares y el análisis de la topografíacorneal se realizó mediante ultrasonografía y videoqueratoscopiarespectivamente.Resultados: Se encontró una correlación estadísticamentesignificativa entre la profundidad de lacámara anterior (PCA) y la LA en ojos con LAmenor de 24 mm (r = 0,441; p < 0,001). Sin embargoen ojos con LA mayor no se encontró tal relación(r = 0,098; p = 0,527). El espesor del cristalino(EC) mostró una correlación inversa con la LApara los ojos con LA < 24 mm (r = 0,391; p <0,001), siendo nula en el caso de ojos con LA >= 24 mm. La curvatura corneal (RC) sólo mostró unadébil correlación con la profundidad de la cámaravítrea (PCV) en ojos con LA < 24 mm (r = 0,363; p< 0,003).Conclusión: Los parámetros ópticos del ojo humanose relacionan de distinta forma según el tamañodel ojo, encontrándose en los ojos más miopes unaausencia de coordinación entre los componentesópticos oculares, que según los resultados de esteestudio, es a partir de 2,00 D (AU)

Purpose: To report the relationship between different optical ocular components and the influence ofaxial length on emmetropization.Methods: 109 young university students, dividedinto five groups, were enrolled in this study: emmetropes,hyperopes, low myopes, moderate myopesand high myopes. Intraocular parameters and topographiccorneal analyses were performed by ultrasonographyand videokeratoscopy respectively.Results: Anterior chamber depth and axial lengthwere found to correlate significantly in eyes withaxial lengths less than 24 mm (r = 0.441; p < 0.001)However this correlation was not found in eyes withlonger axial lengths (r = 0.098; p = 0.527). Lensthickness showed an inverse correlation with axiallength for shorter eyes (r = 0.391; p < 0.001), whereasany correlation in longer eyes was associatedwith moderate to high levels of myopia. Anteriorcorneal curvature only correlated, although weakly, with vitreous chamber depth for shorter eyes (r =0.363; p < 0.003).Conclusion: Differences in optical parameters ofthe human eye displayed different associations inlonger eyes. A lack of correlation was seen betweenocular components in eyes with higher myopia, corresponding to myopia in excess of 2.00 D (AU)
Responsable: ES15.1 - Biblioteca Nacional de Ciencias de la Salud
ES15.1 - BNCS


  5 / 12 IBECS  
              first record previous record next record last record
select
to print
Photocopy
Full text SciELO Spain
Id: 59614
Author: Miranda-Rollón, M. D; Pérez-González, L. E; Sentieri-Omarrementería, A; Martínez-Rodríguez, R; Parente-Hernández, B; Junceda-Moreno, J.
Title: Cirugía del pterigión: estudio comparativo entre autoinjerto conjuntival con sutura y con adhesivo tisular / Pterygium sugery: comparative study of conjuctival autograft with suture versus fibrin adhesive
Source: Arch. Soc. Esp. Oftalmol;84(4):179-184, abr. 2009. ilus, tab.
Language: es.
Abstract: Objetivo: Comparar la tasa de recurrencias, complicacionesy hallazgos biomicroscópicos despuésde cirugía de pterigión con autoinjerto conjuntivalusando adhesivo tisular (Tissucol Duo®, BaxterAG, Viena, Austria) o sutura (seda 7-0).Material y métodos: Se han incluido en el estudiopacientes con pterigión nasal en dos grupos de cirugíade autoinjerto conjuntival: en 9 de ellos el injertose sutura a conjuntiva y en 8 de ellos se fija conadhesivo tisular.Resultados: Se intervinieron 17 ojos de 17 pacientes,41,2% mujeres y 58,8% hombres con edadmedia de 59,8 años. 5 ojos presentaban recurrenciade resección simple y 12 de ellos presentaban pterigiónprimario. El tamaño de la invasión cornealosciló entre 2 y 4 mm. 33,3% de los pacientes delgrupo de sutura presentaron molestias después de lacirugía frente a ninguno en el grupo de adhesivo.44,4% de los pacientes presentaron inflamación trasla cirugía frente a ninguno en el grupo de sutura. Enuno de los pacientes del grupo del adhesivo se produjo una pérdida del injerto causando una posteriorrecidiva del pterigión.Conclusiones: El uso de adhesivo tisular reduce lossíntomas postquirúrgicos así como la inflamación yel disconfort. La tasa de recurrencias parece sersimilar con los dos procedimientos(AU)

Purpose: To compare recurrence rate, complications,and biomicroscopical findings after conjunctivalautograft pterygium surgery with the use of afibrin glue (Tissucol Duo®, Baxter AG, Vienna,Austria) or suture (7-0 silk).Methods: Patients with nasal pterygium wereincluded in two groups of conjunctival autograftsurgery. In 9 of them the graft was sutured to thesurrounding conjunctiva and in 8 of them the graftwas fixed to the conjunctiva using fibrin glue.Results: 17 patients (17 eyes) 41.2% women and58.8% men were surgically treated. Mean patient agewas 59.8 years. Five of the patients presented recurrencefor simple excision and 12 presented primary pterygium.The extent of corneal invasion was 2 to 4 mm. Inthe suture group, 33.3% of the patients experiencedpain after surgery compared to none in the fibrin gluegroup. In the suture group, 44.4% of the patients presentedinflammation after surgery compared to none inthe glue group. One patient from the glue group lost thegraft and presented a recurrence one month later. Conclusions: The use of fibrin glue in pterygiumsurgery reduces patient symptoms, inflammationand discomfort. The rate of recurrence seems to besimilar in both procedures(AU)
Responsable: ES1.1
BNCS


  6 / 12 IBECS  
              first record previous record next record last record
select
to print
Photocopy
Full text SciELO Spain
Id: 59576
Author: Abreu, J. A; Aguilar, J. J; Capote, E; Abreu, R.
Title: Anestesia peritópica en cirugía decatarata / Peritopic anesthesia in cataract surgery
Source: Arch. Soc. Esp. Oftalmol;84(2):63-64, feb. 2009.
Language: es.
Responsable: ES1.1
BNCS


  7 / 12 IBECS  
              first record previous record next record last record
select
to print
Photocopy
Full text SciELO Spain
Id: 59566
Author: Díaz-Rey, J. A; Giráldez, M. J; García-Resúa, C; Yebra-Pimentel, E.
Title: Efecto de la instilación del Colicursi® anestésico doble (tetracaína 0.1% y oxibuprocaína 0.4%) sobre el espesor corneal central y paracentral / Effect of double anaesthetic colicursi® (tetracaine 0.1% and oxibuprocaine 0.4%) on central and paracentral corneal thickness
Source: Arch. Soc. Esp. Oftalmol;84(1):23-30, ene. 2009. tab, graf.
Language: es.
Abstract: Objetivo: El objetivo del presente trabajo es estudiarel efecto sobre el espesor corneal central (ECC)y paracentral a 2,5 mm del centro en los hemimeridianosnasal, temporal, superior e inferior, de laanestesia tópica en la que se combinan el clorhidratode tetracaina 0,1% y el clorhidrato de oxibuprocaina0,4%.Material y método: Se determinó el espesor cornealcentral y paracentral a 2,5 mm del centro dela córnea en los ojos derechos de 12 varonesjóvenes mediante Orbscan. Las medidas se realizaroncada dos minutos durante un periodo de 16minutos previo y posterior a la instilación delanestésico.Resultados: El análisis estadístico muestra que noexiste variación en el espesor corneal central y paracentralantes y después de la instilacion del anestésicoColircusi® anestésico doble con clorhidratotetracaina 0,1% y clorhidrato de oxibuprocaina0,4% (ANOVA para medidas repetidas, p>0,05).Aunque no fueron estadísticamente significativas lamayor variación de espesor se observa para el ECCa los 6 minutos y para el paracentral a los 8 minutosen el hemimeridiano nasal.Conclusiones: Una gota de Colircusi® anestésicodoble con clorhidrato tetracaina 0,1% y clorhidratode oxibuprocaina 0,4% no produce una variaciónsignificativa del ECC ni paracentral a 2 mm del centroen los hemimeridianos nasal, temporal, superior e inferior(AU)

Objective: To study the effect of 1 drop of combinedtopical anaesthesia (tetracaine 0.1% and oxybuprocaine0.4%) on central corneal thickness (CCT)values and at 2.5 mm from the corneal centre innasal, temporal, superior and inferior hemi meridians,monitored by Orbscan over a period of 16minutes.Materials and methods: The corneal thickness of12 right eyes of 12 young healthy men was determinedusing the Orbscan Topography System. Valueswere determined at the centre and paracentralregions 2.5 mm from the centre every 2 minutes for16 minutes before and after the administration of 1drop of double anaesthetic Colircusi® which containstetracaine 0.1% and oxybuprocaine 0.4%.Results: There was no obvious trend of central andparacentral corneal thickness value change beforeand after administration of Colircusi® (pairedANOVA, p>0.05). Although corneal thicknessvariation was not statistically significant, higherdifferences were observed at the 6 minute timepoint for CCT and at 8 minutes for nasal paracentralcorneal thickness.Conclusions: One drop of double anaestheticColircusi® with tetracaine 0.1% and oxibuprocaine0.4% does not produce any significant change incentral corneal thickness or in paracentral regions2.5 mm from the centre (nasal, temporal, superiorand inferior hemi meridians)(AU)
Responsable: ES1.1
BNCS


  8 / 12 IBECS  
              first record previous record next record last record
select
to print
Photocopy
Id: 049217
Author: Alañón Fernández, MA; Alañón Fernández, FJ; Martínez Fernández, A; Cárdenas Lara, M.
Title: Resultados de la aplicación de mitomicina en la dacriocistorrinostomía endonasal y endocanalicular con láser diodo / Results the application of mitomicyn during endonasal and endocanalicular dacryocystorhinostomy by diode laser
Source: Acta otorrinolaringol. esp;57(8):355-358, oct. 2006. ilus.
Language: Es.
Abstract: Objetivo: Valorar el beneficio, efectos secundarios y seguridad de la aplicación de mitomicina C (MMC) de forma intraoperatoria, durante la realización de una dacriocistorrinostomía endonasal y endocanalicular con láser diodo (TLA-ELA DCR). Métodos: Se realizó un estudio prospectivo randomizado, intervencional y doble ciego. Se estudiaron 200 pacientes a 150 pacientes se les aplicó MMC intraoperatoria (0,4 mg/0,2 ml) durante un tiempo de 5 minutos, mediante un apósito de acetato de polivinilo que se coloca sobre la osteotomía. En el resto de pacientes fueron revisados a las 24 horas, 10 días, 1, 3 y 6 meses postcirugía. Se estudió el aspecto endoscópico y las posibles complicaciones. Los resultados se comparan mediante el test de Chi-cuadrado con la corrección de Yates. Se estudió la presencia o ausencia de efectos secundarios por la aplicación de MMC. Resultados: El seguimiento medio fue 15,25 meses (rango= 6-21 meses). El porcentaje de alteraciones por cicatrización excesiva fue del 21,77% y del 8,03%, en los pacientes sin y con MMC respectivamente. La diferencia fue estadísticamente significativa (p=0,02). No hubo efectos secundarios por la aplicación de MMC. Conclusiones: La aplicación de MMC intraoperatoria tópica durante TLA-ELA DCR disminuye los hallazgos patológicos por cicatrización del área periférica al nuevo drenaje sin producir efectos secundarios

Aim of the study: To study the effects, secondary effects and security of the intrasurgical application of mitomicyn C during endonasal and endocanalicular dacryocystorhinostomy with diode laser (TLA-ELA DCR). Methods: We carried out a randomized, prospective, interventional and double blind study in 200 patients: intrasurgical mitomicyn C was applied in 150 of then (0.4 mgr/0.2 ml) for 5 minutes by means of a polivinil acetate dressing over the osteotomy. In other 50 patients MMC was not used we followed up at 24 hours, 10 days and 1, 3 and 6 months after surgery. Endoscopic aspects and possible complications were valued. The results were compared using the Chi-squared test with the Yates correction. We looked for the presence or abscense of secondary effects in the application of mitomicyn C. Results: The average follow up was 15.25 months (range 6 to 21 months). The percentages of alterations for excesive scarring were 21.77% in patients without and MAC 8.03% in the ones MMC. The difference was statisticaly significant (p= 0.02). We did not find secondary effects due to application of mitomcyn. Conclusions: Intrasurgical application of topical MMC during TLA-ENL DCR reduces the number of pathological findings due to scarring of the surrouding area of the new drainage without secondary effects
Responsable: ES1.1
ES1.1 - BNCS


  9 / 12 IBECS  
              first record previous record next record last record
select
to print
Photocopy
Id: 041606
Author: Asensio-Romero, I; Palanca-Sanfrancisco, JM; Granell Gil, M; Alonso, L; Rahhal, MS; Martínez Soriano, F; Sanchis-Gimeno, JA.
Title: Quantitative central corneal anatomy and anaesthetic eye drops effects: Comparison between 0.4% oxybuprocaine and a combination of 0.1% tetracaine and 0.4% oxybuprocaine
Source: Eur. j. anat;9(2):89-93, sept. 2005. tab.
Language: En.
Abstract: We aimed to analyse the changes in central cornealthickness values following the instillation of0.4% oxybuprocaine eye drops and following acombination of 0.1% tetracaine and 0.4% oxybuprocaineeye drops.Orbscan pachymetry (Orbscan II CornealTopography System; Orbscan, Inc., Salt LakeCity, UT, USA) was carried out before andthree minutes after the instillation of 0.4% oxybuprocaineeye drops, and before and threeminutes after the instillation of a combinationof 0.1% tetracaine and 0.4% oxybuprocaine eyedrops in 35 healthy subjects (n=35; aged 20-30years). After the instillation of 0.4% oxybuprocaineeye drops there was a mean increase incentral corneal thickness of 25±11 microns.After the combination of 0.1% tetracaine and0.4% oxybuprocaine eye drops it rose to 48±20microns. The combination of 0.1% tetracaineand 0.4% oxybuprocaine anaesthetic eye dropscauses higher increases in central cornealthickness values than 0.4% oxybuprocaine eyedrops (AU)

No disponible
Responsable: ES1.1
ES1.1 - BNCS


  10 / 12 IBECS  
              first record previous record
select
to print
Photocopy
Id: 037688
Author: Huerta Brogeras, M; Avilés, JA; González-Carrascosa, M; Cueva, P de la; Suárez, R; Lázaro, P.
Title: Dermatitis sistémica de contacto por tetracaínas / Tetracaine-induced systemic contact-type dermatitis
Source: Allergol. immunopatol;33(2):112-114, mar. 2005. ilus.
Language: Es.
Abstract: Varón de 71 años que presenta lesiones eccemato-purpúricas en zona inguinal, de un día de evolución. 48 horas antes se le había practicado una resección transuretral por hipertrofia benigna de próstata. Durante la intervención se le aplicó el anestésico tópico tetracaína, base del denominado ôlubricante urológicoö (LU), exclusivamente en la sonda uretral y glande. El paciente refería que en anteriores ocasiones había tenido fisuras perianales tras la aplicación de cremas antihemorroidales. Se le realizó biopsia y pruebas alérgicas de contacto que incluyeron la batería estándar de alergenos y los propios del LU. A las 24 y a las 48 horas se confirmó resultado positivo a la mezcla de caínas (+ + +) y LU (+ + +). El LU tópico fue testado en 20 pacientes control, resultando negativo en todos ellos. El diagnóstico fue de eccema sistémico de contacto por caínas. El proceso se resolvió en 7-10 días tras aplicación tópica de corticosteroides, y la toma de antihistamínicos orales

We report the case of a 71-year-old-man with dermatitis in the groin area. Forty-eight hours previously, he had undergone transurethral resection for benign prostatic hyperplasia. During the prostatectomy, the probe was lubricated with a urological ointment containing the topical anesthetic, tetracaine. The patient had previously experienced severe pruritus and fissures in the perianal area after using antihemorrhoidal ointments. Biopsy and patch testing with the standard series and lubricant ointment showed positive reactions to this lubricant, called ôurological lubricantö (UL) (+ + +) with caine mix (+ + +). The patient was diagnosed with systemic contact-type dermatitis due to caine mix. The dermatitis improved with topical steroids and oral antihistamine agents
Responsable: ES1.1
ES1.1 - BNCS



page 1 of 2 go to page        
   


Refine the search
  Database : Advanced form   
Search for : Free form    Basic form

    Search in field  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/PAHO/WHO - Latin American and Caribbean Center on Health Sciences Information