Base de dados : LILACS
Pesquisa : C26.392.500 [Categoria DeCS]
Referências encontradas : 127 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 13 ir para página                         

  1 / 127 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-1130510
Autor: Braguetto, Italo; Korn, Owen; Rojas, Jorge; Valladares, Hector; Figueroa, Manuel.
Título: Hiatal hernia repair: prevention of mesh erosion and migration into the esophagogastric junction / Correção de hérnia hiatal: prevenção de erosão e migração de tela na junção esofagogástrica
Fonte: ABCD arq. bras. cir. dig;33(1):e1489, 2020. tab, graf.
Idioma: en.
Resumo: ABSTRACT Background: Erosion and migration into the esophagogastric lumen after laparoscopic hiatal hernia repair with mesh placement has been published. Aim: To present surgical maneuvers that seek to diminish the risk of this complication. Method: We suggest mobilizing the hernia sac from the mediastinum and taking it down to the abdominal position with its blood supply intact in order to rotate it behind and around the abdominal esophagus. The purpose is to cover the on-lay mesh placed in "U" fashion to reinforce the crus suture. Results: We have performed laparoscopic hiatal hernia repair in 173 patients (total group). Early postoperative complications were observed in 35 patients (27.1%) and one patient died (0.7%) due to a massive lung thromboembolism. One hundred twenty-nine patients were followed-up for a mean of 41+28months. Mesh placement was performed in 79 of these patients. The remnant sac was rotated behind the esophagus in order to cover the mesh surface. In this group, late complications were observed in five patients (2.9%). We have not observed mesh erosion or migration to the esophagogastric lumen. Conclusion: The proposed technique should be useful for preventing erosion and migration into the esophagus.

RESUMO Racional: Com a colocação de tela foi têm sido publicadas erosões e migrações para o lúmen esofagogástrico após correção de hérnia hiatal laparoscópica. Objetivo: Apresentar manobras cirúrgicas que buscam diminuir o risco dessa complicação. Método: Sugerimos mobilizar o saco de hérnia do mediastino e levá-lo à posição abdominal com o suprimento sanguíneo intacto, a fim de girá-lo para trás e ao redor do esôfago abdominal. O objetivo é cobrir a malha colocada sobre a forma "U" para reforçar a sutura da crura haital. Resultados: Realizamos reparo laparoscópico de hérnia hiatal em 173 pacientes (grupo total). Complicações pós-operatórias precoces foram observadas em 35 pacientes (27,1%) e um morreu (0,7%) devido a tromboembolismo pulmonar maciço. Cento e vinte e nove pacientes foram acompanhados por média de 41+28 meses. A colocação da tela foi realizada em 79 desses pacientes. O saco remanescente foi girado atrás do esôfago para cobrir a superfície da tela. Nesse grupo, complicações tardias foram observadas em cinco pacientes (2,9%). Não observamos erosão da tela ou migração dela para o lúmen esofagogástrico. Conclusão: A técnica proposta pode ser útil para prevenir a erosão e a migração para o esôfago de telas na correção de hérnias hiatais.
Descritores: Complicações Pós-Operatórias/prevenção & controle
Telas Cirúrgicas/efeitos adversos
Laparoscopia/efeitos adversos
Herniorrafia/efeitos adversos
Hérnia Hiatal/cirurgia
-Recidiva
Reoperação
Refluxo Gastroesofágico/cirurgia
Refluxo Gastroesofágico/etiologia
Seguimentos
Técnicas de Sutura
Migração de Corpo Estranho
Resultado do Tratamento
Laparoscopia/métodos
Herniorrafia/métodos
Limites: Humanos
Masculino
Feminino
Adulto
Pessoa de Meia-Idade
Idoso
Idoso de 80 Anos ou mais
Responsável: BR1.1 - BIREME


  2 / 127 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-892921
Autor: Floyd J, Michael S; Omar, Ahmad M; Khattak, Altaf Q.
Título: Re: unusual intravesical foreign body in a young female migrated from the vagina due to autoerotism
Fonte: Int. braz. j. urol;43(6):1196-1197, Nov.-Dec. 2017.
Idioma: en.
Descritores: Vagina
Corpos Estranhos
-Migração de Corpo Estranho
Limites: Humanos
Feminino
Tipo de Publ: Comentário
Carta
Responsável: BR1.1 - BIREME


  3 / 127 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-892859
Autor: Korkes, Fernando.
Título: Nutcracker syndrome: how are we cracking the nuts and whose nuts are we cracking?
Fonte: Int. braz. j. urol;43(4):788-790, July-Aug. 2017. graf.
Idioma: en.
Descritores: Síndrome do Quebra-Nozes/cirurgia
Síndrome do Quebra-Nozes/diagnóstico por imagem
-Stents/efeitos adversos
Fatores de Risco
Migração de Corpo Estranho/complicações
Diagnóstico Diferencial
Limites: Humanos
Feminino
Adulto
Tipo de Publ: Carta
Responsável: BR1.1 - BIREME


  4 / 127 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-1040053
Autor: Basiri, Abbas; Shakiba, Behnam; Rostaminejad, Niloufar.
Título: Removal of intramural trapped intrauterine device by cystoscopic incision of bladder wall
Fonte: Int. braz. j. urol;45(2):408-409, Mar.-Apr. 2019.
Idioma: en.
Resumo: ABSTRACT A healthy 37 - year - old woman referred to our clinic with one - year history of recurrent urinary tract infection, dysuria and frequency. Her past medical history informed us that an IUD (Copper TCu380A) had been inserted 11 years ago. Eleven months after the IUD insertion she had become pregnant, unexpectedly. At that time, she had undergone gynecological examination and abdominal ultrasound study. However, the IUD had not been found, and the gynecologist had made the diagnosis of spontaneous fall out of the IUD. She had experienced normal pregnancy and caesarian section with no complications. On physical examination, pelvic examination was normal and no other abnormalities were noted. Urinalysis revealed microhematuria and pyuria. Urine culture was positive for Escherichia coli. Ultrasound study revealed a calculus of about 10 mm in the bladder with a hyperdense lesion. A plain abdominal radiograph was requested which showed a metallic foreign body in the pelvis. We failed to remove the IUD by cystoscopic forceps because it had strongly invaded into the uterine and bladder wall. Despite previous papers suggesting open or laparoscopic surgeries in this situation (1, 2), we performed a modified cystoscopic extraction technique. We made a superficial cut in the bladder mucosa and muscle with J - hook monopolar electrocautery and extracted it completely with gentle traction. This technique can decrease the indication of open or laparoscopic surgery for extraction of intravesical IUDs. In the other side of the coin, this technique may increase the risk of uterovesical fistula. Therefore, the depth of incision is important and the surgeon should cut the bladder wall superficially with caution. Although present study is a case report which is normally classified as with low level of evidence, it seems that our modified cystoscopic extraction technique is a safe and useful method for extraction of partially intravesical IUDs.
Descritores: Bexiga Urinária/cirurgia
Remoção de Dispositivo/instrumentação
Cistoscopia/métodos
Dispositivos Intrauterinos/efeitos adversos
-Procedimentos Cirúrgicos em Ginecologia/métodos
Migração de Corpo Estranho/cirurgia
Laparoscopia/métodos
Limites: Humanos
Feminino
Adulto
Tipo de Publ: Relatos de Casos
Responsável: BR1.1 - BIREME


  5 / 127 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-897925
Autor: Wadhawa, Vivek; Doshi, Chirag; Hinduja, Manish; Garg, Pankaj; Patel, Kartik; Mishra, Amit; Shah, Pratik.
Título: Anterior minithoracotomy: a safe approach for surgical asd closure & asd device retrieval
Fonte: Rev. bras. cir. cardiovasc = Braz. j. cardiovasc. surg. (impr.);32(4):270-275, July-Aug. 2017. tab, graf.
Idioma: en.
Resumo: Abstract Objective: Midline sternotomy is the preferred approach for device migration following transcatheter device closure of ostium secundum atrial septal defect. Results of patients operated for device migration were retrospectively reviewed after transcatheter closure of atrial septal defect. Methods: Among the 643 patients who underwent atrial septal defect with closure device, 15 (2.3%) patients were referred for device retrieval and surgical closure of atrial septal defect. Twelve patients underwent device retrieval and surgical closure of atrial septal defect through right antero-lateral minithoracotomy with femoral cannulation. Three patients were operated through midline sternotomy. Results: Twelve patients operated through minithoracotomy did not require conversion to sternotomy. Due to device migration to site of difficult access through thoracotomy, cardiac tamponade and hemodynamic instability, respectively, three patients were operated through midline sternotomy. Mean aortic cross-clamp time and cardiopulmonary bypass time were 28.1±17.7 and 58.3±20.4 minutes, respectively. No patient had surgical complication or mortality. Mean intensive care unit and hospital stay were 1.6±0.5 days and 7.1±2.2 days, respectively. Postoperative echocardiography confirmed absence of any residual defect and ventricular dysfunction. In a mean follow-up period of six months, no mortality was observed. All patients were in New York Heart Association class I without wound or vascular complication. Conclusion: Minithoracotomy with femoral cannulation for cardiopulmonary bypass is a safe-approach for selected group of patients with device migration following transcatheter device closure of atrial septal defect without increasing the risk of cardiac, vascular or neurological complications and with good cosmetic and surgical results.
Descritores: Toracotomia/métodos
Migração de Corpo Estranho/cirurgia
Dispositivo para Oclusão Septal/efeitos adversos
Comunicação Interatrial/cirurgia
-Cateterismo/métodos
Ponte Cardiopulmonar/métodos
Estudos Retrospectivos
Migração de Corpo Estranho/complicações
Resultado do Tratamento
Artéria Femoral
Esternotomia/métodos
Comunicação Interatrial/diagnóstico por imagem
Limites: Humanos
Masculino
Pré-Escolar
Criança
Adolescente
Adulto
Pessoa de Meia-Idade
Idoso
Adulto Jovem
Responsável: BR1.1 - BIREME


  6 / 127 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-897963
Autor: Pillai, Jayandiran; Yazicioglu, Ceyhan; Omar, Mahad; Veller, Martin G.
Título: Stent-graft relining in a patient with acute aortic aneurysm and a completely migrated endograft
Fonte: Rev. bras. cir. cardiovasc = Braz. j. cardiovasc. surg. (impr.);32(6):545-547, Nov.-Dec. 2017. tab, graf.
Idioma: en.
Resumo: Abstract Stent-graft migration and type I endoleaks are associated with a higher rate of reintervention and increased mortality and morbidity. This article describes a patient presented with an infrarenal aortic stent-graft which had migrated into the aortic sac with loss of all aortic neck attachment. The acutely expanding abdominal aortic aneurysm was treated by placing a second modular endograft within and above the migrated stentgraft. The patient returned 36 months later, with features of an acute myocardial infarction, severe bilateral lower limb ischemia, and renal failure. He was too ill for intervention and demised within 48 hours.
Descritores: Stents/efeitos adversos
Migração de Corpo Estranho/diagnóstico por imagem
Aneurisma da Aorta Abdominal/cirurgia
Implante de Prótese Vascular/efeitos adversos
-Aorta Abdominal/cirurgia
Complicações Pós-Operatórias
Tomografia Computadorizada por Raios X
Migração de Corpo Estranho/cirurgia
Evolução Fatal
Procedimentos Endovasculares
Limites: Humanos
Masculino
Idoso
Tipo de Publ: Relatos de Casos
Responsável: BR1.1 - BIREME


  7 / 127 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-897966
Autor: Santos, Eduardo Cavalcanti Lapa; Tchaick, Rodrigo Mezzalira; Ferraz, Diogo Luiz de Magalhães; Oliveira, João Paulo Segundo de Paiva; Figueira, Fernando Augusto Marinho dos Santos; Lima, George Augusto da Fonseca Carvalho Antunes.
Título: Embolization by Bullet Dislodged from the Heart
Fonte: Rev. bras. cir. cardiovasc = Braz. j. cardiovasc. surg. (impr.);32(6):539-541, Nov.-Dec. 2017. tab, graf.
Idioma: en.
Resumo: Abstract Embolization by a dislodged projectile is a rare complication that may occur in cases of gunshot cardiac injuries. We report a case of a firearm projectile cardiac injury that evolved, with dislocation of the projectile during cardiac surgery, into embolization of the right external carotid artery.
Descritores: Ferimentos por Arma de Fogo/complicações
Migração de Corpo Estranho/complicações
Embolia/etiologia
Traumatismos Cardíacos/complicações
-Ferimentos por Arma de Fogo/cirurgia
Ferimentos por Arma de Fogo/diagnóstico por imagem
Angiografia
Fluoroscopia
Migração de Corpo Estranho/cirurgia
Migração de Corpo Estranho/diagnóstico por imagem
Embolia/diagnóstico por imagem
Embolização Terapêutica/métodos
Traumatismos Cardíacos/cirurgia
Traumatismos Cardíacos/diagnóstico por imagem
Procedimentos Cirúrgicos Cardíacos/métodos
Limites: Humanos
Masculino
Adulto
Tipo de Publ: Relatos de Casos
Responsável: BR1.1 - BIREME


  8 / 127 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Chile
Texto completo
Id: lil-764073
Autor: Bernuy P, Sandra; Rivera N, María Cristina; Salazar L, Carmen; Ramírez C, Fernando.
Título: Dispositivo intrauterino parcialmente migrado e incrustado en serosa de rectosigmoides tras 8 años de inserción / Partially migrated intrauterine device embedded in the rectosigmoid serosa after 8 years of insertion
Fonte: Rev. chil. obstet. ginecol;80(5):412-415, ago. 2015. ilus.
Idioma: es.
Resumo: Se presenta el caso clínico de un dispositivo intrauterino parcialmente migrado a cavidad pélvica e incrustado en serosa de rectosigmoides luego de 8 años de su inserción. El diagnóstico se realizó mediante ecografía transvaginal y retiro del dispositivo por laparoscopia. Se realizó rafia de serosa rectal y de útero. La paciente tuvo un postoperatorio sin complicaciones.

It is shown the clinical case of an intrauterine device partially migrated to the pelvic cavity and embedded in the serous rectosigmoid eight years after insertion. The diagnosis was made by transvaginal ultrasound and laparoscopy removal of the device by laparoscopy. Suture of rectum serous and uterus were performed. The patient had an uneventful postoperative course.
Descritores: Migração de Corpo Estranho/diagnóstico por imagem
Migração de Dispositivo Intrauterino/efeitos adversos
-Reto/cirurgia
Reto/lesões
Membrana Serosa
Colo Sigmoide/cirurgia
Colo Sigmoide/lesões
Migração de Corpo Estranho/cirurgia
Ultrassonografia
Laparoscopia
Remoção de Dispositivo
Limites: Humanos
Feminino
Adulto
Tipo de Publ: Relatos de Casos
Responsável: CL1.1 - Biblioteca Central


  9 / 127 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Chile
Texto completo
Id: lil-747539
Autor: Bravo A, Coral; Sánchez R, Cristina; García A, María del Puerto; Pomares P, Ana; Segarra R, Julio.
Título: Dispositivo intrauterino migrado a la cavidad abdominal con embarazo intrauterino no evolutivo: reporte de caso / Intrauterine device migrated to the abdominal cavity with non-progressive intrauterine pregnancy: case report
Fonte: Rev. chil. obstet. ginecol;80(2):161-165, abr. 2015. ilus.
Idioma: es.
Resumo: La migración de un dispositivo intrauterino a la cavidad abdominal es una complicación poco frecuente de este eficaz método contraceptivo, sin embargo debe sospecharse ante la imposibilidad de visualizar los hilos del dispositivo vía vaginal y la ausencia intrauterina del mismo por ecografía. Si bien la migración abdominal puede ser asintomática, algunos casos pueden producir clínica de severidad variable incluyendo dolor abdominal y complicaciones derivadas de la formación de adherencias o la perforación de vísceras pélvicas y abdominales. Su detección intraabdominal debe sospecharse en primer lugar por ecografía y confirmarse mediante radiología simple de abdomen. Una vez localizado el dispositivo migrado, se recomienda su extracción inmediata, incluso en casos asintomáticos, con el fin de evitar las complicaciones derivadas de su desplazamiento. La laparoscopia será de primera elección en estos casos para la extracción. Presentamos un caso de migración intraabdominal de dispositivo intrauterino concurrente a un embarazo intrauterino no evolutivo.

Migration of an intrauterine device to the abdominal cavity is a rare complication of this effective contraceptive method, however, it must be suspected upon the inability to visualize the wires vaginally and the absence of intrauterine device by ultrasound. While its abdominal migration can be asymptomatic, some cases may produce variable clinical severity including abdominal pain and complications resulting from the formation of adhesions or perforation of pelvic and abdominal viscera. Its intraabdominal detection should be suspected first by ultrasound and confirmed by plain abdominal X-ray. Once the migrated device is located, immediate removal is recommended, even in asymptomatic cases, in order to avoid complications arising from its displacement. Laparoscopy will be the first choice in these cases for extraction. We report a case of intraabdominal migration of intrauterine device concurrent with a non-evolutive intrauterine pregnancy.
Descritores: Migração de Corpo Estranho/cirurgia
Cavidade Abdominal
Migração de Dispositivo Intrauterino/efeitos adversos
-Perfuração Uterina/cirurgia
Perfuração Uterina/etiologia
Migração de Corpo Estranho/diagnóstico por imagem
Laparoscopia
Remoção de Dispositivo
Limites: Humanos
Feminino
Gravidez
Adulto
Tipo de Publ: Relatos de Casos
Responsável: CL1.1 - Biblioteca Central


  10 / 127 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Saúde Pública
Texto completo
Id: biblio-890172
Autor: Oliveira, Cheila Gonçalves de; Rodas, Andrea Cecilia Dorion.
Título: Tecnovigilância no Brasil: panorama das notificações de eventos adversos e queixas técnicas de cateteres vasculares / Postmarketing surveillance in Brazil: vascular catheters - an overview of notifications of adverse events and technical complaints
Fonte: Ciênc. Saúde Colet;22(10):3247-3257, Out. 2017. tab, graf.
Idioma: pt.
Resumo: Resumo O objetivo deste artigo é identificar, quantificar e categorizar a ocorrência de notificações de eventos adversos e queixas técnicas relacionados ao uso de cateter vascular recebidas pelo sistema NOTIVISA no período de janeiro de 2007 a junho de 2016. Estudo descritivo, retrospectivo, documental, com abordagem quantitativa. Os dados solicitados e fornecidos pela Anvisa foram analisados e apresentados na forma de gráficos e tabelas. Fizeram parte do estudo 4682 notificações de queixas técnicas e 671 de eventos adversos. Houve aumento progressivo das notificações no período estudado. Quanto ao tipo de queixa técnica, a maioria delas se referiu a 'produto com suspeita de desvio de qualidade' sendo em maior quantidade o motivo 'rompimento do cateter durante o procedimento'. O evento adverso mais notificado foi 'Cateter rompeu na veia e migrou para outra parte do corpo'. Destaca-se que no período estudado ocorreram 4 notificações de óbitos, a forma mais grave de evento adverso. O estudo permitiu visualizar a importância da vigilância pós-comercialização dos cateteres vasculares além de fornecer um panorama de seu uso, o que pode apoiar ações de Tecnovigilância e subsidiar as políticas públicas voltadas a esse produto.

Abstract This article identifies, quantifies and categorizes adverse event notifications and technical complaints related to the use of vascular catheters, received by the Notivisa system in the period from January 2007 to June 2016. It is a descriptive, retrospective, documental study with a quantitative approach. Data requested and supplied by Anvisa were analyzed and presented in the form of charts and tables. The study covered 4,682 notifications of technical complaints, and 671 adverse events. There was a progressive increase in notifications during the period studied. As to the type of technical complaint, the majority referred to 'suspected quality failings', the largest component being due to 'catheter rupture during procedure'. The adverse event most notified was 'catheter broke in the vein and migrated to another part of the body'. In the period studied there were four notifications of deaths, the most severe level of adverse event. The study made it possible to visualize the importance of after-sales surveillance of vascular catheters, as well as supplying a wide-ranging overview of their use. Provision of this overview could support technical surveillance activities and serve as input for public policies relating to this product.
Descritores: Vigilância de Produtos Comercializados
Migração de Corpo Estranho/epidemiologia
Cateteres/efeitos adversos
-Brasil/epidemiologia
Estudos Retrospectivos
Falha de Equipamento
Limites: Humanos
Responsável: BR1.1 - BIREME



página 1 de 13 ir para página                         
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde