Id: biblio-1145300
Autor: Mackenney-Palamara, María; Sarmiento-Cornejo, Jaime.
Título: Evaluation of intensity standards of tungsten-halogen and led curing units / Evaluación de estándares de intensidad de unidades de curado tugsteno-halógenas y leds
Fonte: J. oral res. (Impresa);8(2):104-107, abr. 30, 2019. tab.
Idioma: en.
Resumo: Current evidence indicates that the minimum light intensity of photo curing units required to polymerize in a reliable way a composite resin, in increments of 2mm, is 300mW/cm2. The recent introduction of new generations of composite resin materials for large volume increments, partially contrasts with ISO 4049 (2009), calling for the use of light intensity of 1,000mW/cm2. Therefore, it is considered relevant to carry out periodic measurements of the emission intensity of light-curing units of clinical use. The aim of this study was to test the intensity [mW/cm2] of a representative sample of tungsten-halogen and LED photopolymerization units used in private and public health service in different areas of the Valparaíso Region in Chile. This was achieved through the use of dental radiometers, without considering the variables of intensity modification over time (either spontaneously, by undesirable inherent characteristics of the device, or by programs of intensity modification in time), or the density of accumulated power needed. This in vitro diagnostic test, evaluated a sample of 507 units, 107 halogen and 400 LED, for a period of around one month, using two radiometers as measuring instruments. For LED units the Bluephase Meter® radiometer, from Ivoclar-VivadentTM was used, and for halogen units we used the Coltolux® from ColténeTM. As a result, 85% of the LED and halogen units achieved the minimum requirements of intensity needed for the polymerization of conventional dental biomaterials. However, only 25% from the tested units achieved a power density of 1,000mW/cm2.
Descritores: Tecnologia Odontológica/instrumentação
Resinas Compostas/efeitos da radiação
Equipamentos Odontológicos
-Radiometria
Chile
Halogênios
Luz
Limites: Humanos
Responsável: CL30.1 - Biblioteca


  2 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Id: biblio-1018774
Autor: Centurión Ortiz, Teresa Fabiana.
Título: Desinfectantes en el consultorio odontológico: halógenos, aldehídos, fenólicos / Disinfectants in the dental office: halogens, aldehydes, phenolic.
Fonte: Asunción; s.e; 20041000. 41 p. ilus.
Idioma: es.
Resumo: Lo agentes antimicrobianos son ampliamente usados en el consultorio odontológico. Estos antimicrobianos se desarrollan cada día más, para elegir el que realmente será de utilidad, sin dañar al equipo, instrumentales pero sobre todo para no lastimar al paciente, se los deben conocer y manejarlos correctamente. La intención de este trabajo es describir agentes antimicrobianos de acción no selectiva específicamente para ser usados como agentes de desinfección, especialmente los objetos inanimados y mencionando el posible uso como agentes antisépticos. Se describirán los agentes desinfectantes de conocida efectividad, por ellos se limitarán a escribir las familias de los halógenos, fenólicis y aldehídos, sustancias que en la actualidad, son de mayor reconocimiento como agentes antimicrobianos.
Descritores: Aldeídos/administração & dosagem
Desinfecção/métodos
Farmacologia
Fenóis/administração & dosagem
Halogênios/administração & dosagem
Odontologia
Limites: Humanos
Tipo de Publ: Revisão
Responsável: PY8.1 - Biblioteca
PY8.1; 617.6, C43d


  3 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Marinho, Vitor Alexandre
Barros, Letízia Monteiro de
Id: biblio-873776
Autor: Fritas, Amanda Beatriz Dahadah Aniceto de; Gomes, Hugo Rocha; Guimarães, Fabrício Barbosa Rocha; Marinho, Vitor Alexandre; Barros, Letízia Monteiro de.
Título: Influência do tipo de aparelho fotopolimerizador na absorção de água por restaurações de resina composta / Influence of the type of light-curing unit on the water sorption of composites
Fonte: J. Health Sci. Inst = Rev. Inst. Ciênc. Saúde;26(1):65-69, jan.-mar. 2008. tab.
Idioma: pt.
Resumo: Introdução - O objetivo deste estudo foi verificar a influência do tipo de aparelho fotoativador na absorção de água por restaurações de uma marca comercial de resina composta. Corpos-de-prova cilíndricos foram cofeccionados com uma resina composta micro-híbrida (Z250, 3M ESPE), que foram agrupados considerando o aparelho fotopolimerizador. Material e Métodos - Foram utilizados 3 aparelhos com diodos emissores de luz, LEDs (2 aparelhos de baixa e 1 de alta potência) e 1 aparelho halógena. A quantidade de água absorvida foi medida por variação de massa, sendo os espécimes pesados, em balança de precisão, imediatamente, a cada 24h por 8 dias, e após 15, 30 e 60 dias de sua confecção. Entre as pesagens, os espécimes foram mantidos em água a 37?C. Os dados obtidos foram submetidos à Análise de Variância 2 critérios (p = 0,00230. Resultados - As diferenças na absorção de água entreos grupos foram analisados pelo teste de Tukey. Foi observada diferença significativa entre o grupo da luz halógena e os LEDs de baixa potência, e entre estes e o LED de alta potência. O teste de student-Newman-Keuls foi utilizado para detectar diferença dentro de cada grupo. Nenhuma diferença significativa foi encontrada nos grupos do aparelho de luz halógena e do LED de alta potência: nos grupos dos LEDs de baixa potência foram obsevadas diferenças significativas nos diversos tempos de pesagem. Conclusão - Concluiu-se que os aparelhos de luz halógena e o LED de alta potência proporcionaram melhor polimerização e, com isso, menor absorção deágua significando, clinicamente, melhores propriedades e maior longevidade da restauração.
Descritores: Resinas Compostas
Halogênios
Luz
-Absorção
Restauração Dentária Permanente
Água
Tipo de Publ: Estudo Comparativo
Responsável: BR12.1 - Biblioteca Setorial da Ciências da Saúde


  4 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Magalhäes, Cláudia Silami de
Texto completo
Id: lil-769553
Autor: Pereira, Carolina Nemesio de Barros; Magalhães, Cláudia Silami de; Daleprane, Bruno; Peixoto, Rogéli Tibúrcio Ribeiro da Cunha; Ferreira, Raquel da Conceição; Cury, Luiz Alberto; Moreira, Allyson Nogueira.
Título: LED and Halogen Light Transmission through a CAD/CAM Lithium Disilicate Glass-Ceramic
Fonte: Braz. dent. j;26(6):648-653, Nov.-Dec. 2015. tab, graf.
Idioma: en.
Resumo: The effect of thickness, shade and translucency of CAD/CAM lithium disilicate glass-ceramic on light transmission of light-emitting diode (LED) and quartz-tungsten-halogen units (QTH) were evaluated. Ceramic IPS e.max CAD shades A1, A2, A3, A3.5, high (HT) and low (LT) translucency were cut (1, 2, 3, 4 and 5 mm). Light sources emission spectra were determined. Light intensity incident and transmitted through each ceramic sample was measured to determine light transmission percentage (TP). Statistical analysis used a linear regression model. There was significant interaction between light source and ceramic translucency (p=0.008) and strong negative correlation (R=-0.845, p<0.001) between ceramic thickness and TP. Increasing one unit in thickness led to 3.17 reduction in TP. There was no significant difference in TP (p=0.124) between shades A1 (ß1=0) and A2 (ß1=-0.45) but significant reduction occurred for A3 (ß1=-0.83) and A3.5 (ß1=-2.18). The interaction QTH/HT provided higher TP (ß1=0) than LED/HT (ß1=-2.92), QTH/LT (ß1=-3.75) and LED/LT (ß1=-5.58). Light transmission was more effective using halogen source and high-translucency ceramics, decreased as the ceramic thickness increased and was higher for the lighter shades, A1 and A2. From the regression model (R2=0.85), an equation was obtained to estimate TP value using each variable ß1 found. A maximum TP of 25% for QTH and 20% for LED was found, suggesting that ceramic light attenuation could compromise light cured and dual cure resin cements polymerization.

Resumo Avaliou-se o efeito da espessura, cor e translucidez de uma cerâmica vítrea a base de dissilicato de lítio para CAD / CAM sobre a transmissão da luz de unidades de diodos emissores de luz (LED) e de quartzo-tungstênio-halogênio (QTH). Cerâmica IPS e.max CAD nas cores A1, A2, A3, A3.5 de translucidez alta (HT) e baixa (LT) foram cortadas (1, 2, 3, 4, 5 mm). Os espectros de emissão das fontes de luz foram determinados. A intensidade da luz incidente e transmitida através de cada espécime de cerâmica foi medida para determinar a percentagem de transmissão de luz (TP). Um modelo de regressão linear foi utilizado para a análise estatística. Houve interação significativa entre a fonte de luz e translucidez cerâmica (p = 0.008) e forte correlação negativa (r = -0.845, p <0.001) entre a espessura da cerâmica e TP. O aumento da espessura em uma unidade levou a uma redução média de 3.17 em TP. Não houve diferença significativa em TP (p = 0.124) entre as cores A1 (ß1 = 0) e A2 (ß1 = -0.45), mas ocorreu redução significativa para as cores A3 (ß1 = -0.83) e A3.5 (ß1 = -2.18). A interação QTH/HT proporcionou maior TP (ß1 = 0) do que LED/HT (ß1 = -2.92), QTH/LT (ß1 = -3.75) e LED/LT (ß1 = -5.58). A transmissão de luz foi mais eficaz utilizando QTH e cerâmica de alta translucidez, diminuiu à medida que a espessura de cerâmica aumentou, e foi maior para as cores A1 e A2. A partir do modelo de regressão (R2 = 0.85), obteve-se uma equação para estimar o valor de TP utilizando os valores de ß1 encontrado. Foi observada TP máxima de 25% para QTH e 20% para LED, sugerindo que a atenuação promovida pela cerâmica pode comprometer a ativação de um cimento resinoso fotoativado e de ativação dupla.
Descritores: Cerâmica
Desenho Assistido por Computador
Porcelana Dentária/química
Vidro
Halogênios
Luz
Responsável: BR1.1 - BIREME


  5 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Balducci, Ivan
Texto completo
Id: lil-541954
Autor: Firoozmand, Leily Macedo; Balducci, Ivan; Araujo, Maria Amélia Máximo de.
Título: Influência da fotopolimerização e da cor da resina composta na microdureza / Influence of light curing and shade on the microhardness of a composite resin
Fonte: Pesqui. bras. odontopediatria clín. integr;9(1):37-42, jan.-abr. 2009. graf.
Idioma: pt.
Resumo: Objetivo: Verificar a influência da opacidade de cor e tipos de aparelhos fotopolimerizadores (luz halogena X led azul) na microdureza da resina composta. Método: A resina composta Esthet-X (Dentsply), nas cores A2 e A2-O, foi inserida em uma matriz de aço-inoxidável com cavidades de 5mm de diâmetro e 2mm de profundidade e fotopolimerizadas por aparelhos; de luz halógena, XL 3000 (3M) ou de LED azul, Optilight LD II (Gnatus), por 40s. Formaram-se 8 grupos com quinze amostras cada, sendo estes divididos conforme as fontes polimerizadoras utilizadas, a área de exposição (superfície e a base) e a opacidade da resina composta empregada, perfazendo um total de 120 amostras de estudo. Estas foram armazenadas em água destilada, por 24h e embutidas em resina acrílica ativada quimicamente (RAAQ), sendo posteriormente realizados o acabamento e polimento com discos de lixa e de feltro. Realizou-se a leitura da microdureza em Microdurômetro Digital Vickers, utilizando 50g de carga por 30s de permanência. As médias das amostras foram submetidas aos testes estatísticos de análise de variância (ANOVA) e ao teste de comparação múltipla de Tukey (5%). Resultados: A microdureza da superfície foi sempre maior que a da base independente do aparelho polimerizador utilizado; o aparelho de luz halógena apresentou maiores valores médios de microdureza da resina composta (57,61HV) em relação ao aparelho de LED (42,53HV); foram encontradas diferenças significantes entre os valores médios de microdureza ao se variar a opacidade, sendo que em profundidade obteve-se os menores valores com a resina A2-O. Conclusão: A opacidade da resina, bem como, o aparelho fotopolimerizador influenciam no grau de microdureza da resina composta.
Descritores: Resinas Compostas
Materiais Dentários
Halogênios/química
Luz/efeitos adversos
Restauração Dentária Permanente/métodos
Testes de Dureza/métodos
-Análise de Variância
Tipo de Publ: Estudo de Avaliação
Responsável: BR1264.1 - Biblioteca Setorial Prof Alberto M Campos


  6 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Lauris, José Roberto Pereira
Texto completo
Id: lil-514024
Autor: Cefaly, Daniela Francisca Gigo; Mello, Liliam Lucia Carrara Paes de; Wang, Linda; Lauris, José Roberto Pereira; D'Alpino, Paulo Henrique Perlatti.
Título: Effect of light curing unit on resin-modified glass-ionomer cements: a microhardness assessment
Fonte: J. appl. oral sci;17(3):150-154, May-June 2009. tab.
Idioma: en.
Resumo: OBJECTIVE: To evaluate the microhardness of resin-modified glass-ionomer cements (RMGICs) photoactivated with a blue light-emitting diode (LED) curing light. MATERIAL AND METHODS: Thirty specimens were distributed in 3 groups: Fuji II LC Improved/GC (RM1), Vitremer/3M ESPE (RM2) and Filtek Z250/ 3M ESPE (RM3). Two commercial light-curing units were used to polymerize the materials: LED/Ultrablue IS and a halogen light/XL3000 (QTH). After 24 h, Knoop microhardness test was performed. Data were submitted to three-way ANOVA and Tukey's test at a pre-set alpha of 0.05. RESULTS: At the top surface, no statistically significant difference (p>0.05) in the microhardness was seen when the LED and QTH lights were used for all materials. At the bottom surface, microhardness mean value of RM2 was significantly higher when the QTH light was used (p<0.05). For RM1, statistically significant higher values (p<0.05) were seen when the LED light was used. No statistically significant difference (p>0.05) was seen at the bottom surface for RM3, irrespective of the light used. Top-to-bottom surface comparison showed no statistically significant difference (p>0.05) for both RMGICs, regardless of the light used. For RM3, microhardness mean value at the top was significantly higher (p<0.05) than bottom microhardness when both curing units were used. CONCLUSION: The microhardness values seen when a LED light was used varied depending on the restorative material tested.
Descritores: Luzes de Cura Dentária
Cimentos de Ionômeros de Vidro/efeitos da radiação
-Resinas Compostas/efeitos da radiação
Cimentos de Ionômeros de Vidro/química
Halogênios
Dureza
Cura Luminosa de Adesivos Dentários
Teste de Materiais
Resinas Sintéticas/efeitos da radiação
Semicondutores
Propriedades de Superfície
Tipo de Publ: Estudo Comparativo
Estudo de Avaliação
Responsável: BR1.1 - BIREME


  7 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-513914
Autor: Silva, Cecy Martins; Dias, Katia Regina Hostilio Cervantes.
Título: Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED
Fonte: Braz. dent. j;20(1):54-57, 2009. tab.
Idioma: en.
Resumo: This study compared the compressive strength of a composite resin and compomer photoactivated with a conventional quartz-tungsten halogen-light (XL 3000, 3M/SPE) and a blue light-emitting diode (LED) (SmartLite PS; Dentsply/De Trey). Forty disc-shaped specimens were prepared using a split polytetrafluoroethylene matrix (4.0 mm diameter x 8.0 mm hight) in which the materials were inserted incrementally. The curing time of each increment was of 40 s with the QTH and 10 s with the LED. The specimens were randomly assigned to 4 groups (n=10), according to the light source and the restorative material. After storage in distilled water at 37oC ± 2oC for 24 h, the specimens was tested in compressive strength in a universal testing machine with load cell of 500 kgf running at a crosshead speed of 0.5 mm/min. Data (in MPa) were analyzed statistically by ANOVA and Student-Newman-Keuls test (p<0.05). For the composite resin, light curing with the QTH source did not produce statistically significant difference (p>0.05) in the compressive strength when compared to light curing with the LED source. However, light curing of the compomer with the QTH source resulted in significantly higher compressive strength than the use of the LED unit (p>0.05). The composite resin presented significantly higher (p>0.05) compressive strength than the compomer, regardless of the light source. In conclusion, the compressive strength of the tested materials photoactivated with a QTH and a LED light source was influenced by the energy density employed and the chemical composition of the esthetic restorative materials.

Este estudo comparou a resistência à compressão de uma resina composta e de um compômero, fotoativados com luz halógena convencional de quarto-tungstênio (QTH) (XL 300, 3M/SPE) e LED azul (SmartLite PS; Dentsply/De Trey). Foram confeccionados 40 espécimes em forma de disco usando uma matriz bipartida de politetrafluoretileno (4,0 mm de diâmetro x 8,0 mm de altura) em que o material foi inserido incrementalmente. O tempo de polimerização de cada incremento foi de 40 s para a luz halógena convencional e de 10 s para o LED. Os espécimes foram aleatoriamente alocados em 4 grupos (n=10), de acordo com a fonte de luz e com o material restaurador. Depois de armazenadas em água destilada a 37°C ± 2°C por 24 h, a resistência à compressão dos espécimes foi testada em uma máquina universal de ensaios com célula de carga de 500 kgf a uma velocidade de carregamento de 0,5 mm/min. Os dados (em MPa) foram analisados estatisticamente por ANOVA e teste de Student-Newman-Keuls (p<0,05). Para a resina composta, a fotopolimerização com luz halógena não produziu diferença estatisticamente significante (p>0,05) em sua resistência à compressão quando comparada à fotopolimerização com LED. Contudo, a fotopolimerização do compômero com a luz halógena resultou em uma resistência à compressão significativamente maior que a feita o LED (p>0,05). A resina composta apresentou resistência à compressão significativamente maior que a do compômero, independente da fonte de luz. Concluiu-se que a resistência à compressão dos materiais fotopolimerizados com luz halógena e LED foi influenciada pela densidade de energia empregada e pela composição química dos materiais restauradores estéticos.
Descritores: Luzes de Cura Dentária
Compômeros/efeitos da radiação
Resinas Compostas/efeitos da radiação
Cura Luminosa de Adesivos Dentários/métodos
-Força Compressiva/efeitos da radiação
Análise do Estresse Dentário
Halogênios
Distribuição Aleatória
Semicondutores
Tipo de Publ: Estudo Comparativo
Estudo de Avaliação
Responsável: BR1.1 - BIREME


  8 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-502765
Autor: Lopes, Lawrence Gonzaga; Jardim Filho, Alfeu da Veiga; Souza, João Batista de; Rabelo, Denilson; Franco, Eduardo Batista; Freitas, Gersinei Carlos de.
Título: Influence of pulse-delay curing on sorption and solubility of a composite resin
Fonte: J. appl. oral sci;17(1):27-31, Jan.-Feb. 2009. tab.
Idioma: en.
Resumo: The purpose of this study was to evaluate the sorption and solubility of a composite resin (TPH³; Dentsply) cured with halogen light due to different storage media and curing modes. The methodology was based on the ISO 4049 standard. Two independent groups were established according to the storage time (7 days-G1; 60 days-G2). A stainless steel mould (2 mm x 8 mm Ø) was used. The selected curing modes were: I (Conventional - C): 40s - 600 mW/cm²; II (Pulse I - PD): 3 s - 200 mW/cm² + 2 min (delay) + 39 s - 600 mW/cm²; III (Pulse II): 10 s - 200 mW/cm² + 2 min (delay) + 37 s - 600 mW/cm²; IV (Pulse III): 3 s- 600 mW/cm² + 2 min (delay) + 37 s -600 mW/cm². The media used were: distilled water, 75 percent ethanol and 100 percent chlorophorm. Five repetitions were made for each group. The specimens were placed in a desiccator at 37ºC for 24 h and, after that, at 23ºC for 1 h to be weighed until a constant mass (m1) was obtained. The discs were immersed separately into the 3 media for 7 days (G1) and 60 days (G2), and thereafter reweighed (m2). The reconditioning in the desiccator was done until a constant mass (m3) was obtained. Sorption and solubility were calculated and the data of G1 and the sorption data of G2 were subjected to two-way ANOVA and Tukey's tests (p=0.05). The solubility data of G2 were analyzed by Kruskal-Wallis test (p=0.05). For G1 and G2, no statistically significant differences were found in sorption among curing techniques (p>0.05). The solubility values were negative, which means that there was mass gain. Regarding the storage media, in G2 chlorophorm had the highest sorption values. It may be concluded that the curing modes (C and PD I, II and III) did not affect the sorption of the tested composite resin. However, different storage media influenced sorption behavior. The solubility test demonstrated negative data, masking the real solubility.
Descritores: Resinas Compostas/efeitos da radiação
Cura Luminosa de Adesivos Dentários/métodos
-Absorção
Clorofórmio
Luzes de Cura Dentária
Resinas Compostas/química
Etanol
Halogênios
Dureza
Teste de Materiais
Nanocompostos/química
Nanocompostos/efeitos da radiação
Transição de Fase
Solventes
Água
Responsável: BR1.1 - BIREME


  9 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-495141
Autor: Carrasco, Thaise Graciele; Carrasco-Guerisoli, Laise Daniela; Frõner, Izabel Cristina.
Título: In vitro study of the pulp chamber temperature rise during light-activated bleaching
Fonte: J. appl. oral sci;16(5):355-359, Sept.-Oct. 2008. ilus, tab.
Idioma: en.
Resumo: This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35 percent hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1 percent significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38±0.66ºC). The LED unit produced the lowest temperature increase (0.29±0.13ºC); but there was no significant difference between LED unit and LED-laser system (0.35±0.15ºC) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41±0.64ºC), and LED-laser system the lowest (0.33±0.12ºC); however, there was no difference between LED-laser system and LED unit (0.44±0.11ºC). LED and LED-laser ...
Descritores: Temperatura Corporal
Polpa Dentária/fisiologia
Luz/efeitos adversos
Clareamento Dental/efeitos adversos
-Luzes de Cura Dentária
Halogênios
Peróxido de Hidrogênio/efeitos da radiação
Incisivo
Lasers
Oxidantes/efeitos da radiação
Semicondutores
Limites: Humanos
Responsável: BR1.1 - BIREME


  10 / 29 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Alonso, Roberta Caroline Bruschi
Sinhoreti, Mário Alexandre Coelho
Texto completo
Id: lil-486494
Autor: Cunha, Leonardo Gonçalves; Alonso, Roberta Caroline Bruschi; Souza-Junior, Eduardo José Carvalho de; Neves, Ana Christina Elias Claro; Correr-Sobrinho, Lourenço; Sinhoreti, Mário Alexandre Coelho.
Título: Influence of the curing method on the post-polymerization shrinkage stress of a composite resin
Fonte: J. appl. oral sci;16(4):266-270, July-Aug. 2008. ilus, tab.
Idioma: en.
Resumo: The aim of this study was to evaluate the effect of different curing methods on the stress generated by the polymerization shrinkage of a restorative composite in two moments: immediately after light exposure and after 5 min. Photoactivation was performed using two different light sources: (1) xenon plasma arc (PAC) light (1,500 mW/cm2 - 3s) and (2) a quartz-tungsten-halogen (QTH) light with three light-curing regimens: continuous exposure (40 s at 800 mW/cm2 - CL); soft-start (10 s at 150 mW/cm2 and 30 s at 800 mW/cm2 - SS) and intermittent light [cycles of 4 s (2 s with light on at 600 mW/cm2 and 2 s of light off), for 80s - IL]. The composite resin was applied between two 5-mm diameter metallic rods, mounted in a servohydraulic machine. The maximum stress was recorded immediately after light exposure (FF) and after 5 min (5F). The results were submitted to ANOVA and Tukey's test (5 percent). For each method, the results obtained in FF and 5F were, respectively: CL (3.58 and 4.46 MPa); SS (2.99 and 4.36 MPa); IL (3.11 and 4.32 MPa) and PAC (0.72 and 3.27 MPa). The stress generated by the polymerization shrinkage during light exposure can be associated with the photoactivation method used. A significant increase in the stress level was observed during the post-curing period up to 5 min, for all evaluated methods.
Descritores: Resinas Compostas/efeitos da radiação
Análise do Estresse Dentário
Cura Luminosa de Adesivos Dentários/métodos
Cimentos de Resina/efeitos da radiação
-Luzes de Cura Dentária
Halogênios
Teste de Materiais
Transição de Fase
Fatores de Tempo
Xenônio
Responsável: BR28.1 - Serviço de Biblioteca e Documentação Professor Doutor Antônio Gabriel Atta



página 1 de 3 ir para página          
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde