Base de dados : LILACS
Pesquisa : D01.362 [Categoria DeCS]
Referências encontradas : 126 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 13 ir para página                         

  1 / 126 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-1001901
Autor: Costa Jr, Altair da Silva; Miotto, Andre; Paulo, Gustavo Andrade de; Ferrari, Angelo Paulo; Ota, Luiz Hirotoshi.
Título: Experimental study for evaluation of a low-cost spray cryotherapy system / Estudo experimental para avaliação de um sistema de baixo custo para crioterapia em spray
Fonte: Einstein (Säo Paulo);17(2):eAO4533, 2019. graf.
Idioma: en.
Resumo: ABSTRACT Objective To evaluate the feasibility and applicability of a low-cost cryotherapy system. Methods Experimental study with 25kg Landrace pigs submitted to a longitudinal cervico-thoraco-abdominal incision for exposure of the trachea, thorax and abdomen. The tissues were frozen by continuous spray application at different periods of time (5, 10 and 15 seconds). Spray cryotherapy was performed using a fluorinated gas (tetrafluorethane) delivered at - 47°C temperature (DermaFreeze®, Emdutos; ANVISA registration 80409950001; price R$ 394,00). via an adapted, disposable 1.8mm cholangiography catheter (Olympus; price R$ 280,00). The specimens were resected for histopathological analysis. Results Thirty samples were obtained from ten different organs and divided according to spray cryotherapy application time. System activation for 5, 10 or 15 seconds led to consumption of 14g, 27g and 40g of gas respectively (average gas consumption, 2.7g/s using a 1.8mm catheter). The system comprising a spray tube and catheter proved user-friendly and effective, with constant gas dispersion and adequate tissue freezing. In spite of effective freezing, microscopy failed to reveal tissue changes. This may have reflected methodological constraints precluding evaluation at tissue damage peak time (48 hours). Conclusion The low-cost spray cryotherapy system proved feasible and safe.

RESUMO Objetivo Avaliar a exequibilidade e a aplicação de um sistema de baixo custo de crioterapia. Métodos Estudo experimental realizado com um suíno da raça Landrace, 25kg, submetido à cervicotoracolaparotomia longitudinal, com exposição de traqueia, tórax e abdome. Procedemos ao congelamento das estruturas em tempos diferentes (5, 10 e 15 segundos) com jato contínuo. A crioterapia foi realizada com gás fluoretado (tetrafluoretano), na forma de spray em tubo, que atinge a temperatura de -47°C (DermaFreeze®, Emdutos; registro ANVISA 80409950001; preço R$ 394,00). A este tubo, adaptamos um cateter descartável de colangiografia de 1,8mm (Olympus; preço R$ 280,00). As peças foram ressecadas para análise histopatológica. Resultados Foram obtidas 30 amostras em 10 órgãos diferentes, divididos em três intervalos de tempo distintos. Quando o sistema foi acionado por 5 segundos, gastaram-se 14g de gás; por 10 segundos, 27g; e por 15 segundos, 40g; o gasto médio foi de 2,7g/s pelo cateter de 1,8mm. O sistema confeccionado com tubo de gás e cateter proporcionou resultado efetivo, com dispersão adequada e constante do gás, congelamento adequado e de fácil execução. Apesar da técnica evidenciar congelamento efetivo, na microscopia não houve alteração tecidual. Isso ocorreu porque o pico de lesão tecidual por congelamento ocorre após 48 horas, o que não foi possível avaliar por este método proposto. Conclusão O sistema de crioterapia em spray de baixo custo foi exequível e seguro.
Descritores: Crioterapia/métodos
Gases/farmacologia
-Suínos
Fatores de Tempo
Reprodutibilidade dos Testes
Crioterapia/economia
Crioterapia/instrumentação
Cateteres
Congelamento
Limites: Animais
Tipo de Publ: Estudo de Avaliação
Responsável: BR1.1 - BIREME


  2 / 126 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-1251546
Autor: Camargo, Nataly; Benavides, María Alejandra; Parra-Medina, Rafael; Pérez, Cristian.
Título: Neumatosis quística intestinal en un adulto joven sin antecedentes clínicos: reporte de caso / Cystic intestinal pneumatosis in a young adult with no clinical history: Case report
Fonte: Rev. colomb. gastroenterol;36(supl.1):47-51, abr. 2021. graf.
Idioma: es.
Resumo: Resumen La neumatosis quística intestinal se refiere a la presencia de gas dentro de la pared del intestino delgado o grueso, puede ser asintomática y potencialmente mortal cuando se presentan complicaciones. Las causas de esta entidad incluyen enfermedades pulmonares, sistémicas, intestinales, medicamentosas, causas iatrogénicas y traumáticas. Se presenta el caso de un hombre de 35 años de edad sin antecedentes de importancia que consultó por dolor en el hemiabdomen inferior, con un diagnóstico imagenológico de neumatosis quística intestinal, neumoperitoneo y peritonitis, complicación secundaria a esta patología, por lo que se realizó el manejo quirúrgico, laparotomía y resección de segmento colónico, que se analizó histopatológicamente y se confirmó el diagnostico; finalmente, fue dado de alta después de finalizar el tratamiento antibiótico.

Abstract Cystic intestinal pneumatosis refers to the presence of gas within the wall of the small or large intestine. It can be asymptomatic and life-threatening when complications occur. The causes of this entity include pulmonary, systemic, intestinal, drug, iatrogenic and traumatic factors. The following is the case of a 35-year-old man who presented with pain in his lower hemiabdomen and had no previous medical history. Imaging scans showed intestinal cystic pneumatosis and secondary pneumoperitoneum and peritonitis. The patient was taken to laparotomy, and a colonic segment was resected and sent to pathology. The diagnosis was confirmed by a biopsy. The patient was discharged after completing antibiotic treatment.
Descritores: Peritonite
Pneumatose Cistoide Intestinal
-Gases
Intestino Grosso
Intestino Delgado
Limites: Humanos
Masculino
Adulto
Tipo de Publ: Relatos de Casos
Responsável: CO354 - Sociedad Colombiana de Gastroenterología


  3 / 126 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Cuba
Texto completo
Texto completo
Id: biblio-1093814
Autor: Garmendia García, Fermín; Aget Rodríguez, Yulisleydi; Saquisili Reyes, Amanda; Gallo, Julián; Nieves Marrueta, Shein; Maquintoche, Jorge Luis.
Título: Aplicación del ozono interescalénico en la radiculopatía cervical por hernia discal / Application of intercalenic ozone in cervical radiculopathy due to herniated disc
Fonte: Rev. cuba. reumatol;21(2):e62, mayo.-ago. 2019. tab.
Idioma: es.
Resumo: Introducción: el ozono es un gas médico descrito desde el siglo XIX que ha tenido su evolución hasta a la fecha en cuanto a sus aplicaciones y su utilidad en diversas enfermedades por su actuación a nivel molecular y en disímiles enfermedades asociadas a procesos dolorosos de origen inflamatorio como los presentes en las hernia discales de la columna vertebral. Método: estudio retrospectivo con 20 pacientes atendidos en la consulta externa de Neurocirugía del Hospital Miguel Enríquez desde de Diciembre 2016 hasta Abril 2017 con el diagnostico de una radiculopatía cervical por hernia discal. Se le aplicó 10 ML de ozono con una concentración 22 mg/litro tres veces en la semana durante 10 semanas solamente se utilizó este tipo de terapia; obteniendo mejoría en 15 pacientes. Resultados: predominando los mayores de 51 años para un 50 por ciento, en nuestra serie predominó el sexo femenino para un 80 por ciento. En cuanto al cuadro clínico prevaleció la disminución de la fuerza muscular para un 60 por ciento en 12 pacientes, seguidos del dolor cervical y el interescapular para un 75 por ciento y 55 por ciento respectivamente. Se halló mejoría en 15 pacientes para un 75 por ciento y en los otros 5, en tres pacientes no continuaron el tratamiento y en dos no se obtuvo mejoría. Conclusiones: tenemos otra alternativa en la aplicación del ozono por el espacio interescalénico como tratamiento analgésicos y antiinflamatorio en las radiculopatía por hernia discales cervicales(AU)

Introduction: Ozone is a medical gas described since the nineteenth century that has had its evolution up to date in terms of its applications and its usefulness in various diseases for its performance at the molecular level and dissimilar diseases associated with painful processes of inflammatory origin such as those present in herniated discs of the spine. Method: Retrospective study with 20 patients assisted in the outpatient consultation of the Miguel Enríquez Hospital from December 2016 to April 2017 with the diagnosis of a cervical radiculopathy by herniated disc. 10 ML of ozone applied with a concentration of 22 mg/liter three times in the week for 10 weeks only this type of therapy used getting improvement in 15 patients. Results: predominating the older than 51 years for 50 percent, in our series predominated the female sex for 80 percent .As for the clinical picture, decreased muscle strength was prevailed for 60 percent in 12 patients, followed by cervical pain and interescapular for 75 percent and 55 percent respectively. We found improvement in 15 patients for 75 percent and in the other 5, in 3 patients did not continue the treatment and in two, no improvement obtained. Conclusions: We have another alternative in the application of ozone by the intercalenic space as analgesic and anti-inflammatory treatment in cervical herniated discus radiculopathy(AU)
Descritores: Pacientes Ambulatoriais
Encaminhamento e Consulta
Cervicalgia
Força Muscular/fisiologia
Gases/uso terapêutico
Analgésicos/uso terapêutico
Deslocamento do Disco Intervertebral/terapia
-Estudos Retrospectivos
Limites: Humanos
Pessoa de Meia-Idade
Idoso
Idoso de 80 Anos ou mais
Responsável: CU1.1 - Biblioteca Médica Nacional


  4 / 126 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-1130586
Autor: Bocio, Cleo Irene; García, Johana Aylen; Dotto, Gladys; Roch, Florencia Graciela; Neme Mazzuchi, Viviana Noelia; Jachuf, Carolina; Torres, María Lía.
Título: Comparación de dos tipos de recipientes para analizar gases en sangre y otras mediciones relacionadas contra jeringas con heparinato de litio liofilizado / Comparison of two types of containers to analyze blood gases and other related measurements against syringes with lyophilized lithium heparinate / Comparação de dois tipos de recipientes para analisar gases em sangue e outras medições relacionadas contra seringas com heparinato de lítio liofilizado
Fonte: Acta bioquím. clín. latinoam;54(2):117-124, jun. 2020. graf, tab.
Idioma: es.
Resumo: El estudio de gases en sangre involucra pruebas relacionadas con el equilibrio ácido-base y estado de oxigenación (pH, pO2, SO2, pCO2, HCO3 -). Además, en los equipos multiparamétricos se realizan otras determinaciones (mediciones relacionadas) como: Na+, K+, Cl-, Ca2+, glucosa y lactato. El objetivo de este trabajo fue comparar los resultados de medición de dos tipos de recipientes (tipo 2: jeringa preparada en el laboratorio con heparinato de Na+ líquido diluido y tipo 3: microtubo con heparinato de Li líquido) contra el recipiente recomendado por el CLSI en su guía 46-A2 (tipo 1: jeringa con heparinato de Li liofilizado balanceado con zinc). El análisis se hizo desde un punto de vista estadístico y clínico para establecer la posibilidad de usar indistintamente estos tres tipos de recipientes. Se analizaron un total de 254 muestras. Para evaluar la aceptación clínica de los resultados se tomó como estándar de calidad la variabilidad biológica. No se encontraron diferencias clínicamente significativas en los analitos del recipiente tipo 2 respecto del tipo 1, excepto para Ca2+. Se rechazaron desde el punto de vista clínico varios analitos del recipiente tipo 3. En conclusión, el uso del recipiente tipo 3 fue inapropiado. Sin embargo, el recipiente tipo 2 sería apto para el análisis de este tipo de muestras.

Blood gas analysis involves tests related to the acid-base balance and oxygenation state (pH, pO2, SO2, pCO2, HCO3 -). In multiparametric equipment, some ion and metabolite (related measurements) are performed: Na+, K+, Cl-, Ca²+, glucose and lactate. The objective of this study was to compare two types of containers (type 2: syringe prepared in the laboratory with diluted liquid sodium heparinate and type 3: microtube with liquid lithium heparinate) against the container recommended by CLSI in its guide 46-A2 (type 1: syringe with lyophilized lithium heparinate balanced with inc). The analysis was made from a statistical and clinical point of view to establish the possibility of indiscriminately using these three types of containers. A total of 254 samples were analyzed. To establish the clinical acceptance of the results, the biological variability quality standard was used. No clinically significant differences were found in the analytes of the type 2 container compared to type 1, except for Ca+. Several analytes of the type 3 container were rejected from the clinical point of view. In conclusion, the use of the type 3 container is inappropriate; however, the type 2 container would be suitable for the analysis of this type of samples.

O estudo de gases em sangue envolve testes relacionados com o equilíbrio ácido-base e estado de oxigenação (pH, pO2, SO2, pCO2, HCO3 -). Além disso, nos equipamentos multiparâmetros, outras determinações (medições relacionadas) como: Na+ , K+, Cl-, Ca2+, glicose e lactato são realizadas. O objetivo deste trabalho foi comparar os resultados de medição de dois tipos de recipientes (tipo 2: seringa preparada no laboratório com heparinato de Na+ líquido diluído e tipo 3: microtubo com heparinato de Li líquido) contra o recipiente recomendado pelo CLSI em seu guia 46-A2 (tipo 1: seringa com heparinato de Li liofilizado equilibrado com zinco). A análise foi feita do ponto de vista estatístico e clínico, para estabelecer a possibilidade de utilização indiscriminada desses três tipos de recipientes. Um total de 254 amostras foram analisadas. Para avaliar a aceitação clínica dos resultados, a variabilidade biológica foi tomada como padrão de qualidade. Não foram encontradas diferenças clinicamente significativas nos analitos do recipiente tipo 2 em relação ao tipo 1, exceto para Ca²+. Vários analitos do recipiente tipo 3 foram rejeitados do ponto de vista clínico. Em conclusão, o uso do contêiner tipo 3 foi inadequado. No entanto, o recipiente tipo 2 seria apto para a análise deste tipo de amostras.
Descritores: Seringas
Equilíbrio Ácido-Base
Gasometria
Gestão da Qualidade
Concentração de Íons de Hidrogênio
-Sódio
Zinco
Medidas, Métodos e Teorias
Sangue
Ácido Láctico
Estado
Equipamentos e Provisões
Gases
Glucose
Laboratórios
Limites: Humanos
Masculino
Feminino
Adulto
Pessoa de Meia-Idade
Idoso
Idoso de 80 Anos ou mais
Responsável: AR144.1 - CIBCHACO - Centro de Información Biomedica del Chaco


  5 / 126 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-1178823
Autor: Trigo Orsini, Myriam Lina.
Título: Validación del método para la cuantificación de alcohol en sangre por cromatografía gaseosa con detector de ionización de llama y espacio de cabeza y correlación con el método enzimático / Validation of the method for the quantification of blood alcohol by gaseous chromatography with flame ionization detector and head and correlation space with the enzymatic method
Fonte: Con-ciencia (La Paz);5(2):29-42, nov. 2017. il., tab..
Idioma: es.
Resumo: El presente estudio describe la estandarización del método para la cuantificación de alcohol en sangre por Cromatografía Gaseosa con Detector de Ionización de llama y espacio de cabeza. La separación del alcohol de una matriz compleja como la sangre fue llevada a cabo de manera exitosa utilizando una columna ELITE-1, la fase móvil o gas de arrastre es una mezcla de hidrógeno y aire, inyector split y detector de ionización de llama. El método fue validado con los siguientes parámetros: especificidad, linealidad, precisión, exactitud, límite de detección y límite de cuantificación. También se realizó la prueba de aptitud del sistema. El método fue específico para el alcohol, la respuesta fue lineal en el rango de 0,125 ­ 1,0 mg/mL de concentración del analito. El valor del coeficiente de variación o desviación estándar relativa (C.V. o DSR) para la precisión fue óptimo. La recuperación media fue de 99,06%. Y el límite de detección y cuantificación resultaron óptimos para la cuantificación de alcohol en sangre en el rango definido. Finalmente el método cromatográfico fue correlacionado con el método analítico (previamente validado) actualmente utilizado en la División de Dosage Etílico del Instituto de Investigaciones Técnicas de la Universidad Policial Mariscal Antonio José de Sucre, mediante el análisis estadístico de las respuestas analíticas de ambos métodos se obtuvo una muy buena correlación por lo que se concluye que el método cromatográfico puede ser utilizado para los fines consiguientes.

The present study describes the standardization of the method for the quantification of alcohol in blood by Gas Chromatography with Flame Ionization Detector and headspace. The separation of the alcohol from a complex matrix such as blood was successfully carried out using an ELITE-1 column, the mobile phase or entrainment gas is a mixture of hydrogen and air, split injector and flame ionization detector. The method was validated with the following parameters: specificity, linearity, precision, accuracy, limit of detection and limit of quantification. The system fitness test was also performed. The method was alcohol specific, the response was linear in the range of 0.125 - 1.0 mg / mL analyte concentration. The value of the coefficient of variation or relative standard deviation (C.V. or DSR) for precision was optimal. The mean recovery was 99.06%. And the limit of detection and quantification were optimal for the quantification of blood alcohol in the defined range. Finally the chromatographic method was correlated with the enzymatic method (previously validated) currently used in the Ethical Dosage Division of the Institute of Technical Investigations of the Mariscal Antonio José de Sucre Police University, through the statistical analysis of the analytical responses of both methods a very good correlation was obtained by which it is concluded that the chromatographic method can be used for the consequent purposes.
Descritores: Cromatografia
Cromatografia Gasosa
Etanol
-Purificação da Água
CYCLAMATESABDOMINAL INJURIES
Dosagem
Parâmetros de Referência
Gases
Métodos
Tipo de Publ: Estudo de Validação
Responsável: BO138.1 - Biblioteca Central


  6 / 126 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Alves Júnior, Clodomiro
Texto completo
Id: lil-744265
Autor: Coelho, Keylla Dayanne; Alves Junior, Clodomiro; Rocha, Hugo Alexandre de Oliveira; Queiroz Neto, Moacir Francisco de; Vitoriano, Jussier Oliveira; Silva, José Sandro Pereira da.
Título: Influência da composição dos gases durante a modificação da superfície por plasma na adesão de células primárias da polpa dental / Influence of the composition of gases during plasma surface modification on adhesion of primary cells from dental pulp
Fonte: Rev. bras. odontol;71(1):67-71, Jan.-Jun. 2014. ilus, tab.
Idioma: pt.
Resumo: Amostras de titânio foram nitretadas por plasma usando duas composições gasosas: 80%H2-20%N2 e 20%H2-80%N2 e as propriedades físicas químicas desse tratamento foram estudas, bem como sua resposta biológica quando submetidas à cultura de células primárias da polpa dentária. Análise por difração de raios X indicam a formação de TiN nas duas amostras nitretadas ao contrário da superfície não nitretada que continha apenas a fase Ti-α. Verificaram-se modificações na dureza, topografia e molhabilidade dessas amostras quando comparadas às amostras não nitretadas. A adesão celular nessas amostras indica que o tratamento aumenta seu valor sendo superior para amostras tratadas em maior concentração de hidrogênio.

Samples of titanium were nitrided using plasma and a composition of two gases: 80% H2-20% N2 and 20% H2-80% N2. The influence of these treatments on their physical chemical properties and biological response when subjected to the primary cell culture of dental pulp were studied. Analyses by X-ray diffraction indicate the formation of TiN in both nitrided samples in contrast to the non-nitrided surface samples that contained only the Ti-α phase. Changes in hardness, topography and wettability of these samples compared to non-nitrided samples were found as well. Finally, the analysis of cell's adhesion in these samples indicate that treatment increases its value being higher for samples treated at higher hydrogen concentration.
Descritores: Adesão Celular
Cultura Primária de Células
Gases
-Plasma
Titânio
Responsável: BR485.1 - Biblioteca Mário Badan


  7 / 126 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-1012972
Autor: Yu, Wei-Yang; Zhu, Ke-Jun; Li, Qiao-Ping; Lou, Chao; He, Deng-Wei.
Título: Successful medical drainage and surgical treatment for vertebral osteomyelitis and bilateral psoas abscess with gas formation caused by klebsiella pneumoniae in a diabetic patient
Fonte: Rev. Assoc. Med. Bras. (1992);65(5):678-681, May 2019. graf.
Idioma: en.
Projeto: Medical and Health and Technology Project of Zhejiang Province.
Resumo: SUMMARY OBJECTIVE: We describe the case of a diabetic patient who developed vertebral osteomyelitis and bilateral psoas abscess with gas formation due to klebsiella pneumoniae. METHODS: A 64-year-old woman with a 4-year history of type-2 diabetes mellitus was admitted to the Emergency Department. The subject had a 2-day history of high-grade fever associated with chills and a 5-hour history of consciousness. She received empirical treatment with febrifuge, after which her fever decreased. RESULTS: Her fever recurred after an interval of three hours. A computed tomography scan of the abdomen revealed vertebral osteomyelitis and bilateral psoas muscle abscess with gas formation. Blood culture and purulent fluid described the growth of the Klebsiella pneumoniae. The patient received antibiotic therapy and bilateral drainage therapy after the drainage catheter was placed into the abscess cavity by CT-guidance. Due to the serious damage to the vertebral column and permanent pain, the patient underwent minimally invasive internal spinal fixation and recovered successfully. CONCLUSION: A case of vertebral osteomyelitis and bilateral psoas abscess with gas formation caused by Klebsiella pneumoniae in a diabetic patient. Antibiotic therapy, drainage, and minimally invasive internal spinal fixation were performed, which enabled a good outcome.

RESUMO OBJETIVO: Descrever o caso de uma paciente diabética que desenvolveu osteomielite vertebral e abcesso bilateral do psoas com formação de gás causada por klebsiella pneumoniae. MÉTODOS: Uma mulher de 64 anos de idade, com 4 anos de histórico de diabetes mellitus tipo 2, foi admitida no Serviço de Emergência. A paciente apresentava um quadro de dias de febre alta acompanhada de calafrios e um histórico de 5 horas de consciência. Ela recebeu tratamento empírico com antitérmico, após o qual a febre diminuiu. RESULTADOS: A febre retornou após um intervalo de três horas. Uma tomografia computadorizada do abdome revelou osteomielite vertebral e abcesso bilateral do músculo psoas com formação de gás. A cultura do sangue e o fluido purulento revelaram o crescimento de Klebsiella pneumoniae. A paciente recebeu antibióticos e terapia de drenagem bilateral após o cateter de drenagem ser posicionado na cavidade do abscesso com auxílio de TC. Devido a sérios danos à coluna vertebral e a dor permanente, a paciente foi submetida à fixação vertebral interna minimamente invasiva e recuperou-se com sucesso. CONCLUSÃO: Um caso de osteomielite vertebral e abscesso do psoas bilateral com a formação de gás causada por Klebsiella pneumoniae em uma paciente diabética. Antibioticoterapia, drenagem e fixação vertebral interna minimamente invasiva foram realizadas, o que permitiu um bom resultado.
Descritores: Osteomielite/cirurgia
Doenças da Coluna Vertebral/cirurgia
Infecções por Klebsiella/cirurgia
Abscesso do Psoas/cirurgia
Complicações do Diabetes/cirurgia
Klebsiella pneumoniae/patogenicidade
-Osteomielite/microbiologia
Doenças da Coluna Vertebral/microbiologia
Infecções por Klebsiella/microbiologia
Tomografia Computadorizada por Raios X/métodos
Drenagem/métodos
Reprodutibilidade dos Testes
Resultado do Tratamento
Abscesso do Psoas/microbiologia
Complicações do Diabetes/microbiologia
Gases/metabolismo
Pessoa de Meia-Idade
Limites: Humanos
Feminino
Tipo de Publ: Relatos de Casos
Responsável: BR1.1 - BIREME


  8 / 126 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Chile
Texto completo
Id: biblio-991347
Autor: Balkenhol, Marco; Castillo, Alejandro; Soto, Michael; Feijoo, Matías; Merino, Waldo.
Título: Huella de carbono en el Hospital Base de Puerto Montt / Measurement of the carbon footprint at a regional hospital
Fonte: Rev. méd. Chile;146(12):1384-1389, dic. 2018. tab, graf.
Idioma: es.
Resumo: Background: Measuring the carbon footprint (CF) makes it possible to estimate the contribution of clinical activity to global warming. Aim: To measure the emitter components of CO2 equivalents (CO2e) at the Hospital Base, Puerto Montt (HBPM). Material and methods: Descriptive study with data collected retrospectively between January and December 2016 from the HBPM database. The data analyzes direct and indirect emissions as well as other indirect emissions beyond the organizational limits. Results: Of the 9,660.3 tons of CO2e emitted by the HBPM in 2016, 46% were derived from consumption of electricity, 29% derived from the generation of residues, and 10% from clinical gas consumption, of which Sevoflurane was the greatest contributor. Conclusions: Clinical gases are a significant source of CO2e emissions. Sevoflurane alone is in fourth place in CO2e emissions at the HBPM. Estimating the CF produced by HBPM is the first step in the discussion of measures to reduce the environmental impact of our activity.
Descritores: Efeito Estufa/estatística & dados numéricos
Pegada de Carbono/estatística & dados numéricos
Gases/química
Hospitais/estatística & dados numéricos
-Chile
Monitoramento Ambiental/métodos
Estudos Retrospectivos
Limites: Humanos
Responsável: CL1.1 - Biblioteca Central


  9 / 126 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Chile
Texto completo
Id: biblio-890090
Autor: Silva, Adrián; Barrandeguy, Margarita; Quintana, Javier.
Título: Modelación de riesgos hacia los trabajadores y comunidad por emisiones de gas licuado de petróleo, utilizando software Slab View en la ciudad de Los Ángeles, Chile / Risks modeling to workers and the community for releases of petroleum liquid gas, using software slab view in los angeles city, Chile
Fonte: Cienc. Trab;19(60):183-187, dic. 2017. tab, graf.
Idioma: es.
Projeto: Vicerrectoría de Investigación y Desarrollo. Universidad de Concepción.
Resumo: RESUMEN: 21. Con el software SLAB VIEW se realizaron modelaciones para determi nar cuantitativamente los riesgos hacia los trabajadores y comunidad por emisiones accidentales de gas licuado de petróleo, desde fuentes de uso y almacenamiento, dentro del radio urbano de Los Ángeles (Chile). Se modelaron 23 fuentes con categoría de riesgo grave, clase "C" y las 3 fuentes con categoría muy grave, clase "D", identificadas con la meto dología APELL, aplicada en el estudio de Silva et. al (2016). 22. 23. Se evaluó el comportamiento espacial y temporal de las fugas de gas para estanques identificados con capacidades de 2 m3, 4 m3, 11 m3 y 49 m3 utilizando promedios estacionales de variables meteorológicas consideradas en un periodo de evaluación de cinco años. Se utiliza ron variables de tiempo de fuga evaluando su comportamiento en 1, 3 y 5 minutos, con el fin de identificar las condiciones del peor escenario. Como resultado se obtiene que el comportamiento de la nube depende de la estabilidad atmosférica, siendo la condición esta ble donde concentraciones de interés permanecen por más tiempo alcanzando mayores distancias y que el peor escenario para una fuga son las bajas temperaturas y las condiciones atmosféricas estables. Como conclusión, puede establecerse que en la zona de estudio exis ten estanques que son potencialmente peligrosos por deflagración para trabajadores y la comunidad; sin embargo, los tiempos de expo sición no generan peligros por exposición aguda.

ABSTRACT: 28. With the SLAB VIEW software, modeling wasperformed to determine quantitatively the risks to workers and the community from acciden tal releases of liquefied petroleum gas, from sources use and storage, within the urban radius of Los Angeles (Chile). 23 sources with a severe risk category class "C" and the 3 very severe risk category class "D" identified with the APELL methodology, applied in the study by Silva et al. (2016), were modeled. 29. 30. The spatial and temporal behavior of the gas leaking for tanks iden tified with capacities of 2m3, 4m3, 11m3 and 49m3 were evaluated using seasonal averages of meteorological variables considered in a five - year evaluation period. Leakage time variables were used evaluating their behavior in 1, 3 and 5 minutes in order to identify worst-case conditions. As a result it is obtained that the behavior of the cloud depends on the atmospheric stability, being the stable condition where concentrations of interest remain longer reaching greater distances and that the worst scenario for a leak is the low temperatures and the stable atmospheric conditions. As a conclusion, it can be established that in the study area, there are ponds that are potentially dangerous due to deflagration for workers and the com munity, however, exposure times do not generate hazards due to acute exposure.
Descritores: Gestão de Riscos
Software
Riscos Ocupacionais
Vazamento de Gases/prevenção & controle
Gases/efeitos adversos
-Estações do Ano
Temperatura
Vento
Petróleo
Chile
Exposição Ocupacional/prevenção & controle
Medição de Risco
Área Urbana
Estabilidade Atmosférica
Gases/análise
Umidade
Limites: Humanos
Responsável: CL1.1 - Biblioteca Central


  10 / 126 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo
Texto completo
Id: biblio-1147328
Autor: Morais, Leonardo Fiusa de; Almeida, João Carlos de Carvalho; Nepomuceno, Delci de Deus; Freitas, Rafaela Scalise Xavier de; Melo, Bárbara Maria Gomes de; Silva, Joice Fátima Moreira.
Título: Nutritive value of elephant grass hay ammoniated by urea / Valor nutritivo do feno de capim elefante amonizado por uréia
Fonte: Biosci. j. (Online);36(5):1498-1506, 01-09-2020. tab.
Idioma: en.
Resumo: The aim of this study was to evaluate the effect of ammoniation by urea on the nutritional value of elephant grass hay harvested after flowering. A completely randomized design, in double factorial designs with an additional treatment: 4 urea doses (2, 4, 6 and 8%) x 2 treatment periods (30 and 45 days) + 1 (Control) with four replicates each, was employed. Dry matter, ash, ether extract, neutral detergent fiber, acid detergent fiber, cellulose, lignin, neutral detergent fiber corrected for the ash and the protein, total nitrogen, acid detergent insoluble nitrogen, neutral detergent insoluble nitrogen, non-protein nitrogen, in vitro gas production and carbohydrates fractionation were analyzed. The treatments influenced the contents of DM, EE, NDF, ADF, lignin, cellulose, NDFap, fraction A + B1, fraction B2, fraction C, TN, NPN, ADIN, NDIN, L and Vf2. There was a positive linear effect of urea dose for NDF, ADIN, NDIN and L, positive linear effect on fraction A + B1, NT and NPN, and positive quadratic effect for Vf2, with absolute maximum point of 4.5%. Elephant grass hay harvested after flowering has its nutritional value improved, with a minimum dose of 4.5% urea on a dry matter basis.(AU)

Objetivou-se avaliar o efeito da amonização com ureia sobre o valor nutritivo do feno de capim elefante colheitado após florescimento. O estudo foi delineado, em esquema fatorial duplo com um tratamento adicional: 4 doses de ureia (2, 4, 6 e 8%) x 2 período de tratamento (30 e 45 dias) + 1 tratamento controle, com 4 repetições cada. As variáveis analisadas foram: matéria seca (MS), cinzas, extrato etéreo (EE), fibra em detergente neutro (FDN) e ácido (FDA), FDN corrigida para cinzas e proteínas (FDNcp), celulose, lignina, nitrogênio total (NT), nitrogênio insolúvel em detergente ácido (NIDA) e neutro (NIDN), nitrogênio não proteico (NNP). Produção de gases in vitro proveniente dos carboidratos não fibrosos (Vf1) e fibrosos (Vf2), taxa de fermentação dos carboidratos não fibrosos (k1) e fibrosos (k2) e tempo de colonização bacteriana do substrato (L), além do fracionamento de carboidratos. Os tratamentos influenciaram os teores de MS, EE, FDN, FDA, lignina, celulose, FDNcp, fração A + B1, fração B2, fração C dos carboidratos, NT, NNP, NIDA, NIDN, L e Vf2. Houve efeito linear decrescente de dose de ureia para FDNcp, NIDA, NIDN e L, crescente para fração A+B1, NT e NNP, e, quadrático crescente de dose de ureia para Vf2, com ponto máximo absoluto de 4,5% de ureia obtido após derivar a equação de regressão aos 45 dias de tratamento do feno. Concluindo que feno de capim elefante colheitado após florescimento tem seu valor nutricional melhorado, com dose mínima de 4,5% de ureia em base da matéria seca.(AU)
Descritores: Ureia
Pennisetum
Valor Nutritivo
-Técnicas In Vitro
Carboidratos
Gases
Nitrogênio
Responsável: BR396.1 - Biblioteca Central



página 1 de 13 ir para página                         
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde