Base de dados : LILACS
Pesquisa : D01.490.100.375 [Categoria DeCS]
Referências encontradas : 4 [refinar]
Mostrando: 1 .. 4   no formato [Detalhado]

página 1 de 1

  1 / 4 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-1097204
Autor: Bendek Del Prete, Georgina.
Título: Riesgo comparativo de reacción anafiláctica asociada a hierro endovenoso / Comparative risk of anaphilactic reactions associated with intravenous iron products
Fonte: Evid. actual. práct. ambul;20(4):98-98, 2017. tab..
Idioma: es.
Descritores: Compostos Férricos/efeitos adversos
Sais de Ferro/efeitos adversos
Óxido Ferroso-Férrico/efeitos adversos
Ácido Glucárico/efeitos adversos
Gluconatos/efeitos adversos
Anafilaxia/etiologia
Complexo Ferro-Dextran/efeitos adversos
-Estados Unidos/epidemiologia
Compostos Férricos/administração & dosagem
Risco
Óxido Ferroso-Férrico/administração & dosagem
Óxido de Ferro Sacarado
Ácido Glucárico/administração & dosagem
Gluconatos/administração & dosagem
Anafilaxia/epidemiologia
Injeções Intravenosas
Complexo Ferro-Dextran/administração & dosagem
Limites: Humanos
Masculino
Feminino
Idoso
Tipo de Publ: Comentário
Responsável: AR2.1 - Biblioteca Central


  2 / 4 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-1010412
Autor: Mohamed, Saleh A; Al-Harbi, Majed H; Almulaiky, Yaaser Q; Ibrahim, Ibrahim H; El-Shishtawy, Reda M.
Título: Immobilization of horseradish peroxidase on Fe3O4 magnetic nanoparticles
Fonte: Electron. j. biotechnol;27:84-90, May. 2017. graf, ilus, tab.
Idioma: en.
Resumo: Background: Iron magnetic nanoparticles have attracted much attention. They have been used in enzyme immobilization because of their properties such as product is easily separated from the medium by magnetic separation. The present work was designed to immobilize horseradish peroxidase on Fe3O4 magnetic nanopraticles without modification. Results: In the present study, horseradish peroxidase (HRP) was immobilized on non-modified Fe3O4 magnetic nanoparticles. The immobilized HRP was characterized by FT-IR spectroscopy, scanning electron microscopy, and energy dispersive X-ray. In addition, it retained 55% of its initial activity after 10 reuses. The optimal pH shifted from 7.0 for soluble HRP to 7.5 for the immobilized HRP, and the optimal temperature shifted from 40°C to 50°C. The immobilized HRP is more thermostable than soluble HRP. Various substrates were oxidized by the immobilized HRP with higher efficiencies than by soluble HRP. Km values of the soluble and immobilized HRP were 31 and 45 mM for guaiacol and 5.0 and 7.0 mM for H2O2, respectively. The effect of metals on soluble and immobilized HRP was studied. Moreover, the immobilized HRP was more stable against high concentrations of urea, Triton X-100, and isopropanol. Conclusions: Physical immobilization of HRP on iron magnetic nanoparticles improved the stability toward the denaturation induced by pH, heat, metal ions, urea, detergent, and water-miscible organic solvent.
Descritores: Enzimas Imobilizadas/química
Óxido Ferroso-Férrico/química
Peroxidase do Rábano Silvestre/química
-Solubilidade
Espectrometria por Raios X
Temperatura
Microscopia Eletrônica de Varredura
Espectroscopia de Infravermelho com Transformada de Fourier
Enzimas Imobilizadas/metabolismo
Nanopartículas/química
Peroxidase do Rábano Silvestre/metabolismo
Concentração de Íons de Hidrogênio
Responsável: CL1.1 - Biblioteca Central


  3 / 4 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-755070
Autor: Fiorante, Pedro de Freitas; Fiorante, Pedro de Freitas; Palma, Mauri Sergio Alves.
Título: Development and validation of analytical methodology with focus on the qualification of powder mixers / Misturadores de pós/validação analítica; Espectrofotometria; Óxido férrico/quantificação; Lactose monoidratada/análise quantitativa
Fonte: Braz. j. pharm. sci;51(2):273-284, Apr.-June 2015. tab, ilus.
Idioma: en.
Resumo:

This study aims at developing an analytical procedure capable of quantifying the ferric oxide present in the mixture of ferric oxide/lactose monohydrate (0.4% w/w). The analytical procedure was checked for specificity, linearity, precision (system repeatability, procedure repeatability and intermediate precision), accuracy, stability of solutions and robustness of the procedure. The concentration of Fe (III) was determined by spectrophotometry at 480 nm based on calibration curves. The specificity was verified. The linearity was obtained in the range of 11.2 to 16.8 µg of ferric oxide/mL. The relative standard deviation (RSD) of the system repeatability, procedure repeatability and intermediate precision, were not more than 2%. The RSD of the accuracy values were less than 0.75%. The stability of the samples was checked over a 24 hours assay. In the robustness evaluation, the wavelength and the concentration of hydrochloric acid varied. The maximum absorbance deviation due to wavelength variation was 0.14 percent, and the maximum deviation due to the hydrochloric acid concentration variation was 2.4%, indicating that the concentration of hydrochloric acid is critical to the analysis of ferric oxide. The procedure developed was validated and is suitable to the performance qualification of powder mixers..

O objetivo deste trabalho foi desenvolver um método analítico capaz de quantificar o óxido férrico presente na mistura óxido férrico/lactose monoidratada (0,4% w/w). Verificou-se a especificidade, linearidade, precisão (repetibilidade do sistema, repetibilidade do método e precisão intermediária), exatidão, estabilidade das soluções e robustez. A concentração de Fe(III) foi determinada por espectrofotometria em 480 nm com base em curvas de calibração. Verificou-se a especificidade verificada. A linearidade foi obtida na faixa de 11,2 a 16,8 µg de óxido férrico/mL. O desvio padrão relativo (DPR) da repetibilidade do sistema, método e precisão intermediária foram inferiores a 2%. Os valores de DPR da exatidão foram inferiores a 0,75%. A estabilidade das amostras foi verificada ao longo de 24 horas de ensaio. Na avaliação da robustez variou-se o comprimento de onda e a concentração de ácido clorídrico. O desvio máximo de absorbância ao se variar o comprimento de onda foi de 0,14%, enquanto que para a concentração de ácido clorídrico o desvio foi de 2,4% para a concentração de 0,8 M. Assim, a concentração de ácido clorídrico é crítica para a análise de óxido férrico. O método desenvolvido foi validado e é adequado à qualificação do desempenho de misturadores de pós e granulados...

Descritores: Poeira
Misturadores de Massa/métodos
Óxido Ferroso-Férrico/análise
-Fenômenos Químicos/métodos
Controle de Qualidade
Limites: Humanos
Responsável: BR40.1 - DBD - Divisão de Biblioteca e Documentacão do Conjunto das Químicas


  4 / 4 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Chile
Texto completo
Id: lil-448768
Autor: Whitehead, Neil Evan; Tani, Atushi; Kazue, Tazaki; Motoji, Ikeya.
Título: Preliminary results of using ESR to examine biofilms
Fonte: Electron. j. biotechnol;7(3):11-12, Dec. 2004. ilus, tab, graf.
Idioma: en.
Resumo: This preliminary work shows ESR (Electron Spin Resonance) can be used to detect biofilms, particularly from Fe-metabolising bacteria. A film was detected by ESR as early as 1 day, hence possibly more sensitively than by fluorescent methods. Films can probably be detected as early as one hour. Spectra contain a very broad peak at g=2.13, probably due to ferrihydrite. Results of field experiments from streams and ponds in New Zealand and Japan, particularly the Minoh River, showed a general increase of ferrihydrite with time. Loss by exfoliation was later than 20 days. The rate of accumulation was faster in a nutrient-rich stagnant pond. Hematite (g=4.3) was often observed, magnetite (g=9) once, and usually small amounts of a common bacterial decay product. The latter was detected for at least 18 months film storage. ESR is a particularly good tool for observing the growth of oxic biofilms containing Fe-metabolising bacteria, and should be just as sensitive for observing Mn-metabolising bacteria in reducing conditions.
Descritores: Bactérias
Biofilmes
Espectroscopia de Ressonância de Spin Eletrônica/métodos
Compostos Férricos
Óxido Ferroso-Férrico
Responsável: CL1.1 - Biblioteca Central



página 1 de 1
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde