Base de dados : LILACS
Pesquisa : D02.092.782.258.368 [Categoria DeCS]
Referências encontradas : 5 [refinar]
Mostrando: 1 .. 5   no formato [Detalhado]

página 1 de 1

  1 / 5 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Uruguai
Texto completo
Id: biblio-1024952
Autor: Martinelli, Sylvia; Alburquerque, Gimena; Silva, Lorena.
Título: Efecto del EDTAC y del ácido cítrico sobre la pared dentinaria. Variación del tiempo de exposición y la edad dentaria / Effect of EDTAC and citric acid on dentinal walls. Variation of exposure time and dental age
Fonte: Odontoestomatol;21(34):5-15, Jul-Dic. 2019.
Idioma: es.
Resumo: The aim of this study was to find a formula and application time for chelators effective in cleaning the root canal without causing erosion and considering dental age. The sample included 120 teeth: 60 taken from young patients and 60 from adult patients. They were instrumented and irrigated with 2.5% sodium hypochlorite (NaOCl). Each subgroup was divided randomly into six groups: 4 groups of 12 teeth and 2 control groups of 6 teeth. In the final irrigation, 17% ethylenediaminetetraacetic acid plus Cetavlón (EDTAC) or 10% citric acid was applied for 1 or 3 minutes according to each group. The results showed a high level of cleanliness, and a few showed erosion of the dentinal tubules. Satisfactory results were obtained in the removal of the smear layer when applying EDTAC or citric acid combined with NaOCl. Erosion was present in different degrees regardless of dental age, but it was indeed affected by the irrigant exposure time.

O objetivo deste estudo foi obter uma fórmula e um tempo de aplicação dos quelantes efetivos que permitam a limpeza das paredes do canal sem causar erosões, levando em consideração a idade dental. A amostra foi composta por 120 dentes, 60 de pacientes jovens e 60 de pacientes adultos, foram instrumentados e irrigados com hipoclorito de sódio (NaOCl) a 2,5%. Cada subgrupo foi dividido aleatoriamente em 6 grupos: 4 grupos de 12 dentes e 2 grupos de controle com 6 dentes cada um. Na irrigação final, ácido etilenodiaminotetracético com Cetavlón (EDTAC) 17% ou ácido cítrico 10% foi aplicado por 1 ou 3 minutos, dependendo do grupo. Os resultados mostraram um bom nível de limpeza com algumas amostras com erosão dos túbulos dentinários. Com EDTAC ou ácido cítrico combinado com NaOCl, resultados satisfatórios foram obtidos na remoção da camada de esfregaço . A erosão esteve presente em seus diferentes graus independentemente da idade dentária, mas não do tempo de exposição do irrigante.
Descritores: Erosão Dentária
Ácido Edético
Etilenodiaminas
-Quelantes
Camada de Esfregaço
Limites: Humanos
Tipo de Publ: Research Support, Non-U.S. Gov't
Responsável: UY20.1 - Departamento de Documentación y Biblioteca


  2 / 5 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-732248
Autor: Santana, Márcia Luciana Carregosa; Sousa Júnior, José Aginaldo de; Leal, Pollyana Caldeira; Faria-e-Silva, André Luis.
Título: Does Maintaining a Bottle of Adhesive Without the Lid Significantly Reduce the Solvent Content?
Fonte: Braz. dent. j;25(6):543-545, Nov-Dec/2014. tab, graf.
Idioma: en.
Resumo: This study aimed to evaluate the effect of maintaining a bottle of adhesive without its lid on the solvent loss of the etch-and-rinse adhesive systems. Three 2-step etch-and-rinse adhesives with different solvents (acetone, ethanol or butanol) were used in this study. Drops of each adhesive were placed on an analytical balance and the adhesive mass was recorded until equilibrium was achieved (no significant mass alteration within time). The solvent content of each adhesive and evaporation rate of solvents were measured (n=3). Two bottles of each adhesive were weighted. The bottles were maintained without their lids for 8 h in a stove at 37 ºC, after which the mass loss was measured. Based on mass alteration of drops, acetone-based adhesive showed the highest solvent content (46.5%, CI 95%: 35.8-54.7) and evaporation rate (1.11 %/s, CI95%: 0.63-1.60), whereas ethanol-based adhesive had the lowest values (10.1%, CI95%: 4.3-16.0; 0.03 %/s CI95%: 0.01-0.05). However, none of the adhesives bottles exhibited significant mass loss after sitting for 8 h without their lids (% from initial content; acetone - 96.5, CI 95%: 91.8-101.5; ethanol - 99.4, CI 95%: 98.4-100.4; and butanol - 99.3, CI 95%: 98.1-100.5). In conclusion, maintaining the adhesive bottle without lid did not induce significant solvent loss, irrespective the concentration and evaporation rate of solvent.

Este estudo avaliou o efeito da manutenção do frasco do adesivo sem sua tampa na perda de solvente de sistemas adesivos convencionais. Três adesivos convencionais de 2 passos com diferentes solventes (acetona, etanol ou butanol) foram usados neste estudo. Gotas de cada adesivo foram colocadas em uma balança analítica e a massa dos adesivos foi registrada até a obtenção do equilíbrio (nenhuma alteração significativa com o tempo). O conteúdo de solvente de cada adesivo e a taxa de evaporação dos solventes foram mensurados (n=3). Dois frascos de cada adesivo foram pesados. Os frascos foram mantidos sem suas tampas por 8 h em uma estufa a 37 ºC, seguido pela mensuração da pera de massa. Baseado na alteração de massa das gotas, o adesivo a base de acetona demonstrou o maior conteúdo de solvente (46,5%, IC 95%: 35,8-54,7) e de taxa de evaporação (1,11 %/s, IC95%: 0,63-1,60), enquanto que o adesivo à base de etanol teve os menores valores (10,1%, IC95%: 4,3-16,0; 0,03 %/s IC95%: 0,01-0,05). Entretanto, nenhum dos frascos dos adesivos exibiu perda significante de massa após ficar por 8 h sem suas tampas (% do conteúdo inicial; acetona - 96,5, IC95%: 91,8-101,5; etanol - 99,4, IC95%: 98,4-100,4; e butanol - 99,3, IC95%: 98,1-100,5). Em conclusão, a manutenção do frasco do adesivo sem tampa não induziu perda significante de solvente independente da concentração e da taxa de evaporação do solvente.
Descritores: Aminofilina/uso terapêutico
Anafilaxia/induzido quimicamente
Asma/induzido quimicamente
Sulfitos/imunologia
Urticária/induzido quimicamente
-Administração Tópica
Aminofilina/imunologia
Asma/complicações
Rotulagem de Medicamentos
Hipersensibilidade a Drogas/imunologia
Emolientes/administração & dosagem
Epinefrina/uso terapêutico
Etilenodiaminas/imunologia
Dermatoses da Mão/tratamento farmacológico
Testes do Emplastro
Sulfitos/administração & dosagem
Limites: Adulto
Feminino
Humanos
Tipo de Publ: Relatos de Casos
Responsável: BR1.1 - BIREME


  3 / 5 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Rodrigues, Alfredo José
Texto completo
Id: lil-540498
Autor: Reis, Graziela Saraiva; Augusto, Viviane dos Santos; Souza, Maria Eliza Jordani de; Baldo, Caroline Floreoto; Rodrigues, Alfredo José; Evora, Paulo Roberto Barbosa.
Título: Exhaled breath condensate collection for nitrite dosage: a safe and low cost adaptation / Coleta do condensado do ar exalado pulmonar para a dosagem de nitrito: Uma adaptação segura e barata
Fonte: Acta cir. bras;25(2):206-213, Mar.-Apr. 2010. graf, tab.
Idioma: en.
Resumo: Purpose: Standardization of a simple and low cost technique of exhaled breath condensate (EBC) collection to measure nitrite. Methods: Two devices were mounted in polystyrene boxes filled either with crushed ice/salt crystals or dry ice/crushed ice. Blood samples were stored at -70º C for posterior nitrite dosages by chemiluminescence and the Griess reaction. Results: a) The use of crushed ice/dry ice or salt revealed sufficient EBC room air collection, but was not efficient for patients under ventilation support; b) the method using crushed ice/salt collected greater EBC volumes, but the nitrite concentrations were not proportional to the volume collected; c) The EBC nitrite values were higher in the surgical group using both methods; d) In the surgical group the nasal clip use diminished the EBC nitrite concentrations in both methods. Conclusions: The exhaled breath condensate (EBC) methodology collection was efficient on room air breathing. Either cooling methods provided successful EBC collections showing that it is possible to diminish costs, and, amongst the two used methods, the one using crushed ice/salt crystals revealed better efficiency compared to the dry ice method.

Objetivo: Padronizar técnica simples e barata de coleta do condensado do ar exalado pulmonar (CEP) para medir nitrito. Métodos: Dois dispositivos foram montados em caixas de isopor e preenchidos com gelo picado/sal grosso ou gelo picado/gelo seco. Amostras de sangue foram armazenadas a -70º C para dosagem de nitrito por quimiluminescência e pela reação de Griess. Resultados: a) a utilização de gelo picado/gelo seco ou sal foi eficiente para a coleta em respiração espontânea, mas ineficiente durante ventilação mecânica; b) o método gelo picado/sal coletou volumes maiores, sem aumento proporcional do nitrito; c) os valores do nitrito foram mais elevados no grupo cirúrgico utilizando os dois métodos; d) no grupo cirúrgico com clipe nasal ocorreu diminuição do nitrito em ambos os métodos. Conclusões: A metodologia do condensado do ar exalado pulmonar (CEP) foi eficiente na coleta respirando em ar ambiente. Os dois métodos de congelamento foram eficientes mostrando que é possível diminuir os custos, e, entre os dois métodos utilizados, o uso de gelo picado/sal mostrou melhor eficiência quanto ao volume da coleta do CEP em comparação com o uso de gelo seco.
Descritores: Testes Respiratórios/métodos
Nitritos/análise
-Biomarcadores/análise
Testes Respiratórios/instrumentação
Estudos de Casos e Controles
Custos e Análise de Custo
Etilenodiaminas
Luminescência
Sulfanilamidas
Limites: Adulto
Idoso
Feminino
Humanos
Masculino
Pessoa de Meia-Idade
Adulto Jovem
Tipo de Publ: Research Support, Non-U.S. Gov't
Estudo de Validação
Responsável: BR1.1 - BIREME


  4 / 5 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Chile
Texto completo
Id: lil-437384
Autor: Matias, Carlos M; Matos, Nuno C; Arif, Mona; Dionisio, Jose C; Quinta-Ferreira, M Emilia.
Título: Effect of the zinc chelator N, N, N',N'- tetrakis (2-pyridylmethyl)ethylenediamine (TPEN) on hippocampal mossy fiber calcium signals and on synaptic transmission
Fonte: Biol. Res;39(3):521-530, 2006. ilus.
Idioma: en.
Projeto: Pluriannual of CNC.
Resumo: An important pool of chelatable zinc is present in the synaptic vesicles of mossy fiber terminals from hippocampal CA3 area, being zinc released following single or repetitive electrical stimulation. Previous studies have suggested different synaptic roles for released mossy fiber zinc, including the inhibition of presynaptic calcium and of postsynaptic N-methyl-D-aspartate (NMDA) and gamma amino-butiric acid (GABA A) receptors. The effect of endogenously released zinc on mossy fiber long-term potentiation (LTP) induction also is not yet established. We have investigated the effect of the permeant zinc chelator N,N,N',N'-tetrakis(2-pyridylmethyl) ethylenediamine (TPEN) on mossy fiber calcium and on synaptic transmission, before and during the application of LTP-inducing stimulation. We have found, using the calcium indicator Fura-2, that single and tetanically-evoked mossy fiber calcium signals are both enhanced in the presence of 20 ìM TPEN, while the single field potentials are unaffected. As expected, no effect was observed on the single calcium signals or field potentials obtained at the CA3-CA1 synapses, from the CA1 area, which has a lower concentration of vesicular zinc. These results support the idea that at the hippocampal mossy fiber synapses, released zinc inhibits presynaptic calcium mechanisms. A higher concentration of TPEN (100 ìM) significantly reduced mossy fiber synaptic transmission but did not prevent the induction of mossy fiber LTP, suggesting that zinc is not required for the formation of this form of LTP.
Descritores: Sinalização do Cálcio/efeitos dos fármacos
Quelantes/farmacologia
Etilenodiaminas/farmacologia
Fibras Musgosas Hipocampais/efeitos dos fármacos
Transmissão Sináptica/efeitos dos fármacos
-Sinalização do Cálcio/fisiologia
Estimulação Elétrica
Potenciação de Longa Duração
Ratos Wistar
Transmissão Sináptica/fisiologia
Limites: Animais
Ratos
Tipo de Publ: Research Support, Non-U.S. Gov't
Responsável: BR1.1 - BIREME


  5 / 5 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Cunha, F. Q
Texto completo
Id: lil-425785
Autor: Siebra, M. X; Santos, M. A; Almeida, T. L. P; Leite, A. C. R. M; Cunha, F. Q; Rocha, F. A. C.
Título: Evidence for the participation of nitric oxide in pemphigus
Fonte: Braz. j. med. biol. res = Rev. bras. pesqui. méd. biol;39(5):671-675, May 2006. ilus, graf.
Idioma: en.
Projeto: CAPES.
Resumo: Pemphigus is an inflammatory autoimmune disorder of the skin. Nitric oxide (NO) is an inflammatory mediator linked to a variety of physiological and pathophysiological phenomena that include skin tumors, psoriasis, urticaria, and atopic dermatitis. Inflammatory cells present in pemphigus lesions are important sources of NO production. We investigated whether NO is involved in pemphigus. A prospective cohort study was conducted at the Dermatology Service of the Hospital Universitário Walter Cantídio of the Federal University of Ceará. All patients seen at the outpatient clinic between August 2000 and July 2001, with a clinically and histologically confirmed diagnosis of pemphigus were included. The median age was 42.5 years (range: 12-69 years) with a male to female ratio of 3:2. Total serum nitrite levels, used as a marker for NO production, were determined by the Griess reaction. Skin biopsies from pemphigus and breast surgery (control) patients were used for the detection of the inducible NO synthase (iNOS) by immunohistochemistry. Twenty-two (22) patients with pemphigus and eight (8) controls who did not differ in demographic characteristics were included. Total serum nitrite levels were significantly higher (>7 æmol/L) in pemphigus patients compared to controls (<6 æmol/L), regardless of the severity of the clinical activity of pemphigus (P < 0.0001). All pemphigus biopsies presented increased immunostaining for iNOS that was not detected in normal skin samples. These data are the first to demonstrate that pemphigus patients display increased serum NO levels that are associated with increased iNOS expression in the affected skin.
Descritores: Óxido Nítrico Sintase Tipo II/metabolismo
Óxido Nítrico/metabolismo
Pênfigo/enzimologia
-Biomarcadores/sangue
Estudos de Casos e Controles
Estudos de Coortes
Etilenodiaminas
Imuno-Histoquímica
Nitratos/sangue
Nitritos/sangue
Estudos Prospectivos
Pênfigo/etiologia
Índice de Gravidade de Doença
Sulfanilamidas
Limites: Adolescente
Adulto
Idoso
Criança
Feminino
Humanos
Masculino
Pessoa de Meia-Idade
Responsável: BR1.1 - BIREME



página 1 de 1
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde