Base de dados : LILACS
Pesquisa : D02.241.081.069 [Categoria DeCS]
Referências encontradas : 15 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 2 ir para página        

  1 / 15 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Chile
Texto completo
Id: biblio-893115
Autor: Saraydin, Serpil Ünver; Saraydin, Dursun; Sahin Inan, Zeynep Deniz; Özdenoglu Kutlu, Berna.
Título: The effects of monomers used in polymeric biomaterials on renal tissue / Efectos de los monómeros de los biomateriales poliméricos utilizados en tejido renal
Fonte: Int. j. morphol;35(4):1203-1208, Dec. 2017. graf.
Idioma: en.
Resumo: SUMMARY: Biomaterials are mostly polymers and are used in artificial organ production in contemporary medicine. They are prepared by the polymerization reaction of many monomers. There are many monomers used in biomaterial production. In this study, we investigated whether acrylamide (AAm), methacrylamide (MAAm), N-isopropylacrylamide (NIPAm) and acrylic acid (AAc) used in polymeric biomaterial production had histopathological effects on renal tissue. In the present study, Wistar albino rats weighing ~ 250-300 g were used. Following the intramuscular injections of 1 mL aqueous monomer solutions at 50 mg/kg concentrations, acrylamide group animals were sacrificed at 1st, 2nd and 3rd weeks, the other monomer group animals were sacrificed at 1st, 2nd, 4th and 6th weeks. One mL serum physiologic were injected intramuscularly to the control group animals at the same time intervals with the experimental group animals. After histological follow-up, serial sections were prepared for evaluation under light microscope. In addition, the diameters of glomeruli and glomeruli space (Bowman's space) are measured, and the changes of the values of all groups with the exposure time were investigated. Acrylamide and its derivatives cause glomerular, arteriolar and tubule interstitial damage in the renal tissue. The narrowing glomeruli space, increasing diffuse mesangial matrix and tubular dilation was observed in some groups. In addition, dilatation, dissociation of tubular epithelium, thickening basement membranes and glycogenic vacuolization was also noted. These adverse results may be due to residual monomer. There should be no monomer residue in the polymer used as biomaterials.

RESUMEN: Los biomateriales en su mayoría son polímeros utilizados en la producción de órganos artificiales en la medicina contemporánea. Éstos son preparados mediante la reacción de polimerización de varios monómeros. Existe una gran cantidad de monómeros usados en la producción de biomateriales. En este estudio se investigó si la acrilamida (AAm), la metacrilamida (MAAm), la N-isopropilacrilamida (NIPAm) y el ácido acrílico (AAc) utilizados en la producción de biomateriales poliméricos tuvieron efectos histopatológicos en el tejido renal. En el presente estudio, se utilizaron ratas Wistar albinas que pesaban 250-300 g. Después de las inyecciones intramusculares (1 ml) de soluciones acuosas de monómero a concentraciones de 50 mg / kg, los animales del grupo de la acrilamida se sacrificaron a la 1ª, 2ª y 3ª semanas, los otros animales del grupo monómero se sacrificaron a las 1ª, 2ª, 4ª y 6ª semanas. Se inyectaron intramuscularmente 1 ml de suero fisiológico a los animales del grupo control en los mismos intervalos de tiempo que los animales del grupo experimental. Después del análisis histológico, se prepararon secciones en serie para su evaluación bajo microscopio óptico. Además, se midieron los diámetros de los glomérulos y el espacio glomerular, y se investigaron los cambios de los valores de todos los grupos con el tiempo de exposición. La acrilamida y sus derivados causaron daño intersticial glomerular, arteriolar y tubular en el tejido renal. El estrechamiento del espacio de los glomérulos, el aumento de la matriz mesangial difusa y la dilatación tubular se observó en algunos grupos. Además, también se observó dilatación, disociación del epitelio tubular, membranas basales espesantes y vacuolización glicogénica. Estos resultados adversos pueden deberse al monómero residual. No debe haber residuo de monómero en el polímero utilizado como biomateriales.
Descritores: Acrilamida/toxicidade
Rim/patologia
-Acrilatos/toxicidade
Materiais Biocompatíveis/toxicidade
Imuno-Histoquímica
Marcação In Situ das Extremidades Cortadas
Rim/efeitos dos fármacos
Polímeros
Ratos Wistar
Limites: Animais
Ratos
Responsável: CL1.1 - Biblioteca Central


  2 / 15 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Machado, Ana Lucia
Vergani, Carlos Eduardo
Texto completo
Id: lil-697640
Autor: Altieri, Karen Tereza; Sanita, Paula Volpato; Machado, Ana Lucia; Giampaolo, Eunice Teresinha; Pavarina, Ana Claudia; Jorge, Janaina Habib; Vergani, Carlos Eduardo.
Título: Eradication of a Mature Methicillin-Resistant Staphylococcus aureus (MRSA) Biofilm From Acrylic Surfaces
Fonte: Braz. dent. j;24(5):487-491, Sep-Oct/2013. tab.
Idioma: en.
Resumo: Methicillin-resistant Staphylococcus aureus (MRSA) can grow as structured biofilm in different surfaces, including oral mucosa and denture surfaces. Such biofilms can be released into the oral fluids and aspirated, causing systemic infections such as aspiration pneumonia. This study evaluated the efficacy of two disinfectant solutions and microwave irradiation in disinfecting acrylic specimens contaminated with MRSA biofilm. Thirty-six acrylic specimens were made, sterilized and contaminated with MRSA (107 cfu/mL). After incubation (37 °C/48 h), the specimens were divided into 4 groups: not disinfected (positive control); soaking in 1% sodium hypochlorite for 10 min; soaking in 2% chlorhexidine gluconate for 10 min; and irradiating by microwave for 3 min at 650 W. The viability of cells was evaluated by XTT reduction method. All specimens from the positive control group showed biofilm formation after 48 h incubation. The mean absorbance value of the control specimens was 1.58 (OD at 492 nm). No evidence of biofilm formation was observed on specimens after the disinfection methods. Disinfection by soaking in 1% sodium hypochlorite and 2% chlorhexidine gluconate and irradiating by microwaves resulted in 100% reduction of MRSA biofilm metabolism. The use of chemical solutions and microwave irradiation was shown to be effective for eradicating mature MRSA biofilms on acrylic resin specimens.

Staphylococcus aureus resistente à meticilina (MRSA, do inglês methicillin-resistant Staphylococcus aureus) pode crescer como biofilme estruturado em diferentes superfícies, incluindo mucosa bucal e superfícies de próteses. Estes biofilmes podem se dispersar nos fluidos orais e ser aspirados, causando infecções sistêmicas, como a pneumonia aspirativa. Este estudo avaliou a eficácia de duas soluções desinfetantes e irradiação por microondas na desinfecção de corpos-de-prova acrílicos contaminados com biofilme de MRSA. Trinta e seis espécimes de resina acrílica foram fabricados, esterilizados e contaminados com MRSA (107 ufc/mL). Após a incubação (37 °C/48 h), os espécimes foram divididos em quatro grupos: não desinfetados (controle positivo); imersos em hipoclorito de sódio 1% por 10 min; imersos em gluconato de clorexidina 2% por 10 min e irradiados por microondas durante 3 min a 650 W. A viabilidade das células foi avaliada pelo método de redução de XTT. Todos os espécimes do grupo controle apresentaram formação de biofilme após 48 h de incubação. O valor médio de absorbância destes espécimes foi de 1.58 (OD a 492 nm). Nenhuma evidência de formação de biofilme foi observada em todas as amostras desinfetadas. A desinfecção em hipoclorito de sódio 1%, gluconato de clorexidina 2% e irradiação em microondas resultou em 100% de redução do metabolismo do biofilme de MRSA. O uso de soluções químicas e irradiação em microondas mostrou-se eficaz na eliminação do biofilme maduro de MRSA sobre corpos-de-prova de resina acrílica.
Descritores: Acrilatos
Biofilmes
Desinfetantes/farmacologia
Micro-Ondas
Staphylococcus aureus Resistente à Meticilina/efeitos dos fármacos
-Clorexidina/farmacologia
Staphylococcus aureus Resistente à Meticilina/efeitos da radiação
Propriedades de Superfície
Hipoclorito de Sódio/farmacologia
Responsável: BR1.1 - BIREME


  3 / 15 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-662428
Autor: Lopes, Murilo Baena; Saquy, Paulo Cesar; Moura, Sandra Kiss; Wang, Linda; Graciano, Fabiana Mezzaroba Ortenzi; Correr Sobrinho, Lourenço; Gonini Júnior, Alcides.
Título: Effect of different surface penetrating sealants on the roughness of a nanofiller composite resin
Fonte: Braz. dent. j;23(6):692-697, 2012. ilus, tab.
Idioma: en.
Resumo: This study evaluated the effectiveness of different sealants applied to a nanofiller composite resin. Forty specimens of Filtek Z-350 were obtained after inserting the material in a 6x3 mm stainless steel mold followed by light activation for 20 s. The groups were divided (n=10) according to the surface treatment applied: Control group (no surface treatment), Fortify, Fortify Plus and Biscover LV. The specimens were subjected to simulated toothbrushing using a 200 g load and 250 strokes/min to simulate 1 week, 1, 3 and 6 months and 1 and 3 years in the mouth, considering 10,000 cycles equivalent to 1 year of toothbrushing. Oral-B soft-bristle-tip toothbrush heads and Colgate Total dentifrice at a 1:2 water-dilution were used. After each simulated time, surface roughness was assessed in random triplicate readings. The data were submitted to two-way ANOVA and Tukey's test at a 95% confidence level. The specimens were observed under scanning electron microscopy (SEM) after each toothbrushing cycle. The control group was not significantly different (p>0.05) from the other groups, except for Fortify Plus (p<0.05), which was rougher. No significant differences (p>0.05) were observed at the 1-month assessment between the experimental and control groups. Fortify and Fortify Plus presented a rougher surface over time, differing from the baseline (p<0.05). Biscover LV did not differ (p>0.05) from the baseline at any time. None of the experimental groups showed a significantly better performance (p>0.05) than the control group at any time. SEM confirmed the differences found during the roughness testing. Surface penetrating sealants did not improve the roughness of nanofiller composite resin.

Este estudo avaliou a efetividade de diferentes selantes aplicados a uma resina nanoparticulada. Quarenta espécimes de Filtek Z-350 foram obtidos depois da inserção do material em um molde de aço inoxidável seguido por fotoativação por 20 s. Os grupos foram divididos (n=10) de acordo com o tratamento superficial aplicado: Grupo controle (sem tratamento superficial), Fortify, Fortify Plus ou Biscover LV. Os espécimes foram submetidos a escovação simulada usando uma carga de 200 g e 250 ciclos/min para simular 1 semana, 1, 3 e 6 meses e 1 e 3 anos, considerando que 10.000 ciclos equivalem a um ano de escovação. Escovas Oral-B de cabeça macia e dentifrício Colgate Total diluído a 1:2 em água foram utilizados. Depois de cada período de simulação, a rugosidade superficial foi medida em triplicata. Os dados foram submetidos à ANOVA de dois fatores e ao teste de Tukey com nível de 95% de confiança. Os espécimes foram observados em microscopia eletrônica de varredura (MEV) depois de cada ciclo de escovação. O grupo controle não foi diferente (p>0,05) que os outros grupos, exceto pelo Fortify Plus (p<0,05), que foi mais rugoso. Nenhuma diferença (p>0,05) foi observada em 1 mês de simulação entre os grupos experimentais e o controle. Fortify e Fortify Plus apresentaram rugosidade regular com o tempo, diferindo da inicial em todos os tempos. Nenhum dos grupos selados mostrou melhor desempenho (p>0,05) que o grupo controle em qualquer um dos tempos. MEV ressaltou as diferenças encontradas durante o teste de rugosidade. Selantes de penetração de superfície não melhoram a rugosidade da resina nanoparticulada.
Descritores: Resinas Compostas/química
Materiais Dentários/química
Nanocompostos/química
Cimentos de Resina/química
-Acrilatos/química
Cura Luminosa de Adesivos Dentários
Teste de Materiais
Microscopia Eletrônica de Varredura
Polimerização
Estresse Mecânico
Propriedades de Superfície
Fatores de Tempo
Escovação Dentária/instrumentação
Cremes Dentais/química
Limites: Seres Humanos
Tipo de Publ: Estudo Comparativo
Ensaio Clínico Controlado Aleatório
Responsável: BR1.1 - BIREME


  4 / 15 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-491629
Autor: Quiñones, D; Ghaly, E. S.
Título: Formulation and characterization of nystatin gel
Fonte: P. R. health sci. j;27(1):61-67, Mar. 2008.
Idioma: en.
Resumo: The main objective of this research is to develop and characterize a series of carbopol 934 (CP) hydroxypropyl methylcellulose (HPMC) and a combination of carbopol-HPMC as a gel base for topical delivery of nystatin. The drug level was held constant at 1.72% w/w and the level of propylene glycol which is used as a co-solvent and penetration enhancer was also kept constant at 2% w/w. The total level of the polymer was held constant at 1.5% w/w as a single polymer or combination of two polymers. The polymers combination selected were: carbopol 934 to HPMC at a ratio of 0:1, 1:0, 1:2, 2:1 and 1:1. The batch size was 500 g and triethanolamine was used to adjust the pH of the gel. The rheological study showed that formulation containing combination of 2 carbopol and 1 HPMC ratio gave the highest viscosity, and exhibited an apparent pseudoplastic thixotropic behavior. The diffusion study indicated that gel formulation containing carbopol-HPMC at a ratio of 2:1 gave the highest percent drug diffusion compared to formulation containing low carbopol to HPMC ratio, carbopol alone or HPMC alone. Both in-vitro release and rheological study indicated that carbopol-HPMC had the best gel strength, physical properties and ability to diffuse the drug than carbopol or HPMC alone. The results obtained in this study demonstrated that the combination of carbopol and hydroxypropyl methylcellulose can be used as a gel vehicle for nystatin topical application.
Descritores: Nistatina
-Acrilatos
Administração Tópica
Química Farmacêutica
Química Física
Géis
Metilcelulose/análogos & derivados
Nistatina/química
Responsável: BR1.1 - BIREME


  5 / 15 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-481130
Autor: Gernhardt, Christian Ralf; Bekes, Katrin; Hahn, Petra; Schaller, Hans-Günter.
Título: Influence of pressure application before light-curing on the bond strength of adhesive systems to dentin
Fonte: Braz. dent. j;19(1):62-67, 2008. ilus.
Idioma: en.
Resumo: This study evaluated the influence of defined pressure application before light-curing on the tensile bond strength (TBS) of two adhesive systems to wet and perfused dentin. Bonding sites were analyzed by scanning electron microscopy (SEM) to assess morphological changes. Dentin discs from 120 human third molars were prepared in such a way to allow simulation of intrapulpal pressure. The specimens were randomly assigned to 6 groups (n=20) according to different experimental conditions. The adhesive systems (ScotchbondTM Multi-Purpose and Syntac®) were applied either to wet or perfused dentin. In the latter, compression was applied before adhesive light-curing . TBS was recorded using an universal testing machine. Qualitative examination of the bonding sites was performed by SEM after dissolving the dentin with 50 percent nitric acid. Pressure application prior to light-curing resulted in a remarkable decrease of TBS for Syntac®, while no significant change was observed for ScotchbondTM MP. SEM analysis showed no considerable lengthening of the resin tags after pressure application. These findings suggest that application of adhesive systems to dentin under pressure before light-curing had no positive effect on TBS.

Este estudo avaliou a influência da aplicação de uma pressão definida antes da polimerização sobre a resistência à tração de dois sistemas adesivos à dentina molhada e perfundida. Os sítios de adesão foram analisados em microscopia eletrônica de varredura (MEV) a fim de determinar a ocorrência de alterações morfológicas. Discos de dentina de 120 terceiros molares humanos foram preparados de tal forma a simular a pressão intrapulpar. Os espécimes foram alocados aleatoriamente em 6 grupos (n=20), de acordo com as diferentes condições experimentais propostas. Os sistemas adesivos (Syntac® e ScotchbondTM Multi-Purpose) foram aplicados sobre a dentina molhada ou perfundida. Nesta última, compressão (7 N) foi aplicada antes da polimerização do sistema adesivo. A resistência à tração foi registrada em máquina universal de ensaios. A análise qualitativa dos sítios de adesão foi realizada em MEV após dissolução da dentina em 50 por cento de ácido nítrico. A aplicação da pressão antes da polimerização do sistema adesivo resultou em diminuição significativa da resistência à tração do Syntac®, ao passo que para o ScotchbondTM MP nenhuma alteração significativa foi observada. A análise em MEV não mostrou aumento considerável do tamanho dos tags de resina após a aplicação da pressão. Esses achados sugerem que a aplicação de sistemas adesivos à dentina sob pressão previamente à polimerização não teve efeito positivo sobre a resistência à tração.
Descritores: Adesivos Dentinários/química
Dentina/ultraestrutura
Cura Luminosa de Adesivos Dentários
-Acrilatos/química
Resinas Acrílicas/química
Resinas Compostas/química
Permeabilidade da Dentina
Polpa Dentária/fisiologia
Luz
Teste de Materiais
Microscopia Eletrônica de Varredura
Pressão
Cimentos de Resina/química
Estresse Mecânico
Propriedades de Superfície
Resistência à Tração
Molhabilidade
Água/química
Limites: Seres Humanos
Tipo de Publ: Estudo Comparativo
Ensaio Clínico Controlado Aleatório
Responsável: BR1.1 - BIREME


  6 / 15 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-466848
Autor: Urban, Vanessa Migliorini.
Título: Efeito de tratamentos pós-polimerização sobre o peso molecular, o grau de conversão, a temperatura de transição vítrea e a liberação in vitro de monômero residual, plastificante e produtos de degradação de resinas acrílicas para reembasamento imediato / Effect of post-polymerization treatments on molecular weight, degree of conversion, glass transition temperature, and in vitro leachability of residual monomer, plasticizer, and degradation products of hard chairside reline resins.
Fonte: Araraquara; s.n; 2007. 228 p. ilus, graf.
Idioma: pt.
Tese: Apresentada a Universidade Estadual Paulista. Faculdade de Odontologia de Araraquara para obtenção do grau de Doutor.
Resumo: Os objetivos deste estudo foram avaliar: 1. o efeito de tratamentos póspolimerização (MW-irradiação por energia de microondas e WB-imersão em água aquecida) sobre o grau de conversão (DC) de resinas acrílicas para reembasamento imediato (Ufi Gel hard-U, Kooliner-K e Tokuso Rebase Fast-T) e de uma resina acrílica para base de prótese (Lucitone 550-L), submetida a dois ciclos de polimerização (LS-curto e LL-longo) por espectroscopia FT-Raman; 2. o peso molecular (M w) do pré-polímero dos materiais U, K, T e L e das amostras polimerizadas da resina K (controle; MW e WB) por GPC; 3. o efeito de MW e WB na temperatura de transição vítrea (Tg) das resinas para reembasamento imediato (Duraliner II-D, K, New Truliner-N, U e T) e da resina para base de prótese (LS e LL) por DSC; 4. o efeito de WB na liberação de compostos residuais (isobutil metacrilato-IBMA, 1,6-hexanediol dimetacrilato-1,6-HDMA e DBNP-dibutil-n-ftalato) a partir das resinas para reembasamento imediato K, N, U e T para saliva artificial por CLAE; 5. o efeito de WB na liberação de produtos de degradação (ácido metacrílico-MA e ácido benzóico-BA) a partir das resinas para reembasamento imediato K, N, U e T para saliva artificial por CLAE. Amostras do grupo controle não foram submetidas a nenhum tratamento. Os resultados de DC (porcentagem) foram analisados pelo teste de Kruskal-Wallis (_=0,05). Os resultados de Tg (ºC) foram analisados pela análise de variância (ANOVA), seguido pelo teste de Tukey (_=0,05)...
Descritores: Acrilatos
Cromatografia em Gel
Cromatografia Líquida
Saliva Artificial
Responsável: BR39.2 - Biblioteca Professora Maria Dilma de Oliveira Gonçalves
BR39.2, U72e


  7 / 15 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-295083
Autor: Arroyo Muñoz, Leticia; Villaseñor Gudiño, Felipe.
Título: Evolución de las lentes intraoculares y los viscoelásticos / Intraocular lenses and viscoelastic evolution review
Fonte: Rev. mex. oftalmol;74(5):252-5, sept.-oct. 2000. CD-ROM.
Idioma: es.
Resumo: Se hace una revisión de la literatura y se relata la evolución de las lentes intraoculares, de sus materiales y diseños, así como de los viscoelásticos.
Descritores: Acrilatos/uso terapêutico
Elastômeros de Silicone/uso terapêutico
Hidrogel de Polietilenoglicol-Dimetacrilato/uso terapêutico
Lentes Intraoculares/tendências
Metacrilatos/uso terapêutico
-Ácidos Polimetacrílicos/uso terapêutico
Materiais Biocompatíveis/uso terapêutico
Tipo de Publ: Revisão
Responsável: MX1.1 - CENIDSP - Centro de Información para Decisiones en Salud Pública


  8 / 15 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-240709
Autor: Bustos, Norma; Brizuela, Claudia; Quirós, Enrique J.
Título: Comparación in vitro de conos de acrílico y conos de gutapercha en la obturación de conductos curvos / An in vitro comparison between acrylic and gutta-percha cones in the obturation of curved canals
Fonte: Prisma;3(4):10-3, dic. 1998. ilus.
Idioma: es.
Descritores: Guta-Percha/química
Técnicas In Vitro
Obturação do Canal Radicular/instrumentação
Materiais Restauradores do Canal Radicular
-Acrilatos/química
Distribuição de Qui-Quadrado
Cavidade Pulpar/anatomia & histologia
Hipoclorito de Sódio/uso terapêutico
Responsável: AR29.1 - Biblioteca


  9 / 15 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-231862
Autor: Barreda, Graciela.
Título: Cementado y adhesión en ortodoncia / Cementation and bonding in orthodontics
Fonte: Ortodoncia;61(121/122):57-60, 1997. ilus, tab.
Idioma: es.
Resumo: Hemos desarrollado extensamente lo referido a los ionómeros vítreos porque pensamos que, en su forma tradicional o en las de más reciente desarrollo, es un excelente material que ha mejorado la performance clínica de los antiguos cementos utilizados para el cementado de bandas de ortodoncia
Descritores: Aparelhos Ortodônticos/normas
Cimentação/instrumentação
Cimentação/métodos
Colagem Dentária
-Ácidos Fosfóricos/química
Acrilatos/química
Cimentos de Ionômeros de Vidro/classificação
Cimentos de Ionômeros de Vidro/química
Fluoretos/farmacologia
Ataque Ácido Dentário/métodos
Cimento de Policarboxilato/química
Cimentos de Resina/química
Braquetes Ortodônticos
Propriedades de Superfície
Resistência à Tração
Cimento de Fosfato de Zinco/química
Responsável: AR29.1 - Biblioteca


  10 / 15 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Id: lil-224727
Autor: Lucino, Sergio; Zunino, Silvia; Castellari, Mario; Bobone, Fernando; Pachon, Oscar.
Título: Braquiterapia en vía biliar: tratamiento percutáneo de complicación hemorrágica / Brachitherapy of bile ducts: percutaneous treatment
Fonte: Rev. argent. radiol;62(3):231-4, jul.-sept. 1998. ilus.
Idioma: es.
Resumo: Objetivo: presentar una complicación poco común en el tratamiento oncológico mediante braquiterapia con Ir192 del colangiocarcinoma y su tratamiento mediante embolización endovascular. Material y método: hombre de 74 años de edad, portador de colangiocarcinoma en canal hepático común. Ingresa a protocolo de braquiterapia con Ir192. Se administran 40 Gy en dos sesiones de 20 Gy. Siete días luego de la segunda sesión comienza con hemorragia digestiva severa, comprometiendo la vida del paciente. En un episodio de sangrado, a través del catéter biliar se objetiva un pseudoaneurisma de la arteria hepética comunicando con la vía biliar. Se decide arteriografía hepática y embolización con Histoacryl. Resultados: la embolización ocluyó la rama derecha de la arteria hepática y el pseudoaneurisma, cohibiendo inmediatamente la hemorragia. El paciente regresa a Unidad de Terapia Intensiva. Diez días posteriores es dado de alta. Conclusión: la angiografía y embolización constituyen procedimientos confiables en el diagnóstico y tratamiento de esta complicación hemorrágica secundarias a braquiterapia de tumores en la vía biliar
Descritores: Braquiterapia/efeitos adversos
Colangiocarcinoma/radioterapia
Hemorragia Gastrointestinal/etiologia
-Acrilatos/uso terapêutico
Adenocarcinoma/radioterapia
Embolização Terapêutica/métodos
Hemorragia Gastrointestinal/terapia
Limites: Seres Humanos
Masculino
Idoso
Tipo de Publ: Relatos de Casos
Responsável: AR144.1 - CIBCHACO - Centro de Información Biomedica del Chaco



página 1 de 2 ir para página        
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde