Base de dados : LILACS
Pesquisa : D03.633.300.953.600 [Categoria DeCS]
Referências encontradas : 30 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 3 ir para página          

  1 / 30 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-792589
Autor: WANG, Linda; BIM JÚNIOR, Odair; LOPES, Adolfo Coelho de Oliveira; FRANCISCONI-DOS-RIOS, Luciana Fávaro; MAENOSONO, Rafael Massunari; D’ALPINO, Paulo Henrique Perlatti; HONÓRIO, Heitor Marques; ATTA, Maria Teresa.
Título: Water interaction and bond strength to dentin of dye-labelled adhesive as a function of the addition of rhodamine B
Fonte: J. appl. oral sci;24(4):317-324, July-Aug. 2016. tab, graf.
Idioma: en.
Projeto: São Paulo Research Foundation; . São Paulo Research Foundation.
Resumo: ABSTRACT Objective This study investigated the effect of the fluorescent dye rhodamine B (RB) for interfacial micromorphology analysis of dental composite restorations on water sorption/solubility (WS/WSL) and microtensile bond strength to dentin (µTBS) of a 3-step total etch and a 2-step self-etch adhesive system. Material and Methods The adhesives Adper Scotchbond Multi-Purpose (MP) and Clearfil SE Bond (SE) were mixed with 0.1 mg/mL of RB. For the WS/WSL tests, cured resin disks (5.0 mm in diameter x 0.8 mm thick) were prepared and assigned into four groups (n=10): MP, MP-RB, SE, and SE-RB. For µTBS assessment, extracted human third molars (n=40) had the flat occlusal dentin prepared and assigned into the same experimental groups (n=10). After the bonding and restoration procedures, specimens were sectioned in rectangular beams, stored in water and tested after seven days or after 12 months. The failure mode of fractured specimens was qualitatively evaluated under optical microscope (x40). Data from WS/WSL and µTBS were assessed by one-way and three-way ANOVA, respectively, and Tukey’s test (α=5%). Results RB increased the WSL of MP and SE. On the other hand, WS of both MP and SE was not affected by the addition of RB. No significance in µTBS between MP and MP-RB for seven days or one year was observed, whereas for SE a decrease in the µTBS means occurred in both storage times. Conclusions RB should be incorporated into non-simplified DBSs with caution, as it can interfere with their physical-mechanical properties, leading to a possible misinterpretation of bonded interface.
Descritores: Rodaminas/química
Água/química
Adesivos Dentinários/química
Dentina/efeitos dos fármacos
Corantes Fluorescentes/química
-Solubilidade
Propriedades de Superfície
Resistência à Tração
Fatores de Tempo
Teste de Materiais
Reprodutibilidade dos Testes
Colagem Dentária/métodos
Microscopia Confocal
Resinas Compostas/química
Cimentos de Resina/química
Falha de Restauração Dentária
Limites: Seres Humanos
Tipo de Publ: Estudos de Avaliação
Responsável: BR1.1 - BIREME


  2 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-880165
Autor: Bim Junior, Odair.
Título: Efeito de adição de rodamina B e fluoresceína sódica a sistemas adesivos não simplificados: aspectos fotofísicos e físico-químicos / Effect of addition of rhodamine B and fluorescein to conventional etch-and-rinse and self-etching adhesive systems: photophysical and physical-chemical aspects.
Fonte: Bauru; s.n; 2017. 143 p. tab, ilus, graf.
Idioma: pt.
Tese: Apresentada a Universidade de São Paulo. Faculdade de Odontologia de Bauru para obtenção do grau de Doutor.
Resumo: A adição de corantes fluorescentes a adesivos odontológicos possibilita a investigação da distribuição espacial desses materiais na interface dente-restauração, utilizando-se a microscopia confocal de varredura a laser (MCVL). A literatura indica falta de padronização na aplicação de agentes fluorescentes com tal finalidade. Esse estudo sistematizou estratégias para a adição de rodamina B (RB) e fluoresceína sódica (FS) a um sistema adesivo convencional de três passos, Adper Scotchbond Multi-Purpose (MP), e um autocondicionante de dois passos, Clearfil SE Bond (SE), considerados "padrão-ouro" na Odontologia. Os objetivos principais foram (a) determinar a menor faixa de concentrações de RB e FS necessária para produzir imagens satisfatórias da interface dentina-adesivo e (b) avaliar o efeito da adição desses corantes sobre algumas propriedades das resinas. Os adesivos foram marcados com RB ou FS em concentrações decrescentes (0,5, 0,1, 0,02 e 0,004 mg/mL) por meio de um método de dispersão semidireto. O comportamento fotofísico/ fluorescente dos adesivos marcados foi investigado por espectroscopia de fotoluminescência e MCVL. Paralelamente, avaliaram-se os adesivos quanto ao grau de conversão (GC) e ao ângulo de contato (AC). Tanto os resultados de GC como os de AC foram submetidos à análise de variância com dois fatores (adesivo e tratamento) com α = 0,05, seguida de teste post-hoc de Tukey. Os máximos comprimentos de onda de emissão e de excitação da RB e da FS foram influenciados pelo meio polimérico e pela concentração de corante de modo geral. A MCVL preliminar de amostras de adesivo polimerizado, realizada sob condições experimentais padronizadas, mostrou que o comportamento fluorescente da RB em MP e SE foi muito semelhante na mesma concentração de corante, mas o mesmo não pôde ser dito do comportamento da FS, que foi notavelmente inferior no adesivo autocondicionante, SE, na concentração mais alta. Em dentina, os adesivos preparados com RB nas concentrações-alvo de 0,1 e 0,02 mg/mL apresentaram fluorescência ótima; já aqueles preparados com 0,004 mg/mL produziram fraco sinal. Adesivos preparados com FS a 0,5 mg/mL apresentaram ótima fluorescência na interface de adesão, enquanto que concentração menor desse corante não produziu sinal suficiente. Padrões morfológicos aparentemente atípicos foram observados na interface de adesão, quando da associação do adesivo SE com o corante FS. A adição de RB e FS nas quatro concentrações indicadas aos adesivos MP e SE não afetou o GC nem o AC em comparação com os grupos de controle correspondentes. Em suma, a RB mostra-se um corante mais versátil que a FS na avaliação morfológica das interfaces dentina-MP e dentina-SE via MCVL. A menor faixa de concentrações de RB nos adesivos MP e SE, na qual é possível produzir imagens satisfatórias das interfaces, situa-se entre 0,1­0,02 mg/mL. Já o corante FS deve ser adicionado a esses adesivos a pelo menos 0,5 mg/mL para produzir níveis de fluorescência satisfatórios na interface de adesão. A não ocorrência de efeitos deletérios sobre a polimerização e a molhabilidade das resinas estabelece uma margem de segurança para a incorporação desses agentes fluorescentes (em concentração ≤ 0,5 mg/mL) nesses sistemas monoméricos.(AU)

The addition of fluorescent dyes to dental adhesives makes it possible to investigate the spatial distribution of such resin-based materials in the tooth-restoration interface, using confocal laser scanning microscopy (CLSM). Literature indicates a lack of standardization on the application of fluorescent agents for this purpose. This work presents strategies for adding rhodamine B (RB) and fluorescein sodium salt (FS) to a three-step etch-and-rinse adhesive system, Adper Scotchbond Multi-Purpose (MP), and a two-step self-etching one, Clearfil SE Bond (SE), both regarded as "gold standard" in restorative dentistry. The main objectives were (a) to determine the lowest range of RB and FS concentrations required to produce suitable images of the dentin-adhesive interface via CLSM and (b) to investigate potential effects of addition of these dyes on some resin properties. The adhesives were labeled with RB or FS at decreasing concentrations (0.5, 0.1, 0.02 and 0.004 mg/mL) by means of a semi-direct dispersion method. The photophysical/fluorescent behavior of the labeled resins was investigated by photoluminescence spectroscopy and by CLSM. The adhesives were also investigated with regards to the degree of conversion (DC) and contact angle (CA). A two-way ANOVA of "adhesive" and "treatment" was conducted on DC and CA separately, followed by Tukey's test. The maximum emission and excitation wavelengths of RB and FS were influenced by the host polymer and the dye concentration in general. The preliminary CLSM of cured adhesive samples, performed with standardized settings, showed that the fluorescent behavior of RB in MP and SE was very similar in the same dye concentration, unlike the behavior of FS, which was lower in the self-etching adhesive for the highest dye concentration. In dentin, the adhesives prepared with RB at the target concentrations of 0.1 and 0.02 mg/mL presented optimal fluorescence; those with 0.004 mg/mL produced poor signal. Adhesives prepared with FS at 0.5 mg/mL presented optimal fluorescence at the bonding interface, whereas lower concentrations of FS did not produce sufficient signal. Atypical morphological features were observed at the bonding interface, when adhesive SE was used with FS. The addition of RB and FS at the four decreasing concentrations to adhesives MP and SE did not affect DC or CA compared to the corresponding controls. In short, RB is more versatile than FS for the morphological characterization of dentin-MP and dentin-SE interfaces via MCVL. The lowest range of RB concentrations in adhesives MP and SE that can produce suitable images of the bonding interface lies between 0.1­0.02 mg/mL. The dye FS should be added to these adhesives at 0.5 mg/mL at least to produce satisfactory fluorescence levels at the bonding interface. Since negative effects on polymerization and wettability of the resins were not observed, the use of RB and FS (in concentration ≤ 0.5 mg/mL) together with MP and SE should be reliable in terms of resin properties.(AU)
Descritores: Fluoresceína/química
Corantes Fluorescentes/química
Cimentos de Resina/química
Rodaminas/química
-Análise de Variância
Etanol/química
Microscopia Confocal
Valores de Referência
Reprodutibilidade dos Testes
Autocura de Resinas Dentárias/métodos
Espectrometria de Fluorescência
Espectrofotometria Infravermelho
Responsável: BR28.1 - Serviço de Biblioteca e Documentação Professor Doutor Antônio Gabriel Atta
BR28.1, B51e


  3 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: biblio-850615
Autor: Assis, Neuza Maria Souza Picorelli; Gomes, Ana Paula Martins; Kubo, Claudio Hideki; Mancini, Maria Nadir Gasparoto.
Título: Avaliação do contato de dois materiais retrobturadores na densidade óptica decorantes tamponados e não tamponados / Evaluation of the contact of two retrofilling materials on optical density of buffered and unbuffered dyes
Fonte: Ciênc. odontol. bras;10(02):75-84, Abr./jun.2007.
Idioma: pt.
Resumo: O objetivo deste trabalho foi avaliar a densidade óptica das soluções corantes azul de metileno 2% tamponada e nãotamponada, rodamina B 2% tamponada e não tamponada, antes e após a imersão de dois materiais retrobturadores por diferentes períodos de tempo. As soluções corantes, sem a imersão dos espécimes, foram analisadas nos períodos de 0,12, 24, 48 e 72 horas. Foram preparados oitenta espécimes de cimento Sealer 26 e oitenta de cimento de Portland, os quais foram imersos em 0,7 ml de cada uma das soluções corantes e avaliados nos períodos de tempo de 12, 24, 48 e 72 horas. A densidade óptica foi avaliada em espectrofotômetro ajustado em 596nm para o azul de metileno e 566nmpara a rodamina B. Os dados obtidos foram analisados através dos testes ANOVA (3 fatores) e Tukey 5%. Os resultados mostraram que houve diferença estatisticamente significativa nos valores da densidade óptica do azul de metileno 2% tamponado após a imersão do Sealer 26 nos períodos de 24, 48 e 72 horas em relação ao tempo de 12 horas. Houve diferença estatisticamente significativa nos valores da densidade óptica da rodamina B 2% tamponada após a imersão do cimento de Portland nos períodos de 12, 24 e 48 horas em relação ao tempo de 72 horas. Pôde-se verificar que as soluções corantes não tamponadas apresentaram valores menores de densidade óptica. Dentre as soluções corantes analisadas,a rodamina B 2% tamponada apresentou comportamento mais estável quanto aos valores de densidade ópticaaté o período de avaliação de 48 horas.
Descritores: Corantes
Materiais Dentários
Materiais Restauradores do Canal Radicular
-Análise de Variância
Azul de Metileno
Rodaminas
Responsável: BR243.1 - Serviço Técnico de Biblioteca e Documentação


  4 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: biblio-850611
Autor: Araújo, Gustavo Sivieri; Bortoluzzi, Eduardo Antunes; Tanomaru, Juliane Maria Guerreiro; Berbert, Fábio Luiz Camargo Villela; Tanomaru Filho, Mário.
Título: Selamento apical em obturações retrógradas. Estudo em dentes bovinos empregando solução corante Rodamina B / Apical sealing in retrograde fillings. Study in bovine teeth using Rhodamine B dye solution
Fonte: Ciênc. odontol. bras;10(02):45-53, Abr./jun.2007.
Idioma: pt.
Resumo: A capacidade de selamento de materiais utilizados em endodontia tem sido avaliada por testes de infiltração com corantes. A proposta deste estudo foi avaliar o selamento apical de materiais utilizados em obturações retrógradas empregando modelo experimental com dentes bovinos. Quarenta incisivos bovinos recém extraídos, com raízes retas tiveram seus canais radiculares instrumentados e obturados. Após a secção da porção apical, cavidades retrógradas foram preparadascom pontas de retropreparo ultra-sônico e os dentes divididos aleatoriamente em três grupos experimentais (n=12) equatro controles (n=4). Foram utilizados os materiais: Grupo I - MTA Angelus Cinza; Grupo II - Cimento de Óxido Zinco e Eugenol; Grupo III - Sealer 26. Em seguida, os dentes foram imersos em solução de Rodamina B a 0,2 % por 48 horas em ambiente com vácuo. Decorrido este período, os dentes foram seccionados longitudinalmente e as imagens digitalizadas analisadas por meio do programa Image Tool. Grupos controle positivo e negativo apresentaram infiltração máxima ou zero, respectivamente. Os resultados obtidos foram submetidos ao teste ANOVA e de Tukey demonstrandomenor infiltração apical para o Sealer 26 (p<0,05). MTA e OZE apresentaram infiltração apical semelhante (p>0,05).Conclui-se que o cimento Sealer 26 proporciona selamento apical superior ao MTA e OZE, sendo o modelo experimental com dentes bovinos viável para a avaliação do selamento apical em obturações retrógradas.
Descritores: Infiltração Dentária
Endodontia
Obturação Retrógrada
Materiais Restauradores do Canal Radicular
-Análise de Variância
Rodaminas
Limites: Bovinos
Animais
Responsável: BR243.1 - Serviço Técnico de Biblioteca e Documentação


  5 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-792592
Autor: FERNANDES, Ana Paula; JUNQUEIRA, Marina de Azevedo; MARQUES, Nádia Carolina Teixeira; MACHADO, Maria Aparecida Andrade Moreira; SANTOS, Carlos Ferreira; OLIVEIRA, Thais Marchini; SAKAI, Vivien Thiemy.
Título: Effects of low-level laser therapy on stem cells from human exfoliated deciduous teeth
Fonte: J. appl. oral sci;24(4):332-337, July-Aug. 2016. graf.
Idioma: en.
Resumo: ABSTRACT Low-Level Laser Therapy stimulates the proliferation of a variety of types of cells. However, very little is known about its effect on stem cells from human exfoliated deciduous teeth (SHED). Objective This study aimed to evaluate the influence of different laser therapy energy densities on SHED viability and proliferation. Material and Methods SHED were irradiated according to the groups: I (1.2 J/cm2 - 0.5 mW – 10 s), II (2.5 J/cm2 – 10 mW – 10 s), III (3.7 J/cm2 – 15 mW – 10 s), IV (5.0 J/cm2 – 20 mW – 10 s), V (6.2 J/cm2 – 25 mW – 10 s), and VI (not irradiated – control group). Cell viability was assessed 6 and 24 h after irradiation measuring the mitochondrial activity and using the Crystal Violet assay. Cell proliferation was assessed after 24, 48, and 72 h of irradiation by SRB assay. Results MTT assay demonstrated differences from 6 to 24 hours after irradiation. After 24 h, groups I and IV showed higher absorbance values than those of control group. Crystal Violet assay showed statistically differences in the absorbance rate from 6 to 24 h after irradiation for groups III and VI. At 24 h after irradiation, Group III absorbance rate was greater than that of groups I, II, and IV. Group VI absorbance rate was greater than that of groups I and IV. SRB assay showed that the group I had higher rates than those of groups II, III, V, and VI, at 24 h after irradiation. After 48 h, group I exhibited the greatest cell proliferation rate followed by groups III, V, and VI. After 72 h, group III exhibited the lowest cell proliferation rate than those of groups II, IV, and V. Conclusions The Low-Level Laser Therapy energy densities used in this study did not cause loss of cell viability and stimulated SHED proliferation within the parameters described in this study.
Descritores: Terapia com Luz de Baixa Intensidade/métodos
Células-Tronco/efeitos da radiação
Esfoliação de Dente
Dente Decíduo/citologia
Dente Decíduo/efeitos da radiação
-Análise de Variância
Proliferação Celular/efeitos da radiação
Sobrevivência Celular/efeitos da radiação
Células Cultivadas
Formazans
Dose de Radiação
Reprodutibilidade dos Testes
Rodaminas
Sais de Tetrazólio
Fatores de Tempo
Limites: Seres Humanos
Tipo de Publ: Estudos de Avaliação
Responsável: BR1.1 - BIREME


  6 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-735832
Autor: Rossi-Fedele, Giampiero; Guastalli, Andrea R.
Título: Effect of an Alcohol-Based Caries Detector on the Surface Tension of Sodium Hypochlorite Preparations
Fonte: Braz. dent. j;26(1):66-68, Jan-Feb/2015. tab.
Idioma: en.
Resumo: The purpose of this study was to evaluate the effect of an alcohol-based caries detector (Kurakay) on the surface tension of a conventional sodium hypochlorite (NaOCl) preparation, and a product containing a surface-active agent (Chlor-XTRA). The surface tensions of the following solutions were tested: NaOCl, a mixture of NaOCl and Kurakay 9:1 w/w, Chlor-XTRA, a mixture of Chlor-XTRA and Kurakay 9:1 w/w. Ten measurements per test solution were made at 20 C, using an optical method called the "Pendant drop method", with a commercially available apparatus. The addition of Kurakay reduced the surface tension for NaOCl (p<0.05) whilst no significant difference was detected for Chlor-XTRA (p>0.05). Statistically significant differences between the NaOCl and Chlor-XTRA groups were found (p<0.05). The addition of an alcohol-based caries detector resulted in a reduction of the original surface tension values for NaOCl only. Taking into account the fact that mixtures of NaOCl and Kurakay have been used to assess the penetration of root canal irrigants in vitro, the related changes in surface tension are a possible source of bias.

O objetivo deste estudo foi avaliar o efeito de um detector de cárie com álcool (Kurakay) sobre a tensão superficial de um preparado convencional de hipoclorito de sódio (NaOCl) e um produto contendo um agente surfactante (Chlor-XTRA). Foram testadas as tensões superficiais das seguintes soluções: NaOCl, uma mistura de NaOCl e Kurakay na proporção de 9:1 em peso, Chlor-XTRA e um mistura de Chlor-XTRA e Kurakay na proporção de 9:1 em peso. Dez medidas foram feitas com cada solução, a 20 °C, utilizando um método óptico chamado "Método da gota pendente" (Pendant drop method) usando aparelhos disponíveis. Adição do Kurakay reduziu a tensão superficial do NaOCl (p<0,05), mas não houve diferença significante para Chlor-XTRA (p>0,05). Foram encontradas diferenças estatisticamente significantes entre os grupos NaOCl e Chlor-XTRA (p<0,05). Adição de um detector de cárie com álcool resultou na diminuição do valor original da tensão superficial apenas para NaOCl. Considerando que as misturas de NaOCl e Kurakay tem sido usadas para estudar a penetração in vitro dos irrigantes radiculares, as diferenças acima são uma possível fonte de desvio nos resultados.
Descritores: Etanol/química
Propilenoglicóis/química
Rodaminas/química
Irrigantes do Canal Radicular/química
Hipoclorito de Sódio/química
Tensoativos/química
-Soluções
Tensão Superficial
Responsável: BR1.1 - BIREME


  7 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Bernabé, Pedro Felicio Estrada
Texto completo
Id: lil-675667
Autor: Brazilian Dental Journal; Bernabé, Pedro Felício Estrada; Gomes-Filho, João Eduardo; Bernabé, Daniel Galera; Nery, Mauro Juvenal; Otoboni-Filho, José Arlindo; Dezan-Jr, Eloi; Cintra, Luciano Tavares Angelo.
Título: Sealing Ability of MTA Used as a Root End Filling Material: Effect of the Sonic and Ultrasonic Condensation
Fonte: Braz. dent. j;24(2):107-110, Mar-Apr/2013. graf.
Idioma: en.
Resumo: Despite the excellent properties of mineral trioxide aggregate (MTA), the condensation technique may have some influence in its sealing ability. The purpose of this study was to compare the sealing ability of sonic and ultrasonic setting of MTA. Thirty-four extracted human teeth had their canals prepared and filled with Sealapex sealer and gutta-percha using the active lateral condensation technique. The teeth were rendered waterproof and apicoectomy performed at 3 mm from the apex. Root-end cavities (3.0 mm deep and 1.4 mm diameter) were prepared with diamond ultrasonic tips. The root-end cavities were filled with Pro-Root MTA® with ultrasonic vibration, sonic vibration or no vibration. The positive control group did not receive any material while the negative control group was totally rendered waterproof. After material set, the specimens were immersed in Rodhamine B for 24 h, under vacuum in the first 15 min, then washed, dried and split longitudinally for evaluating the infiltration at the dentin/material interface. Data were analyzed using ANOVA and Tukey's tests at 5% significance level. Sonic vibration promoted the lowest infiltration values (p<0.05). It was concluded that sonic vibration could be considered an efficient aid to improve the sealing ability of MTA when used as root-end filling material.

Resumo O objetivo deste estudo foi avaliar in vitro, a influência da vibração sônica e ultrassônica no selamento marginal proporcionado pelo MTA. Trinta e quatro dentes humanos tiveram seus canais radiculares instrumentados e obturados com cimento Sealapex® pela técnica da condensação lateral ativa. Os dentes foram impermeabilizados e seccionados os 3 mm apicais. Retrocavidades (3 mm de profundidade e 1,4 mm de diâmetro) foram preparadas com pontas ultrassônicas diamantadas. As retrocavidades foram preenchidas com Pro-Root MTA® com auxílio da vibração ultrassônica, com auxílio da vibração sônica e sem vibração alguma. O grupo controle positivo não recebeu material retrobturador, enquanto que o negativo foi totalmente impermeabilizado. Após a presa do material, os espécimes foram mergulhados em Rodamina B por 15 min em vácuo, permanecendo nesta solução por mais 24 h. Em seguida, foram lavados, secados e clivados longitudinalmente para avaliação da infiltração do corante na interface dentina/material retrobturador. Os dados foram analisados utilizando a análise de variância e o teste de Tukey (p<0,05). Observou-se que apenas a vibração sônica foi diferente apresentando os menores índices de infiltração. Pode-se concluir que vibração sônica contribui com a melhora da capacidade de selamento marginal proporcionado pelo MTA quando empregado como material retrobturador. .
Descritores: Compostos de Alumínio/uso terapêutico
Compostos de Cálcio/uso terapêutico
Colagem Dentária
Óxidos/uso terapêutico
Obturação Retrógrada/métodos
Materiais Restauradores do Canal Radicular/uso terapêutico
Silicatos/uso terapêutico
-Apicectomia/métodos
Hidróxido de Cálcio/uso terapêutico
Combinação de Medicamentos
Dentina/ultraestrutura
Diamante/química
Corantes Fluorescentes
Guta-Percha/uso terapêutico
Rodaminas
Preparo de Canal Radicular/instrumentação
Preparo de Canal Radicular/métodos
Sonicação
Propriedades de Superfície
Salicilatos/uso terapêutico
Fatores de Tempo
Ultrassom/instrumentação
Vibração
Limites: Seres Humanos
Tipo de Publ: Estudo Comparativo
Ensaio Clínico Controlado Aleatório
Responsável: BR1.1 - BIREME


  8 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Sinhoreti, Mário Alexandre Coelho
Texto completo
Id: lil-662425
Autor: Medina, Alberth David Correa; Paula, Andréia Bolzan de; Fucio, Suzana Beatriz Portugal de; Puppin-Rontani, Regina Maria; Correr-Sobrinho, Lourenço; Sinhoreti, Mário Alexandre Coelho.
Título: Marginal adaptation of indirect restorations using different resin coating protocols
Fonte: Braz. dent. j;23(6):672-678, 2012. ilus, tab.
Idioma: en.
Projeto: Fundação de Amparo a Pesquisa do Estado de São Paulo.
Resumo: This study evaluated the influence of material combinations used in the resin coating technique (RCT) on the marginal adaptation of indirect restorations with gingival margins in enamel (EM) and cement (CM). Eighty third-molars were used. Two cavities were prepared in each tooth. The cavities were distributed into 16 groups. Cavities with EM were filled with the following material combinations: G1: Single-Bond 2 (Sb2), G2: Sb2 + Bond/Scotchbond-Multipurpose (Sb2B), G3: Sb2 + Filtek-Flow Z350 (Sb2Fl), G4: Scotchbond-Multipurpose (SBMP), G5: Clearfil-S3 (CS3), G6: CS3 + Bond/Clearfil-SE Bond (CSE3B), G7: CS3 + Protect Liner F (CS3PL) and G8: Clearfil SE Bond + Protect Liner F (CSEBPL). The same combinations were applied to the cavities in CM: G9, G10, G11, G12, G13, G14, G15, G16, respectively. The fillings were performed with the Sinfony-System (3M/ESPE). After 24 h, the teeth were submitted to thermocycling (2,000 cycles, 5° to 55°C) and load-cycling (50,000 cycles, 50 N). Next, the Caries-Detector (Kuraray) was applied to the restoration margins. Images from the proximal margin were evaluated using the Image-Tool 3.0 software. The results were submitted to ANOVA and Tukey's test (α=0.05). The mean values (%) for the groups were: EM: G1=46.68, G2=15.53, G3=19.83, G4=27.53; G5=59.49, G6=25.13, G7=34.37, G8=15.20; CM: G9=38.38, G10=23.25, G11=26.97, G12=25.85, G13=37.81, G14=30.62, G15=29.17, G16=20.31. The highest percentages of marginal gap on EM or CM were found in the groups that did not use a liner. It can be concluded that the most appropriate RCT combinations were the groups that used a liner.

Este estudo avaliou a influência de diferentes combinações de materiais usados na técnica de selamento dentinário (TSD) sobre a adaptação marginal de restaurações indiretas, cujas margens gengivais localizam-se em esmalte (ME) ou cemento (MC). Oitenta terceiros molares foram selecionados e duas cavidades foram preparadas em cada dente, as quais foram distribuídas em 16 grupos. As cavidades com margem em esmalte foram forradas pelas seguintes combinações de materiais: G1: Single-Bond2 (Sb2), G2: Sb2 + Bond/Scotchbond-Multipurpose (Sb2B), G3: Sb2 + Filtek-Flow Z350 (Sb2Fl), G4: Scotchbond-Multipurpose (SBMP), G5: Clearfil-S3 (CS3), G6: CS3 + Bond/Clearfil-SE Bond (CSE3B), G7: CS3 + Protect Liner F (CS3PL), G8: Clearfil SE Bond + Protect Liner F (CSEBPL). As mesmas combinações foram aplicadas às cavidades com margens em cemento: G9, G10, G11, G12, G13, G14, G15, G16, respectivamente. As restaurações foram confeccionadas usando o sistema Sinfony (3M/ESPE). Após 24 h, os dentes restaurados foram submetidos à ciclagem térmica (2.000 ciclos - 5° a 55° C) e mecânica (50.000 ciclos, 50 N). Em seguida, Carie-Detector (Kuraray) foi aplicado sobre as margens das restaurações. As imagens obtidas da margem proximal foram avaliadas pelo software Image-Tool 3.0. Os resultados foram submetidos aos testes estatísticos ANOVA e Tukey (p<0,05). As médias (%) observadas para os grupos foram: ME: G1=46,68, G2=15,53, G3=19,83, G4=27,53; G5=59,49, G6=25,13, G7=34,37 e G8=15,20; MC: G9=38,38, G10=23,25, G11=26,97, G12=25,85, G13=37,81, G14=30,62, G15=29,17, G16=20,31. Os maiores valores de desadaptação marginal encontrados em ME e MC foram encontrados nos grupos que não utilizaram um "liner". Desta forma, pôde-se concluir que a combinação mais apropriada para a TSD é aquela que faz uso do "liner".
Descritores: Resinas Compostas/química
Adaptação Marginal Dentária
Forramento da Cavidade Dentária/métodos
Materiais Dentários/química
Restauração Dentária Permanente/classificação
-Ataque Ácido Dentário/métodos
Bis-Fenol A-Glicidil Metacrilato/química
Preparo da Cavidade Dentária/classificação
Cimentos Dentários/química
Cemento Dentário/ultraestrutura
Esmalte Dentário/ultraestrutura
Adesivos Dentinários/química
Corantes Fluorescentes
Teste de Materiais
Polietilenoglicóis/química
Ácidos Polimetacrílicos/química
Cimentos de Resina/química
Rodaminas
Estresse Mecânico
Propriedades de Superfície
Silanos/química
Temperatura Ambiente
Fatores de Tempo
Limites: Seres Humanos
Tipo de Publ: Estudo Comparativo
Ensaio Clínico Controlado Aleatório
Research Support, Non-U.S. Gov't
Responsável: BR1.1 - BIREME


  9 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-650622
Autor: Mollica, Fernanda Brandão; Torres, Carlos Rocha Gomes; Gonçalves, Sergio Eduardo de Paiva; Mancini, Maria Nadir Gasparoto.
Título: Dentine microhardness after different methods for detection and removal of carious dentine tissue
Fonte: J. appl. oral sci;20(4):449-454, July-Aug. 2012. ilus, tab.
Idioma: en.
Resumo: There are several methods for identifying carious dentinal tissue aiming to avoid removal of healthy dentinal tissue. OBJECTIVES: The purpose of this study was to test different methods for the detection of carious dentinal tissue regarding the amount of carious tissue removed and the remaining dentin microhardness after caries removal. MATERIAL AND METHODS: The dentin surfaces of 20 bovine teeth were exposed and half of the surface was protected with nail polish. Cariogenic challenge was performed by immersion in a demineralizing solution for 14 days. After transverse cross-section of the crown, the specimens were divided into four groups (n=10), according to the method used to identify and remove the carious tissue: "Papacárie", Caries-detector dye, DIAGNOdent and Tactile method. After caries removal, the cross-sectional surface was included in acrylic resin and polished. In a microhardness tester, the removed dentin thickness and the Vickers microhardness of the following regions were evaluated: remaining dentin after caries removal and superficial and deep healthy dentin. RESULTS: ANOVA and Tukey's test (α=0.05) were performed, except for DIAGNOdent, which did not detect the presence of caries. Results for removed dentin thickness were: "Papacárie" (424.7±105.0; a), Caries-detector dye (370.5±78.3; ab), Tactile method (322.8±51.5; bc). Results for the remaining dentin microhardness were: "Papacárie" (42.2±10.5; bc), Caries-detector dye (44.6±11.8; abc), Tactile method (24.3±9.0; d). CONCLUSIONS: DIAGNOdent did not detect the presence of carious tissue; Tactile method and "Papacárie" resulted in the least and the most dentinal thickness removal, respectively; Tactile method differed significantly from "Papacárie" and Caries-detector dye in terms of the remaining dentin microhardness, and Tactile method was the one which presented the lowest microhardness values.
Descritores: Cárie Dentária/diagnóstico
Cárie Dentária/terapia
Dentina/química
-Análise de Variância
Dentina/efeitos dos fármacos
Fluorescência
Testes de Dureza
Papaína
Propilenoglicóis
Reprodutibilidade dos Testes
Rodaminas
Propriedades de Superfície
Limites: Animais
Bovinos
Responsável: BR1.1 - BIREME


  10 / 30 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo
Texto completo
Id: lil-644882
Autor: Miyaki, Liza Aya Mabuchi; Sibov, Tatiana Tais; Pavon, Lorena Favaro; Mamani, Javier Bustamante; Gamarra, Lionel Fernel.
Título: Study of internalization and viability of multimodal nanoparticles for labeling of human umbilical cord mesenchymal stem cells / Estudo de internalização e viabilidade de nanopartículas multimodal para marcação de células-tronco mesenquimais de cordão umbilical humano
Fonte: Einstein (Säo Paulo);10(2), apr.-jun. 2012. ilus, graf.
Idioma: en; pt.
Resumo: Objective: To analyze multimodal magnetic nanoparticles-Rhodamine B in culture media for cell labeling, and to establish a study of multimodal magnetic nanoparticles-Rhodamine B detection at labeled cells evaluating they viability at concentrations of 10mug Fe/mL and 100mug Fe/mL. Methods: We performed the analysis of stability of multimodal magnetic nanoparticles-Rhodamine B in different culture media; the mesenchymal stem cells labeling with multimodal magnetic nanoparticles-Rhodamine B; the intracellular detection of multimodal magnetic nanoparticles-Rhodamine B in mesenchymal stem cells, and assessment of the viability of labeled cells by kinetic proliferation. Results: The stability analysis showed that multimodal magnetic nanoparticles-Rhodamine B had good stability in cultured Dulbecco's Modified Eagle's-Low Glucose medium and RPMI 1640 medium. The mesenchymal stem cell with multimodal magnetic nanoparticles-Rhodamine B described location of intracellular nanoparticles, which were shown as blue granules co-localized in fluorescent clusters, thus characterizing magnetic and fluorescent properties of multimodal magnetic nanoparticles-Rhodamine B. Conclusion: The stability of multimodal magnetic nanoparticles-Rhodamine B found in cultured Dulbecco's Modified Eagle's-Low Glucose medium and RPMI 1640 medium assured intracellular mesenchymal stem cells labeling. This cell labeling did not affect viability of labeled mesenchymal stem cells since they continued to proliferate for five days.

Objetivo: Analisar a estabilidade das nanopartículas magnéticas multimodais-Rhodamine B em meios de cultura para marcação celular e, consequentemente, estabelecer o estudo de detecção intracelular de nanopartículas magnéticas multimodais-Rhodamine B nas células marcadas, avaliando a viabilidade celular nas concentrações de 10mig Fe/mL e 100mig Fe/mL. Métodos: Foram realizados: análise da estabilidade das nanopartículas magnéticas multimodais-Rhodamine B em meios de cultura diferentes; marcação das células-tronco mesenquimais com nanopartículas magnéticas multimodais-Rhodamine B; detecção intracelular das nanopartículas magnéticas multimodais-Rhodamine B nas células-tronco mesenquimais e avaliação da viabilidade das células marcadas por meio da cinética de proliferação. Resultados: A análise de estabilidade determinou que as nanopartículas magnéticas multimodais-Rhodamine B presentes nos meios de cultura Dulbecco's Modified Eagle's-Low Glucose e RPMI Medium 1640 apresentaram boa estabilidade. A marcação das células-tronco mesenquimais com nanopartículas magnéticas multimodais-Rhodamine B descreveu localização intracelular das nanopartículas, as quais se mostraram como grânulos azulados colocalizados nos grumos fluorescentes, caracterizando, assim, as propriedades magnéticas e fluorescentes das nanopartículas magnéticas multimodais-Rhodamine B. Conclusão: A estabilidade das nanopartículas magnéticas multimodais-Rhodamine B, presentes nos meios de cultura Dulbecco's Modified Eagle's-Low Glucose e RPMI Medium 1640, garantiu a eficiente marcação intracelular das células-tronco mesenquimais. Esse tipo de marcação não afetou viabilidade das células-tronco mesenquimais marcadas, já que as mesmas continuaram proliferando ao longo de 5 dias.
Descritores: Células Mesenquimais Estromais
Nanopartículas
Rodaminas
Responsável: BR500.1 - Biblioteca



página 1 de 3 ir para página          
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde