Base de dados : LILACS
Pesquisa : D05.750.078.625 [Categoria DeCS]
Referências encontradas : 163 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 17 ir para página                         

  1 / 163 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-1145353
Autor: Ñaupari-Villasante, Romina; Cuadros-Sanchez, Johanna; Tay, Lidia Yileng.
Título: Effect of the manual manipulation of composite resin with latex gloves / Efecto de la manipulación manual de resina compuesta con guantes de látex
Fonte: J. oral res. (Impresa);8(4):310-315, nov. 5, 2019. tab.
Idioma: en.
Resumo: Purpose: This in vitro study aimed to evaluate the influence of the manual manipulation of two composite resins: Filtek™ Z350XT (3M ESPE) and Herculite Précis® (Kerr), with latex gloves contaminated with powder, human saliva and alcohol, on the microhardness values. Material and Methods: Manual manipulation was evaluated using latex gloves with powder, latex gloves without powder, latex gloves without powder with saliva, latex gloves without powder with alcohol, and without hand manipulation or contaminants (control). Each resin was manually manipulated for 10 seconds and photoactivated for 20 seconds with a light intensity of 1000mW/cm2 using a VALO ­Ultradent LED light­ cured unit, and then each sample was evaluated on the microhardness Vickers tester Leitz (Wetzlar). The collected data were analyzed using Kruskal ­Wallis and Mann ­ Whitney post-test (p<0.05). Results. Microhardness values showed a significant difference between the evaluated and control groups, showing lower microhardness values in the group of latex glove with powder for Filtek™ Z350XT and the group of latex glove without powder with saliva for Herculite Précis®. Conclusion. The manual manipulation of composite resins decreases their surface microhardness.

Propósito: Este estudio in vitrotuvo como objetivo evaluar la influencia de la manipulación manual de dos resinas compuestas: Filtek ™ Z350XT (3M ESPE) y Herculite Précis® (Kerr), con guantes de látex contaminados con polvo, saliva humana y alcohol, sobre los valores de microdureza. Material y Métodos: La manipulación manual se evaluó utilizando guantes de látex con polvo, guantes de látex sin polvo, guantes de látex sin polvo con saliva, guantes de látex sin polvo con alcohol, y sin manipulación manual o contaminantes (control). Cada resina fue manipulada manualmente durante 10 segundos y fotoactivada durante 20 segundos con unaintensidad de luz de 1000mW/cm2 usando una unidad de fotocuración LED VALO - Ultradent, y luego cada muestra fue evaluada en el tester de microdureza Vickers Leitz (Wetzlar). Los datos recopilados se analizaron utilizando Kruska ­Wallis y post-test Mann­ Whitney (p<0.05). Resultados: Se observó una diferencia significativa en los valores de microdureza entre los grupos evaluados y el grupo control, con valores más bajos de microdureza en el grupo de guantes de látex con polvo para Filtek™ Z350XT y el grupo de guantes de látex sin polvo con saliva para Herculite Précis®. Conclusión. La manipulación manual de resinas compuestas disminuye su microdureza superficial.
Descritores: Resinas Compostas
Materiais Dentários/efeitos adversos
Luvas Cirúrgicas
Testes de Dureza
-Permeabilidade
Técnicas In Vitro
Contaminantes Físicos/efeitos adversos
Poluentes Ambientais/efeitos adversos
Látex/química
Limites: Humanos
Responsável: CL30.1 - Biblioteca


  2 / 163 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-950431
Autor: Pinho, Erika Christina Canarim Martha de; Chahud, Fernando; Lachat, João-José; Coutinho-Netto, Joaquim José; Sousa, Sidney Julio Faria e.
Título: The study of the use of a latex biomembrane and conjunctival autograft in rabbit conjunctiva wound healing / Estudo do implante de biomembrana de látex e auto-enxerto conjuntival em cicatrização de ferida conjuntiva de coelho
Fonte: Arq. bras. oftalmol;81(2):125-129, Mar.-Apr. 2018. tab, graf.
Idioma: en.
Resumo: RESUMO Objetivo: Estudar o uso da biomembrana de látex e o transplante conjuntival autólogo na cicatrização conjuntival em coelhos. Métodos: Em nove coelhos albinos, neo-zelandeses, machos foram removidas áreas retangulares idênticas, do quadrante supero nasal, adjacente ao limbo, de ambos os olhos. As áreas desnudas da camada esclerótica nos olhos direitos foram recobertas com biomembrana de látex e a dos olhos esquerdos com enxerto conjuntival autólogo. Os animais foram sacrificados em grupos de três, aos 7, 14 e 21 dias após a cirurgia. Os tecidos do local cirúrgico, incluindo a córnea, foram fixados em formaldeído, antes de serem processados em parafina e corados com hematoxilina e eosina. A natureza e a intensidade da resposta inflamatória e o padrão de epitelização da superfície conjuntival foram avaliados sob microscopia óptica, em seções histológicas longitudinais, passando pelo centro dos espécimes anatômicos. Resultados: Até o décimo quarto dia pós-operatório, o grupo que recebeu a biomembrana apresentou reação inflamatória mais intensa do que o grupo com auto enxerto conjuntival. Aos 14 dias, os olhos com biomembrana apresentavam-se menos inflamados e com estroma mais espesso do que aos 7 dias. Aos 21 dias, a reparação conjuntival de ambos os grupos apresentavam características semelhantes. Conclusão: Apesar de apresentar uma cicatrização mais lenta, a biomembrana de látex se mostrou tão eficaz quanto o auto enxerto conjuntival na reconstrução da superfície ocular após três semanas de cicatrização pós-operatória. Devido as suas baixas toxicidade e alergenicidade, este material parece ser uma opção terapêutica promissora na reconstrução da conjuntiva.

ABSTRACT Purpose: To study a latex biomembrane and conjunctival autograft with regard to the promotion of conjunctival healing in rabbits. Methods: The study included nine male albino rabbits. In these rabbits, a rectangular area of the conjunctiva was surgically removed from the superonasal quadrant adjacent to the limbus in both eyes. The bare area of the sclerotic coat of the right eye was reconstructed with a latex biomembrane, and the corresponding site of the left eye was reconstructed with a conjunctival autograft. The animals were killed in groups of three at 7, 14, and 21 days after surgery. The tissues from the surgical site, including the cornea, were fixed in formaldehyde, and were then processed in paraffin and stained with hematoxylin and eosin. The nature and intensity of the inflammatory response and the epithelial pattern at the conjunctival surface were evaluated under optical microscopy with longitudinal histological sections through the center of the anatomical specimens. Results: Until the 14th postoperative day, the inflammatory reaction was greater in the biomembrane group than in the conjunctival autograft group. In the latex biomembrane group, inflammation was less intense and the stroma was thicker on the 14th postoperative day than on the 7th postoperative day. After three weeks, conjunctival healing in both groups showed similar characteristics. Conclusion: Although healing was slower with a latex biomembrane, tissue reconstitution was almost the same as that with a conjunctival autograft by three weeks. A latex biomembrane is as effective as a conjunctival autograft for the reconstruction of the ocular surface. Owing to the lack of toxicity and allergenicity, a latex biomembrane appears to be a promising therapeutic option for conjunctival reconstruction.
Descritores: Cicatrização/fisiologia
Túnica Conjuntiva/transplante
Autoenxertos/fisiologia
Látex/uso terapêutico
Membranas Artificiais
-Fatores de Tempo
Índice de Gravidade de Doença
Teste de Materiais
Reprodutibilidade dos Testes
Resultado do Tratamento
Túnica Conjuntiva/patologia
Limites: Animais
Ratos
Tipo de Publ: Estudo de Avaliação
Responsável: BR1.1 - BIREME


  3 / 163 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-614377
Autor: Arruda, Priscila Campos de; Matta, Edgard Norães Rodrigues da; Silva, Silvio Chagas da.
Título: Influência do grau de ativação na deformação plástica de elasticos ortodônticos em cadeia / Influence of the degree of activation on the plastic deformation of orthodontic elastic chain
Fonte: Pesqui. bras. odontopediatria clín. integr;11(01):85-90, jul. 2011.
Idioma: pt.
Resumo: Objetivo: Avaliar a influência do grau de ativação na deformação plástica de elásticos ortodônticos em cadeia em função do tempo que permaneceram estirados. Método: Foram testadas 72 amostras de cadeia elástica da marca Morelli, tamanho médio cristal, que foram mantidas em um jig confeccionado, especialmente, para este fim, com diferentes graus de ativação, 30%, 50% e 70% dos seus comprimentos iniciais, sendo avaliadas 24 cadeias elásticas para cada grau de ativação. Os elásticos foram mantidos em suas embalagens plásticas originais, como recomendado pelo fabricante, até serem testados. O jig com os elásticos foram conservados em um recipiente plástico contendo saliva artificial e mantidos em uma estufa artesanal com temperatura controlada de 37ºC ± 1ºC por todo o tempo do experimento, sendo removidos deste ambiente somente ao final de 3 semanas de ativação. As medidas dos comprimentos iniciais e finais de seis elos de cada cadeia elástica foram realizadas utilizando-se um paquímetro digital de precisão e o percentual de deformação plástica foi calculado em relação ao comprimento inicial. A comparação entre os valores médios de deformação plástica sofrida pelos elásticos nos diferentes graus de ativação foi realizada estatisticamente com o auxílio do programa SPSS (Statistical Package for Social Sciences), versão 15.0. Resultados: Os valores médios encontrados, 13,89%, 20,66% e 30,68% de deformação plástica, para os diferentes graus de ativação, respectivamente, foram submetidos a teste estatístico análise de variância (ANOVA) com nível de significância de 5%, tendo sido encontrada significância estatística entre os mesmos. Conclusão: O grau de ativação influenciou de forma significativa a deformação plástica sofrida pelos elásticos testados.

Objective: To evaluate the influence of the degree of activation on the plastic deformation of orthodontic elastic chains according to the stretching duration. Methods: Seventy-two samples of medium size crystal orthodontic elastic chains from the commercial brand Morelli were maintained in a custom-made jig with different degrees of activation (30%, 50% and 70%) of their initial lengths, being 24 elastic chains for each degree of activation. The elastics were maintained in their original plastic packages, as recommended by the manufacturer, until the moment of testing. The jig with the elastics were kept in a plastic recipient containing artificial saliva and stored in an artisanal stove with controlled temperature of 37§C ñ 1§C during the whole experiment, being removed only after 3 weeks of activation. The initial and final lengths of 6 rings of each elastic chain were measured using a precision digital caliper and the percentage of plastic deformation in relation to the initial length was calculated. Comparison among the mean values of plastic deformation suffered by the elastics with the different degrees of activation was performed using the SPSS (Statistical Package for Social Sciences) software, version 15.0. Data were analyzed statistically by ANOVA with significance level of 5%. Results: The mean values of plastic deformation for the 30%, 50% and 70% degrees of activation were 13.89%, 20.66% and 30.68%, respectively, with statistically significant difference (p<0.05) among them. Conclusion: The degree of activation influenced significantly the plastic deformation suffered by the elastics evaluated in this study.
Descritores: Aparelhos Ortodônticos
Elastômeros
Látex/análise
Teste de Materiais
Responsável: BR1.1 - BIREME


  4 / 163 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-1057962
Autor: Felipetti, Francielly Andressa; Bereta, Rafaela Mariano; Piedade, Sônia Maria Stefano; Novaes, Pedro Duarte.
Título: Oral Administrations of Hancornia speciosa Gomes Latex Do Not Increase Bone Neoformation / Administrações Orais do Látex da Hancornia speciosa Gomes não aumentam a neoformação óssea
Fonte: Rev. bras. ortop;54(6):692-696, Nov.-Dec. 2019. graf.
Idioma: en.
Resumo: Abstract Objective The present work aimed to evaluate the systemic effect of H. speciosa latex on bone neoformation. Methods For this, the latex was collected and diluted to 3% and 50%. A total of 28 Wistar rats were submitted to surgery to create a 5 mm diameter defect in the parietal bone. This experiment was conducted in 2 different periods: 1 and 2. For each period, the rats were divided into 3 groups: Control Group, Latex3 Group, and Latex50 Group, which received, respectively, daily administrations of 0.5 mL of distilled water, latex to 3% and latex to 50% by gavage, orally. The rats of periods 1 and 2 were euthanized, respectively, 15 and 30 days after the surgery, and the calvaria was collected. The results were analyzed using the ANOVA and Tukey tests; the significance level was 0.05. Results We show that, in each analyzed period, the experimental groups had the same amount of newly formed bone in the calvaria defect. Conclusion We conclude that daily and oral administrations of H. speciosa latex to 3% and to 50% over a period of 15 and 30 days does not contribute to the increase of the area of the newly formed bone in the calvaria defect.

Resumo Objetivo Este trabalho objetivou avaliar o efeito sistêmico do látex de H. speciosas obre a neoformação óssea. Métodos Para isso, o látex foi coletado e diluído a 3% e a 50%. Um total de 28 ratos Wistar foi submetido a cirurgia para a criação de um defeito de 5 mm de diâmetro no osso parietal. Esse experimento foi conduzido em dois períodos distintos: 1 e 2. Para cada período, os ratos foram divididos em 3 grupos: Grupo Controle, Grupo Látex3 e Grupo Látex50 que receberam, respectivamente, administrações diárias de 0,5 mL de água destilada, látex a 3% e látex a 50% por gavagem, via oral. Os ratos dos períodos 1 e 2 foram eutanasiados, respectivamente, 15 e 30 dias após a cirurgia e a calvária foi coletada. Os resultados foram analisados utilizando os testes ANOVA e Tukey; o nível de significância estabelecido foi 0,05. Resultados Mostramos que, em cada período analisado, os grupos experimentais tiveram a mesma quantidade de osso neoformado no defeito da calvária. Conclusão Portanto, concluímos que administrações diárias e orais do látex de H. speciosa a 3% e a 50% durante um período de 15 e 30 dias não contribui para o aumento da área do osso neoformado no defeito da calvária.
Descritores: Osso e Ossos
Terapias Complementares
Administração Oral
Apocynaceae
Hematoxilina
Histologia
Látex
Limites: Animais
Ratos
Responsável: BR26.1 - Biblioteca Central


  5 / 163 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-555566
Autor: Mesquita, Alessandro Carlos; Oliveira, Luiz Edson Mota de.
Título: Caracteristicas anatômicas da casca e produção de látex em plantas de seringueira não enxertadas / Anatomic bark characteristics and latex production in non-grafted rubber trees
Fonte: Acta amaz;40(2):241-246, 2010. ilus, tab.
Idioma: pt.
Resumo: As estruturas envolvidas na produção de látex na seringueira são os laticíferos articulados. O objetivo deste estudo foi descrever aspectos anatômicos da casca em seringueiras não enxertadas com quatro, seis e oito anos, visando à seleção de materiais promissores. O material analisado foi obtido através do corte da casca à altura aproximada de 1,50 m do solo, chegando até o xilema da planta. Os cortes transversais foram preparados de acordo com as técnicas usuais de microtécnica vegetal. Os resultados permitem concluir, que a utilização de caracteres anatômicos (diâmetro das células), da espessura da casca e do diâmetro do caule, visando à seleção dos materiais de pés-francos com idades diferentes, apresentaram uma correlação significativa com a produção de látex.

The structures involved in latex production in rubber trees are articulated laticifers. The objective of this study was to describe anatomical aspects of the bark in four, six and eight year old non-grafted rubber plants, with the view of selecting materials of high yield potential. The analyzed material was obtained from bark cut around 1.50 m from the soil up to the xylem of the plant. The transversal cuts were prepared according to standard plant microtechniques. Based on the results, we can conclude that the use of anatomical characteristics (cell diameter), bark thickness and shoot diameter for selecting material from rootstocks plus non-grafted plants of different ages, showed a significant correlation with latex production.
Descritores: Hevea
Produção de Produtos
Anatomia
Látex
Responsável: BR6.1 - BCS - Biblioteca de Ciências da Saúde


  6 / 163 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-977930
Autor: Wanderley, Ledia Feitosa; Soares, Alexandra Martins dos Santos; Silva, Carolina Rocha e; Figueiredo, Isaias Moreira de; Ferreira, Andre Teixeira da Silva; Perales, Jonas; Mota, Handerson Ribeiro de Oliveira; Oliveira, Jose Tadeu Abreu; Costa Junior, Livio Martins.
Título: A cysteine protease from the latex of Ficus benjamina has in vitro anthelmintic activity against Haemonchus contortus / Atividade anti-helmíntica in vitro de uma protease cisteínica do látex de Ficus benjamina contra Haemonchus contortus
Fonte: Rev. bras. parasitol. vet;27(4):473-480, Oct.-Dec. 2018. tab, graf.
Idioma: en.
Resumo: Abstract Haemonchus contortus is a gastrointestinal nematode that is responsible for high mortality rates in ruminant herds. The resistance of nematodes to synthetic anthelmintics is widespread and requires a continuous search for new bioactive molecules, such as proteins. The objective of this study was to evaluate the anthelmintic potential of a protease purified from the latex of Ficus benjamina against H. contortus . Fresh latex was collected from plants via small incisions in the green stems, the rubber was removed by centrifugation, and the latex protein extract (LPE) was obtained. After LPE fractionation with ammonium sulfate and chromatography of the fraction containing the highest proteolytic activity on CM-cellulose, a cysteine protease (FbP) was purified. FbP has a molecular mass of approximately 23.97 kDa, and its proteolytic activity was stable between pH 6.0 and pH 10 and over a broad temperature range, with optimum activity at 60 °C. FbP inhibited both the development and exsheathment of H. contortus larvae, with 50% effective concentrations of 0.26 and 0.79 mg/mL, respectively. We conclude that this cysteine protease from F. benjamina latex with anthelmintic activity against H. contortus could be a promising alternative for the development of products for use in parasite control programmes.

Resumo Haemonchus contortus é um nematoide gastrintestinal, responsável por altas taxas de mortalidade em rebanhos de pequenos ruminantes. A resistência dos nematoides aos anti-helmínticos sintéticos está generalizada e requer uma busca contínua por novos compostos bioativos, como as proteínas. O objetivo deste trabalho foi avaliar o potencial anti-helmíntico da protease purificada do látex de Ficus benjamina contra H. contortus . O látex fresco foi coletado das plantas por pequenas incisões nas hastes verdes e o extrato proteico de látex (EPL) foi obtido. Após o fracionamento do EPL com sulfato de amônio e cromatografia da fração contendo a maior atividade proteolítica da CM-Celulose, uma protease cisteínica (FbP) foi purificada. A FbP tem massa molecular de cerca de 23,97 kDa, a atividade proteolítica foi estável entre pH 6,0 e pH 10 e ao longo de uma ampla faixa de temperatura, com atividade ótima a 60 °C. A FbP inibiu tanto o desenvolvimento quanto o desembainhamento das larvas de H. contortus, com 50% de inibição nas concentrações de 0,26 e 0,79 mg/mL, respectivamente. Concluímos que esta protease cisteínica do látex de F. benjamina, com ação anti-helmíntica contra H. contortus, pode ser uma alternativa promissora para o desenvolvimento de produtos a serem utilizados em programas de controle de parasitos.
Descritores: Extratos Vegetais/farmacologia
Ficus/química
Cisteína Proteases/farmacologia
Haemonchus/efeitos dos fármacos
Látex/química
Anti-Helmínticos/farmacologia
-Ovinos/parasitologia
Testes de Sensibilidade Parasitária
Eletroforese em Gel de Poliacrilamida
Cisteína Proteases/isolamento & purificação
Limites: Animais
Responsável: BR1.1 - BIREME


  7 / 163 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-289668
Autor: Lavado O., Violeta; Manrique Guzmán, Jorge.
Título: Permeabilidad mediante conductividad eléctrica en guantes de examen de látex / Permeability by means of electrical conductivity in gloves of examination of látex
Fonte: Rev. estomatol. Hered;10(1/2):11-6, 2000. ilus, tab.
Idioma: es.
Resumo: El presente estudio fue diseñado para evaluar, mediante la prueba de conductividad eléctrica, la permeabilidad de guantes de examen de látex de tres marcas comúnmente utilizadas por los odontológos de nuestro medio. La prueba consiste en un circuito eléctrico que funciona con una batería de 18,84 voltios, donde el guante se comporta como aislante eléctrico entre dos electrodos; si hay permeabilidad en el guante, el circuito eléctrico se cierra. Se realizaron pruebas piloto tomando un condón como patrón (látex natural), el cual no mostró permeabilidad eléctrica mayor de cero voltios. La muestra consistió en diez guantes de examen de látex nuevos de las marcas Cramberry, Ambiderm y Comfit, escogidos al azar de una caja nueva intercalado de cada marca hasta completar la muestra. Antes y después de la prueba se midió el grosor de cada guante a nivel de la zona de la palma de la mano con un micrómetro. Los guantes Confit presentaron la mayor permeabilidad (promedio 18.76 V), seguidos por los guantes Granberry (promedio 16.53 V). Los guantes Ambiderm presentaron la menor permeabilidad (promedio 0.20 V9, siendo, además, los más gruesos.
Descritores: Permeabilidade
Luvas Protetoras
Látex
Condutividade Elétrica
Responsável: PE1.1 - Oficina Universitária de Biblioteca


  8 / 163 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-564595
Autor: Sanvodal, Miguel; Ayala, Salomón; Oré, Raquel; Loli, Rudi; Huamán, Oscar.
Título: Estimulación de la actividad péptica del jugo gástrico, inducida por látex de Croton palanostigma (sangre de grado) / Croton palanostigma (cangre de grado) latex-induced gastric juice peptic activity stimulation
Fonte: An. Fac. Med. (Perú);69(3):164-167, jul.-sept. 2008. ilus, tab.
Idioma: es.
Resumo: Objetivo: Determinar si la administración del látex de Croton palanostigma (sangre de grado), vía digestiva, modifica la actividad péptica de la secreción gástrica. Diseño: Estudio experimental. Institución: Centro de Investigaciónde Bioquímica y Nutrición Alberto Guzmán Barrón, Facultad de Medicina, Universidad Nacional Mayor de San Marcos. Material biológico: Ratas albinas machos adultos y sangre de grado. Métodos: Se usó 50 ratas albinas machos adultos, entre 200 y 250 g de peso, que fueron distribuidas aleatoriamente en 5 grupos, a los que se administró por vía oro-gástrica, y en dosis única, como sigue: grupo I: 0,8 mL/kg de sangre de grado; grupo II: 0,8 mL/kg de sangre de grado neutralizada; grupo III: ranitidina 50 mg/kg; grupo IV: control, con solución salina 0,9 g % (sin histamina); grupo V: control con solución salina 0,9 g %. Se realizó ligadura pilórica, por laparotomía, con anestesia de éter etílico. Se utilizó histamina, aplicada por vía subcutánea, para estimular la secreción, excepto al grupo IV. Cuatro horas después, se extrajo el jugo gástrico, se midió el volumen, el pH por potenciometría y la actividad de la pepsina, por el método de Anson modificado, expresado como ug de tirosina/mL. Principales medidas de resultados: Modificación de la actividad péptica de la secreción gástrica. Resultados: El volumen del jugo gástrico fue significativamente menor en los grupos II y III; que en los otros, entre los que no hubo diferencia estadística. El pH del grupo III (con ranitidina) fue significativamente mayor que los otros, demostrando el efecto del fármaco. La actividad péptica fue: con sangre de grado 5,34 mas 1,04; sangre de grado neutralizada 2,69 mas 1,27; grupo ranitidina 2,57 mas 0,88; el control sin histamina 3,29 mas 0,94 y control con histamina 3,58 mas 1,18. La actividad péptica fue significativamente mayor (mas 49,2%) en el grupo con sangre de grado (p < 0,01) que en los otros grupos.

Objective: To determine if Croton palanostigma (sangre de grado) oral administration modifies gastric secretion peptic activity. Design: Experimental study. Institution: Alberto Guzman Barron Biochemistry and Nutrition Research Center, Faculty of Medicine, Universidad Nacional Mayor de San Marcos. Biologic material: Adult male albino rats and sangre de grado. Methods: Fifty 200 to 250 g adult male albino rats were randomly distributed in 5 groups according to sangre de grado oro-gastric one dose administration: group I: 0,8 mL/kg of sangre de grado; group II: 0,8 mL/kg of neutralized sangre de grado; group III: ranitidine 50 mg/kg; group IV: control group with saline solution 0,9 g % (without histamine); group V: control group with saline solution 0,9 g %. Pyloric ligature by laparotomy was done under ethylic ether anesthesia. Subcutaneously applied histamine was used to stimulate secretion, except to group IV. Four hours later, gastric juice was extracted, volume was measured, pH was determined by potentiometry and pepsin activity by modified Anson method, measured as tirosine ug/mL. Main outcome measures: Gastric secretion peptic activity modification. Results: Gastric juice volume was significantly lower in groups II and III, with no statistic difference in the other groups. Group III pH (with ranitidine) was significantly higher, showing the medicine effect. Peptic activity was as follows: 5,34 more 1,04 with sangre de grado; 2,69 more 1,27 with neutralized sangre de grado; 2,57 more 0,88 the ranitidine group; 3,29 more 0,94 control group without histamine and 3,58 more 1,18 control group with histamine. Peptic activity was significantly higher (more 49,2 %) in the sangre de grado group (p < 0,01). Conclusions: There was gastic peptic activity following the oro-gastric administration of Croton palanostigma (sangre de grado), with no pH variation.
Descritores: Fármacos Gastrointestinais
Croton
Suco Gástrico
Látex
Pepsina A
-Epidemiologia Experimental
Limites: Animais
Responsável: PE1.1 - Oficina Universitária de Biblioteca


  9 / 163 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-295105
Autor: Conde-Salazar, Luis.
Título: Urticaria alérgica de contacto al latex (UACL) / Allergic urticaria by latex contact (AULC)
Fonte: Dermatol. peru;10(2):104-14, jul.-dic. 2000. tab.
Idioma: es.
Resumo: La urticaria alérgica de contacto al látex (UACL) es una entidad que en los últimos años ha adquirido gran importancia al afectar a gran número de personas y, en especial, a trabajadores sanitarios. Las manifestaciones clínicas son variables, desde lesiones cutáneas localizadas hasta una reacción anafiláctica e, incluso, la muerte. Las técnicas de diagnóstico son diversas, destacan la prueba de punción o puntura (prick test) que, además de su sencillez y escaso precio, es de sensibilidad alta y fundamental para el diagnóstico; otras pruebas son el RAST, determinación del IgE específica, IgE alimentos y frutas, liberación de histamina e Imunoblotting, pero estas últimas, por su precio y complejidad, son menos utilizadas. Los alergenos causantes de esta sensibilización son unas proteínas de peso molecular entre 14 y 24 kDa, destacando las Hev b 1-9, hevaamina, quitinasas, profilina, entre otras. La existencia de reacciones cruzadas a diversas frutas complica más el pronóstico de estos enfermos. Las medidas de prevención pasan por la desaparición del uso de objetos de látex por el personal sanitario y de profesiones con amplio uso de guantes de goma, ya que se piensa que es la causa principal de esta sensibilización.
Descritores: Urticária
Adesivos
Alimentos
Látex
Proteínas
Limites: Humanos
Masculino
Feminino
Adolescente
Adulto
Responsável: PE1.1 - Oficina Universitária de Biblioteca


  10 / 163 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-779032
Autor: Penhavel, Maria Vitória Carmo; Tavares, Victor Henrique; Carneiro, Fabiana Pirani; Sousa, João Batista de.
Título: Effect of Hevea brasiliensis latex sap gel on healing of acute skin wounds induced on the back of rats / Efeito do gel da seiva do látex da Hevea brasiliensis na cicatrização de lesões cutâneas agudas induzidas no dorso de ratos
Fonte: Rev. Col. Bras. Cir;43(1):48-53, Jan.-Feb. 2016. tab, graf.
Idioma: en.
Resumo: Objective : to evaluate the effect of topical delivery of latex cream-gel in acute cutaneous wounds induced on the back of rats. Methods : we subjected sixteen rats to dermo-epidermal excision of a round dorsal skin flap, with 2.5cm diameter. We divided the animals into two groups: Latex Group: application of cream-gel-based latex throughout the wound bed on postoperative days zero, three, six and nine; Control group: no treatment on the wound. Photographs of the lesions were taken on the procedure day and on the 6th and 14th postoperative days, for analyzing the area and the larger diameter of the wound. We carried out euthanasia of all animals on the 14th postoperative day, when we resected he dorsal skin and the underlying muscle layer supporting the wound for histopathological study. Results : there was no statistically significant difference in the percentage of wound closure, in the histopathological findings or in the reduction of the area and of the largest diameter of the wounds among the groups studied on the 14th postoperative day. Conclusion : according to the experimental conditions in which the study was conducted, latex cream-gel did not interfere in the healing of acute cutaneous wounds in rats.

Objetivo : avaliar o efeito da administração tópica do gel-creme de látex em feridas cutâneas agudas induzidas no dorso de ratos. Métodos : dezesseis ratos foram submetidos à excisão dermoepidérmica de retalho cutâneo dorsal, circular com 2,5cm de diâmetro. Os animais foram distribuídos em dois grupos, um experimental e outro controle: Grupo Látex- aplicação em todo o leito da ferida do látex em base gel-creme no período zero, no terceiro, no sexto e no nono dias pós-operatórios; Grupo Controle- sem nenhum tratamento sobre a ferida. Foram feitas fotografias das lesões no dia da operação, no sexto e no 14º dia pós-operatório, para análise de área e do maior diâmetro da ferida. Realizou-se a eutanásia de todos os animais no 14º dia pós-operatório. Ressecou-se a pele dorsal e o plano muscular subjacente contendo a ferida para estudo histopatológico. Resultados : não houve diferença estatisticamente significante no percentual de fechamento, nos achados histopatológicos ou na redução da área e do maior diâmetro das feridas, entre os grupos estudados no 14º dia pós-operatório. Conclusão : nas condições experimentais em que o estudo foi realizado, o gel-creme de látex não interferiu na cicatrização de feridas cutâneas agudas em ratos.
Descritores: Pele/lesões
Cicatrização/efeitos dos fármacos
Hevea
Látex/uso terapêutico
Fitoterapia
-Administração Tópica
Ratos Wistar
Géis
Limites: Animais
Ratos
Responsável: BR1.1 - BIREME



página 1 de 17 ir para página                         
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde