Base de dados : LILACS
Pesquisa : E01.370.350.515.402.250 [Categoria DeCS]
Referências encontradas : 29 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 3 ir para página          

  1 / 29 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-850681
Autor: Faria, Renata; Camargo, Fernanda Pelógia; Barbosa, Silvia Helena; Bottino, Marco Antonio; Takahashi, Fernando Eidi.
Título: Avaliação do calor gerado durante o preparo do tecido ósseo utilizando-se brocas de diferentes sistemas de implantes / Evaluation of the temperature rise during the preparation on bone tissue with differents implant drill systems
Fonte: Ciênc. odontol. bras;8(4):56-67, out.-dez. 2005. ilus, tab, graf.
Idioma: pt.
Resumo: Avaliou-se neste estudo, a temperatura gerada durante o preparo do tecido ósseo comparando-se brocas de três sistemas de implantes: Conexão, Nobel e 3i. As perfurações foram feitas em osso cortical de fêmur bovino, com brocas de 2,0 e 3,0mm de diâmetro, até a profundidade de 13mm, a uma velocidade de 1500 rpm com pressão intermitente de 2kg e sob constante irrigação de soro fisiológico 0,9% a temperatura ambiente (24 ±1o C). As amostras foram mantidas em água a 36±1o C durante as perfurações. As temperaturas foram medidas com termopares inseridos no osso a 1mm da perfuração, em profundidades de 5 e 13mm e registradas com o auxílio de um coletor de dados conectado a um computador. Os dados de temperatura foram analisados pelo teste RM ANOVA (3 fatores). A profundidade foi o fator repetido. As análises foram seguidas pelo teste de Tukey (5%). Os resultados indicaram que a melhor condição experimental foi obtida para a broca Conexão de diâmetro 2mm na profundidade de 5mm (36,10±0,52oC) e a condição menos favorável foi para a broca Nobel de diâmetro 2mm na profundidade de 13mm (38,84±1,15oC). Concluiu-se que os maiores valores de temperatura foram obtidos para a profundidade de 13mm, independentemente do tipo de broca. O aumento do diâmetro induziu uma diminuição da temperatura para as brocas 3i e Nobel e um aumento para as brocas Conexão. Nenhuma temperatura registrada excedeu o limite biológico.
Descritores: Calorimetria
Instrumentos Odontológicos
Temperatura Alta
Implantação Dentária Endo-Óssea/instrumentação
Osseointegração
-Implantes Dentários
Microanálise por Sonda Eletrônica
Microscopia Eletrônica de Varredura
Instrumentos Cirúrgicos
Limites: Animais
Bovinos
Tipo de Publ: Estudo Comparativo
Responsável: BR243.1 - Serviço Técnico de Biblioteca e Documentação


  2 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-709644
Autor: Gravina, Marco Abdo; Canavarro, Cristiane; Elias, Carlos Nelson; Chaves, Maria das Graças Afonso Miranda; Brunharo, Ione Helena Vieira Portella; Quintão, Cátia Cardoso Abdo.
Título: Mechanical properties of NiTi and CuNiTi wires used in orthodontic treatment. Part 2: Microscopic surface appraisal and metallurgical characteristics
Fonte: Dental press j. orthod. (Impr.);19(1):69-76, Jan-Feb/2014. tab, graf.
Idioma: en.
Resumo: OBJECTIVE: This research aimed at comparing the qualitative chemical compositions and the surface morphology of fracture regions of eight types of Nickel (Ni) Titanium (Ti) conventional wires, superelastic and heat-activated (GAC, TP, Ormco, Masel, Morelli and Unitek), to the wires with addition of copper (CuNiTi 27oC and 35oC, Ormco) after traction test. METHODS: The analyses were performed in a scanning electronic microscope (JEOL, model JSM-5800 LV) with EDS system of microanalysis (energy dispersive spectroscopy). RESULTS : The results showed that NiTi wires presented Ni and Ti as the main elements of the alloy with minimum differences in their composition. The CuNiTi wires, however, presented Ni and Ti with a significant percentage of copper (Cu). As for surface morphology, the wires that presented the lowest wire-surface roughness were the superelastic ones by Masel and Morelli, while those that presented the greatest wire-surface roughness were the CuNiTi 27oC and 35oC ones by Ormco, due to presence of microcavity formed as a result of pulling out some particles, possibly of NiTi. 4 The fracture surfaces presented characteristics of ductile fracture, with presence of microcavities. The superelastic wires by GAC and the CuNiTi 27oC and the heat-activated ones by Unitek presented the smallest microcavities and the lowest wire-surface roughness with regard to fracture, while the CuNiTi 35oC wires presented inadequate wire-surface roughness in the fracture region. CONCLUSION: CuNiTi 35oC wires did not present better morphologic characteristics in comparison to the other wires with regard to surfaces and fracture region. .

OBJETIVO: objetivou-se nessa pesquisa comparar as composições químicas qualitativas e as morfologias das superfícies e das regiões de fratura, após ensaios de tração, de oito tipos de fios de NiTi superelásticos e termoativados convencionais (GAC, TP, Ormco, Masel, Morelli e Unitek) aos fios com adição de cobre (CuNiTi 27°C e 35°C, da Ormco). MÉTODOS: as análises foram realizadas em microscópio eletrônico de varredura (JEOL, modelo JSM-5800 LV) com sistema de microanálise EDS (energy dispersive spectroscopy). RESULTADOS: os resultados mostraram que os fios de NiTi ensaiados apresentaram Ni e Ti como os principais elementos da liga, com diferenças mínimas em suas composições. Os fios de CuNiTi, por sua vez, apresentaram Ni e Ti, com percentual significativo de cobre (Cu). Em relação às morfologias das superfícies, os fios que apresentaram os melhores acabamentos foram os superelásticos da Masel e Morelli, e os que apresentaram os piores acabamentos foram os de CuNiTi 27°C e 35°C, da Ormco, graças à presença de microcavidades formadas devido ao arrancamento de partículas, possivelmente de NiTi 4 . As superfícies de fratura apresentaram características de fratura dúctil, com a presença de microcavidades. Os fios superelásticos da GAC e de CuNiTi 27°C, bem como os termoativados da Unitek, apresentaram as menores microcavidades e os melhores acabamentos à fratura, enquanto os fios de CuNiTi 35° apresentaram acabamentos inadequados das regiões de fratura. CONCLUSÃO: os fios de CuNiTi 35°C não apresentaram características morfológicas mais adequadas das superfícies e das regiões de fratura em relação aos demais fios. .
Descritores: Cobre/química
Ligas Dentárias/química
Níquel/química
Fios Ortodônticos
Titânio/química
-Corrosão
Elasticidade
Microanálise por Sonda Eletrônica
Temperatura Alta
Teste de Materiais
Fenômenos Mecânicos
Metalurgia
Microscopia Eletrônica de Varredura
Espectrometria por Raios X
Estresse Mecânico
Propriedades de Superfície
Limites: Humanos
Tipo de Publ: Estudo Comparativo
Responsável: BR1.1 - BIREME


  3 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-709635
Autor: Rocha, José Maurício da; Gravina, Marco Abdo; Campos, Marcio José da Silva; Quintão, Cátia Cardoso Abdo; Elias, Carlos Nelson; Vitral, Robert Willer Farinazzo.
Título: Shear bond resistance and enamel surface comparison after the bonding and debonding of ceramic and metallic brackets
Fonte: Dental press j. orthod. (Impr.);19(1):77-85, Jan-Feb/2014. tab, graf.
Idioma: en.
Resumo: OBJECTIVE: To evaluate, in vitro, the shear bond strength presented by three brands of polycrystalline ceramic brackets and one brand of metallic bracket; verify the adhesive remnant index (ARI) after the tests, and analyze, through scanning electron microscopy (SEM) the enamel surface topography after debonding, detecting the release of mineral particles. METHODS: Sixty bovine lower incisors were used. Three ceramic brackets (Allure(r), InVu(r), and Clarity(r)) and one metallic bracket (Geneus(r)) were bonded with Transbond XT(r). Kruskal-Wallis's test (significance level set at 5%) was applied to the results of share bond and ARI. Mann Whitney's test was performed to compare the pairs of brackets in relation to their ARI. Brown-Forsythe's test (significance level set at 5%) was applied to the results of enamel chemical composition. Comparisons between groups were made with Games-Howell's and the Post-hoc tests. RESULTS: No statistically significant difference was observed in relation to the shear bond strength loads. Clarity(r) brackets were the most affected in relation to the surface topography and to the release of mineral particles of enamel (calcium ions). CONCLUSION: With regard to the ARI, there was a prevalence of score 4 (40.4%). As for enamel surface topography, the Geneus(r) bracket was the only one which did not show superficial tissue loss. The InVu(r) and Clarity(r) ones showed cohesive fractures in 33.3% and the Allure(r) in 50%, the latter being the one that presented most fractures during removal. .

OBJETIVO: avaliar, in vitro, a resistência ao cisalhamento apresentada por três marcas de braquetes ortodônticos cerâmicos policristalinos e uma marca de braquete metálico, verificando os índices de resina remanescentes (IRA) após os ensaios, e analisar, por meio de microscopia eletrônica de varredura, as topografias superficiais do esmalte após a descolagem, detectando o desprendimento de partículas minerais desse. MÉTODOS: foram utilizados 60 incisivos inferiores bovinos. Os braquetes cerâmicos (Allure, InVu e Clarity) e metálico (Geneus) foram colados utilizando-se o adesivo Transbond XT. Para os resultados referentes ao cisalhamento e ao IRA, foi utilizado o teste de Kruskal-Wallis, com nível de significância de 5%. A prova de Mann-Whtiney foi utilizada para comparar os diferentes tipos de braquetes aos pares, quanto ao IRA. Para a análise dos resultados referentes às composições químicas do esmalte, aplicou-se o teste de Brown-Forsythe, com significância de 5%. As comparações entre os grupos foram realizadas utilizando os testes Post Hoc e de Games-Hoewell. RESULTADOS: não foram observadas diferenças significativas quanto às cargas de cisalhamento. O Clarity foi o mais afetado em relação à topografia e ao desprendimento de partículas minerais do esmalte (íons Ca). CONCLUSÃO: em relação ao IRA, foi confirmada a prevalência do escore 4, com um percentual de 40,4%. Em relação à topografia superficial do esmalte, o Geneus foi o único que não apresentou perda de tecido . O InVu e o Clarity apresentaram fraturas coesivas de 33,3% de suas amostras, e o Allure de 50%, sendo o que mais fraturou durante a remoção. .
Descritores: Cerâmica/química
Colagem Dentária
Ligas Dentárias/química
Esmalte Dentário/ultraestrutura
Materiais Dentários/química
Braquetes Ortodônticos
-Adesividade
Cálcio/análise
Esmalte Dentário/química
Análise do Estresse Dentário/instrumentação
Microanálise por Sonda Eletrônica
Falha de Equipamento
Teste de Materiais
Microscopia Eletrônica de Varredura
Desenho de Aparelho Ortodôntico
Cimentos de Resina/química
Resistência ao Cisalhamento
Espectrometria por Raios X
Estresse Mecânico
Propriedades de Superfície
Limites: Animais
Bovinos
Tipo de Publ: Estudo Comparativo
Responsável: BR1.1 - BIREME


  4 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-660357
Autor: Estrela, Carlos; Sousa-Neto, Manoel Damião; Guedes, Orlando Aguirre; Alencar, Ana Helena Gonçalves; Duarte, Marco Antonio Hungaro; Pécora, Jesus Djalma.
Título: Characterization of calcium oxide in root perforation sealer materials
Fonte: Braz. dent. j;23(5):539-546, Sept.-Oct. 2012. ilus, graf, tab.
Idioma: en.
Projeto: CNPq.
Resumo: Root perforation represents an undesirable complication that may lead to an unfavorable prognosis. The aims of this study were to characterize and to compare the presence of calcium oxide (CaO) on the chemical composition of materials used for root perforation therapy: gray and white mineral trioxide aggregate (MTA) and Portland cement (PC), gray MTA+5%CaO and gray MTA+10%CaO. The last two materials were analyzed to evaluate the increase of CaO in the final sample. CaO alone was used as a standard. Eighteen polyethylene tubes with an internal diameter of 3 mm and 3 mm in length were prepared, filled and then transferred to a chamber with 95% relative humidity and a temperature of 37ºC. The chemical compounds (particularly CaO) and the main components were analyzed by energy-dispersive X-ray microanalysis (EDX). EDX revealed the following concentrations of CaO: gray MTA: 59.28%, white MTA: 63.09%; PC: 72.51%; gray MTA+5%CaO: 63.48% and gray MTA+10%CaO: 67.55%. The tested materials presented different concentrations of CaO. Even with an increase of 5 and 10% CaO in gray MTA, the CaO levels found in the MTA samples were lower than those found in PC.

A perfuração do canal radicular representa uma complicação indesejável que sugere um prognóstico desfavorável. Os objetivos deste estudo foram caracterizar e comparar a presença de óxido de cálcio (CaO) na composição química de vários materiais utilizados no tratamento de perfurações radiculares. Foram analisados os materiais MTA cinza e branco, cimento Portland e na tentativa de se observar o aumento nos valores de CaO foram testados MTA cinza+5% de óxido de cálcio, MTA cinza+10% de óxido de cálcio e o CaO (padrão). Foram preparados 18 tubos de polietileno com diâmetro interno e comprimento de 3 mm. Estes foram preenchidos e depois transferidos para uma estufa com umidade relativa de 95% e temperatura de 37°C. Os compostos químicos (principalmente o óxido de cálcio) e os principais componentes foram avaliados por espectrometria de dispersão de raios-X (EDX). A análise por EDX revelou as seguintes concentrações de CaO: 59,28% no MTA cinza; 63,09% no MTA branco; 72,51% no cimento Portland; 63,48% no MTA cinza+5% de CaO; 67,55% no MTA cinza+10% de CaO. Os materiais testados apresentaram diferentes concentrações de CaO. Mesmo com o acréscimo de CaO nas concentrações de 5 e 10% ao MTA cinza, os valores de CaO foram inferiores aos observados no cimento Portland.
Descritores: Compostos de Alumínio/química
Compostos de Cálcio/química
Cimentos Dentários/química
Óxidos/química
Materiais Restauradores do Canal Radicular/química
Silicatos/química
-Combinação de Medicamentos
Microanálise por Sonda Eletrônica
Teste de Materiais
Microscopia Eletrônica de Varredura
Propriedades de Superfície
Tipo de Publ: Estudo Comparativo
Research Support, Non-U.S. Gov't
Responsável: BR1.1 - BIREME


  5 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-650627
Autor: Holst, Alexandra Ioana; Holst, Stefan; Hirschfelder, Ursula; Seckendorff, Volker Von.
Título: Retrieval analysis of different orthodontic brackets: the applicability of electron microprobe techniques for determining material heterogeneities and corrosive potential
Fonte: J. appl. oral sci;20(4):478-485, July-Aug. 2012. ilus.
Idioma: en.
Resumo: OBJECTIVE: The objective of this study was to investigate the applicability of micro-analytical methods with high spatial resolution to the characterization of the composition and corrosion behavior of two bracket systems. MATERIAL AND METHODS: The surfaces of six nickel-free brackets and six nickel-containing brackets were examined for signs of corrosion and qualitative surface analysis using an electron probe microanalyzer (EPMA), prior to bonding to patient's tooth surfaces and four months after clinical use. The surfaces were characterized qualitatively by secondary electron (SE) images and back scattered electron (BSE) images in both compositional and topographical mode. Qualitative and quantitative wavelength-dispersive analyses were performed for different elements, and by utilizing qualitative analysis the relative concentration of selected elements was mapped two-dimensionally. The absolute concentration of the elements was determined in specially prepared brackets by quantitative analysis using pure element standards for calibration and calculating correction-factors (ZAF). RESULTS: Clear differences were observed between the different bracket types. The nickel-containing stainless steel brackets consist of two separate pieces joined by a brazing alloy. Compositional analysis revealed two different alloy compositions, and reaction zones on both sides of the brazing alloy. The nickel-free bracket was a single piece with only slight variation in element concentration, but had a significantly rougher surface. After clinical use, no corrosive phenomena were detectable with the methods applied. Traces of intraoral wear at the contact areas between the bracket slot and the arch wire were verified. CONCLUSION: Electron probe microanalysis is a valuable tool for the characterization of element distribution and quantitative analysis for corrosion studies.
Descritores: Materiais Dentários/química
Microanálise por Sonda Eletrônica/métodos
Níquel/química
Braquetes Ortodônticos
Aço Inoxidável/química
-Corrosão
Teste de Materiais
Reprodutibilidade dos Testes
Propriedades de Superfície
Fatores de Tempo
Limites: Adolescente
Humanos
Responsável: BR1.1 - BIREME


  6 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Rosa, Adalberto Luiz
Texto completo
Id: lil-481122
Autor: Franco, Rosemeire de Lordo; Chiesa, Roberto; Oliveira, Paulo Tambasco de; Beloti, Marcio Mateus; Rosa, Adalberto Luiz.
Título: Bone response to a Ca- and P-enriched titanium surface obtained by anodization
Fonte: Braz. dent. j;19(1):15-20, 2008. ilus.
Idioma: en.
Projeto: FAPESP.
Resumo: This study evaluated bone response to a Ca- and P- enriched titanium (Ti) surface treated by a multiphase anodic spark deposition coating (BSP-AK). Two mongrel dogs received bilateral implantation of 3 Ti cylinders (4.1 x 12 mm) in the humerus, being either BSP-AK treated or untreated (machined - control). At 8 weeks postimplantation, bone fragments containing the implants were harvested and processed for histologic and histomorphometric analyses. Bone formation was observed in cortical area and towards the medullary canal associated to approximately 1/3 of implant extension. In most cases, in the medullary area, collagen fiber bundles were detected adjacent and oriented parallel to Ti surfaces. Such connective tissue formation exhibited focal areas of mineralized matrix lined by active osteoblasts. The mean percentages of bone-to-implant contact were 2.3 (0.0-7.2 range) for BSP-AK and 0.4 (0.0-1.3 range) for control. Although the Mann-Whitney test did not detect statistically significant differences between groups, these results indicate a trend of BSP-AK treated surfaces to support contact osteogenesis in an experimental model that produces low bone-to-implant contact values.

O objetivo desse estudo foi avaliar a resposta do tecido ósseo à superfície de titânio (Ti) enriquecida com Ca e P obtida por anodização (BSP-AK). Três cilindros de Ti (4,1 x 12 mm) BSP-AK ou usinado (controle) foram implantados bilateralmente nos úmeros de dois cães de raça indefinida. Oito semanas após a implantação, os fragmentos ósseos contendo os implantes foram removidos e processados para análises histológica e histomorfométrica. A formação óssea foi observada na região cortical e no canal medular até aproximadamente um terço da extensão do implante. Na maioria dos casos, feixes de fibras colágenas dispostos paralelamente à superfície do implante foram observados na região medular. Nessa região observaram-se também áreas focais de formação de matriz mineralizada e osteoblastos ativos. Os implantes do grupo BSP-AK apresentaram média de contato osso-implante 2,3 por cento, com medidas variando de 0,0 a 7,2 por cento e os do grupo controle tiveram média 0,4 por cento, com medidas variando de 0,0 a 1,3 por cento. Apesar do teste de Mann-Whitney não mostrar diferença estatisticamente significante entre os grupos, nossos resultados indicaram uma tendência para a ocorrência de osteogênese de contato na superfície BSP-AK em um modelo experimental que resulta em baixos valores de contato osso-implante.
Descritores: Cálcio/química
Materiais Revestidos Biocompatíveis/química
Implantes Dentários
Materiais Dentários/química
Galvanoplastia/métodos
Úmero/patologia
Fósforo/química
Titânio/química
-Medula Óssea/patologia
Remodelação Óssea/fisiologia
Colágeno
Tecido Conjuntivo/patologia
Planejamento de Prótese Dentária
Microanálise por Sonda Eletrônica
Úmero/cirurgia
Microscopia Eletrônica de Varredura
Modelos Animais
Osseointegração/fisiologia
Osteoblastos/patologia
Osteoclastos/patologia
Osteogênese/fisiologia
Oxigênio/análise
Porosidade
Propriedades de Superfície
Limites: Animais
Cães
Tipo de Publ: Estudo Comparativo
Research Support, Non-U.S. Gov't
Responsável: BR1.1 - BIREME


  7 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-479759
Autor: Braun, Ana Paula; Grassi Soares, Clarissa; Glüer Carracho, Helena; Pereira da Costa, Nilza; Bauer Veeck, Elaine.
Título: Optical density and chemical composition of microfilled and microhybrid composite resins
Fonte: J. appl. oral sci;16(2):132-136, Mar.-Apr. 2008. ilus, tab.
Idioma: en.
Resumo: This study evaluated the optical density of two microfilled and two microhybrid resins, as well as the composition of these materials with regard to their optical density. Cavities prepared in 12 2-mm- or 4-mm-thick acrylic plastic plates were filled with Z250 (3M-ESPE), A110 (3M-ESPE), Charisma (Heraeus-Kulzer) and DurafillVS (Heraeus-Kulzer). The resin increments (2-mm-thick) were light-cured for 40 s. Three 0.12-s radiographic exposures were made of each #2 acrylic plastic plate. DenOptix system optical plates were used to obtain the digital images. Three readings of the composite resin surface were made in each radiograph, totalizing 216 readings. The mean of highest and lowest grey-scale values was obtained. Two specimens of each composite resin were prepared for SEM analysis of the chemical elements related to optical density, using energy dispersive x-ray analysis (EDX). The results were subjected to Shapiro-Wilk's test, ANOVA, Tukey's test at 1 percent level of significance and Pearson's correlation. The mean grey-scale values at 2 mm and 4 mm were: Z250 = 154.27a and 185.33w; A110 = 46.77b and 63.05y; Charisma = 163.40c and 200.46z; DurafillVS = 43.92b and 58.99x, respectively. Pearson's test did not show any positive correlation between optical density and percentage weight of optical density chemical elements. It was concluded that the microhybrid resins had higher optical density means than the microfilled resins; among the evaluated resins, Charisma had the highest optical density means.
Descritores: Resinas Compostas/química
Materiais Dentários/química
-Alumínio/análise
Bário/análise
Fenômenos Químicos
Resinas Compostas/análise
Densitometria
Materiais Dentários/análise
Microanálise por Sonda Eletrônica
Processamento de Imagem Assistida por Computador
Teste de Materiais
Microscopia Eletrônica de Varredura
Fenômenos Ópticos
Radiografia Dentária
Propriedades de Superfície
Fatores de Tempo
Zinco/análise
Limites: Humanos
Tipo de Publ: Research Support, Non-U.S. Gov't
Responsável: BR1.1 - BIREME


  8 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Lima, Antonio Fernando Martorelli de
Texto completo
Id: lil-466505
Autor: Cruz, Gabriela Alessandra da; Toledo, Sérgio de; Sallum, Enilson Antonio; Lima, Antonio Fernando Martorelli de.
Título: Morphological and chemical analysis of bone substitutes by scanning electron microscopy and microanalysis by spectroscopy of dispersion energy
Fonte: Braz. dent. j;18(2):129-133, 2007. ilus, tab.
Idioma: en.
Resumo: This study evaluated the morphological and chemical composition of the following bone substitutes: cancellous and cortical organic bovine bone with macro and microparticle size ranging from 1.0 to 2.0 mm and 0.25 to 1.0 mm, respectively; inorganic bovine bone with particle size ranging from 0.25 to 1.0 mm; hydroxyapatite with particle size ranging from 0.75 to 1.0 mm; and demineralized freeze-dried bone allograft with particle size ranging from 0.25 to 0.5 mm. The samples were sputter-coated with gold in an ion coater, the morphology was observed and particle size was measured under vacuum by scanning electron microscopy (SEM). The chemical composition was evaluated by spectroscopy of dispersion energy (EDS) microanalysis using samples without coating. SEM analysis provided visual evidence that all examined materials have irregular shape and particle sizes larger than those informed by the manufacturer. EDS microanalysis detected the presence of sodium, calcium and phosphorus that are usual elements of the bone tissue. However, mineral elements were detected in all analyzed particles of organic bovine bone except for macro cancellous organic bovine bone. These results suggest that the examined organic bovine bone cannot be considered as a pure organic material.

Neste estudo foram avaliados a morfologia, o tamanho e a composição química dos seguintes substitutos ósseos: osso bovino orgânico cortical e esponjoso com micropartículas medindo entre 0,25 e 1,0 mm e macropartículas medindo entre 1,0 e 2,0 mm; osso bovino cortical inorgânico com partículas medindo entre 0,25 e 1,0 mm; hidroxiapatita com partículas medindo entre 0,75 e 1,0 mm; e osso humano descalcificado, congelado e seco medindo entre 0,25 a 0,5 mm. Para a analise da morfologia e tamanho das partículas, as amostras foram preparadas em porta-espécime, metalizadas em ouro e analisadas a vácuo em microscopia eletrônico de varredura (MEV). Para a análise da composição química, as partículas não foram metalizadas e foram analisadas por microanálise por espectroscopia por dispersão de energia (EDS). A análise em MEV, demonstrou que as partículas substitutos ossos apresentaram formato irregular e tamanho variável, maior do que o mencionado pelo fabricante. A microanálise por EDS detectou a presença de elementos como sódio, cálcio e fósforo, que são comuns à composição do tecido ósseo, porém revelaram a presença de elementos químicos nas partículas de osso bovino orgânico, exceto para a macropartícula de osso bovino orgânico esponjoso. Esses resultados sugerem que o osso bovino orgânico não pode ser considerado um material orgânico puro.
Descritores: Substitutos Ósseos/química
-Materiais Biocompatíveis/análise
Materiais Biocompatíveis/química
Substitutos Ósseos/análise
Osso e Ossos/química
Osso e Ossos/ultraestrutura
Criopreservação
Cálcio/análise
Técnica de Descalcificação
Durapatita/análise
Durapatita/química
Microanálise por Sonda Eletrônica
Liofilização
Microscopia Eletrônica de Varredura
Minerais/análise
Minerais/química
Tamanho da Partícula
Porosidade
Fósforo/análise
Sódio/análise
Transplante Homólogo
Limites: Animais
Bovinos
Humanos
Responsável: BR1.1 - BIREME


  9 / 29 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-447236
Autor: Carranza, Miriam L; Carda, Carmen; Simbrón, Alicia; Sánchez Quevedo, María C; Celaya, Gabriela; Gómez de Ferraris, María Elsa.
Título: Morphology of the lateral pterygoid muscle associated to the mandibular condyle in the human prenatal stage
Fonte: Acta odontol. latinoam;19(1):29-36, 2006. ilus, tab.
Idioma: en.
Resumo: El músculo pterigoideo lateral (MPL) establece una relación directa con el cóndilo y el disco articular, desempeñando un rol importante en el movimiento mandibular a través del complejo articular temporomandibular (CATM). El objetivo de este trabajo fue determinar la correspondencia entre las características morfológicas de los haces musculares del MPL y el grado de mineralización del cóndilo mandibular en la etapa prenatal, mediante un análsisi estructgural, ultraestructural y microanalítico. Se utilizaron 16 fetos humanos de 11 a 37 semanas de gestación, procedentes de abortos espontáneos y sin patologías aparentes. Se obtuvieron muestras del músculo pterigoideo lateral y cóndilo mandibular, para ser examinadas meidante microscopía ñoptica, electrónica y técnicas de microanálisis. Muestras incluidas en parafina se emplearon en los estudios de inmunomarcación con desmina (dilución 1:25 Dako) y alfa actina sarcómerica (dilución 1:50 Dako), visualizados con sistema avidina-biotina. El lado contralateral de cada una se utilizó para microscopía electrónica de transmisión. En 4 cóndilos de 17 y 21 semanas de desarrollo se analizó el contenido relativo de calcio y fósforo con la técnica microanalítica por difracción de rayos X. Entre las 11 y 16 semanas, el MPL estuvo contituido por miotubos secundarios asociados a céluals satélites y fascículos. La organización del músculo a las 37 semanas fue más compleja, con aspecto multipeniforme y con la edad se redujo la intensidad de la inmunomarcación con alfa actina sarcomérica. Estos resultados sugieren que entre las 16 y 22 semanas, el proceso de diferenciación y maduración de las fibras musculares precede y prevalece sobre el desarrollo y mineralización del cóndilo mandibular. La funcionalidad aún rudimentaria del MPL prenatal sería uno de los factores reguladores del proceso de osificación a nivel del cóndilo mandibular, cuyo ritmo aumentaría a partir de las 22 semanas de gestación
Descritores: Côndilo Mandibular/ultraestrutura
Estruturas Embrionárias
Desenvolvimento Fetal
Músculos Pterigoides/ultraestrutura
-Argentina
Feto
Microanálise por Sonda Eletrônica/métodos
Limites: Masculino
Humanos
Feminino
Gravidez
Responsável: AR29.1 - Biblioteca


  10 / 29 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Id: lil-428137
Autor: Dias, Alexandre Henrique de Moura; Myashita, Eduardo; Nono, Maria do Carmo de Andrade; Botttino, Marco Antonio.
Título: Avaliação mecânica e microestrutural da interface ceramo-cerâmica / Microstructural and mechanical evaluation of interface ceram-ceramic
Fonte: Ciênc. odontol. bras;8(2):31-38, abr.-jun. 2005. ilus, tab, graf.
Idioma: pt.
Resumo: O propósito deste estudo foi avaliar a resistência e caracterizar química e microestruturalmente, através da espectrometria dispersiva de raios X (EDX) e microscopia eletrônica de varredura (MEV), a interface ceramo-cerâmica de dois grupos: A)IPS Empress 2/Empress 2 cerâmico, B)In Ceram Alumina/Vitadur Alfa. Foram confeccionadas dez amostras de cada grupo composta de infra-estrutura que apresenta uma extremidade maior de dimensões de 5,0mm de diâmetro x 5,0mm de comprimento, um estreitamento de 1,0mm formando uma extremidade menor de 4,0mm de diâmetro x 2,0mm de comprimento, sendo esta superfície aplicada cerâmica de recobrimento apresentando 4,0mm x 3,0mm de comprimento. Os grupos A e B, foram submetidos ao teste de cisalhamento numa máquina Instron (modelo 4301) a uma velocidade de 0,5mm/min até a fratura. Os resultados foram avaliados utilizando ANOVA. A resistência ao cisalhamento do grupo A foi estatisticamente superior em relação ao grupo B, p<0,5, e microestruturalmente, foi observada no grupo B uma predominância de deslocamento total do recobrimento em relação a infra-estrutura, enquanto no grupo A observou-se um deslocamento parcial. Concluiu-se que o grupo A apresentou uma maior adesividade ceramo-cerâmica, quando avaliado mecânica e microestruturalmente
Descritores: Materiais Dentários
Microanálise por Sonda Eletrônica
Ligas Metalo-Cerâmicas
Microscopia Eletrônica de Varredura
Resistência ao Cisalhamento
-Análise de Variância
Tipo de Publ: Estudo Comparativo
Responsável: BR243.1 - Serviço Técnico de Biblioteca e Documentação



página 1 de 3 ir para página          
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde