Base de dados : LILACS
Pesquisa : E04.545.550.280.280.280 [Categoria DeCS]
Referências encontradas : 30 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 3 ir para página          

  1 / 30 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-619756
Autor: Cava Vergiu, Carlos Enrique; Aguilar Valle, Mónica; Flores Cueto, Walter Fernando.
Título: Extirpación de canino retenido y estabilización dental mediante implantes endodónticos / Canin retaineds extirpation and dental stabilization with endodontic implants
Fonte: Kiru;6(1):46-52, ene.-jun. 2009. ilus.
Idioma: es.
Resumo: El artículo reporta la extirpación de un canino retenido que originaba la reabsorción radicular de piezas dentarias antero superiores. El tratamiento fue realizado en el Centro Quirúrgico de la Clínica Especializada en Odontología de la Universidad San Martín de Porres, y consistió en la preparación biomecánica de los conductos radiculares de los dientes afectados, la remoción del canino retenido y la colocación de implantes trans endodónticos,obteniéndose un resultado funcional satisfactorio.

This report presents canin retaineds extirpation because it has caused radicular reabsortion on antero superior teeth and dental stabilization with endodontic implants. This procedure was performed in the Clinically Quirrgico Center of Specialized Dentistry, University of San Martín de Porres. The treatment consists of the root canal treatment of affected pieces, the removal of retained canin, and the transendodontic fixation. The case was resolved with acceptable functional results.
Descritores: Dente Impactado/cirurgia
Implantação Dentária Endo-Óssea Endodôntica
Limites: Humanos
Masculino
Adolescente
Tipo de Publ: Relatos de Casos
Responsável: PE264.3 - Biblioteca


  2 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Cuba
Texto completo
Texto completo
Id: biblio-901768
Autor: Álvarez Rodríguez, Javier; Wolfshon Manhard, Bernardo; Mier Sanabria, Mónica.
Título: Estabilizador Endodóntico en Fractura Complicada de Raíz en visita única / Endodontic Stabilizer in Complicated Root Fracture in a single visit
Fonte: Rev. habanera cienc. méd;16(5):761-769, set.-oct. 2017. ilus.
Idioma: es.
Resumo: Introducción: La fractura complicada de raíz del tercio medio es una entidad compleja de pronóstico mayormente desfavorable y curso sintomático, donde el éxito clínico en no pocas oportunidades se convierte en una utopía, dado que la estabilidad en el afrontamiento de los bordes libres de los fragmentos fracturados es difícil de lograr. En este sentido el estabilizador edodóntico busca garantizar un anclaje bilateral satisfactorio, que posibilite unificar en una consulta los tiempos operatorios necesarios para un tratamiento exitoso. Objetivo: Describir la factibilidad del uso de un estabilizador endodóntico en el manejo de una fractura complicada de raíz del tercio medio en una visita. Presentación del caso: Paciente de 60 años, femenina que acude a consulta tras sufrir traumatismo dentoalveolar consistente con fractura complicada de raíz del tercio medio en 21; a los rayos X se observa ligero ensanchamiento periodontal y bordes discontinuos. Se realiza tratamiento edodóntico radical mediante la aplicación de un estabilizador intraconducto en la reducción de la fractura. Conclusiones: El uso de un estabilizador endodóntico en el manejo de una fractura complicada de raíz del tercio medio realizado en una sola visita es una alternativa factible de realizar en el tratamiento mediato e inmediato, ya que supone una rápida recuperación de las funciones buco-dentales del paciente(AU)

Introduction:The complicated fracture of the medium third of the root is a complex entity, particularly with an unfavorable prognosis and a symptomatic course in which the clinical success becomes a utopia in not just a few opportunities because the stability by confrontation of the free edges of the fractured fragments is difficult to achieve. In this respect, the endodontic stabilizer is used to guarantee a satisfactory bilateral anchorage that gives the possibility to unify, in a single visit, the necessary operation times for a successful treatment. Objective: To describe the feasibility of the use of an endodontic stabilizer in the management of a complicated fracture of the medium third of the root in a single visit. Case presentation: Female 60-year-old patient who comes to the consulting room after suffering from a consistent dentoalveolar trauma with a complicated fracture of the medium third of the root in tooth no.21; radiograph reveals a slight periodontal widening, and discontinuous edges. Radical endodontic treatment is performed with the placement of an intraductal stabilizer in the reduction of the fracture. Conclusions: The use of an endodontic stabilizer in the management of a complicated fracture of the medium third of the root in a single visit to the dentist is a feasible alternative in the mediate and immediate treatment seeing that it supposes a fast recovery of the bucco-dental functions of the patient(AU)
Descritores: Fraturas dos Dentes
Raiz Dentária/lesões
Implantação Dentária Endo-Óssea Endodôntica/métodos
Limites: Humanos
Feminino
Pessoa de Meia-Idade
Responsável: CU1.1 - Biblioteca Médica Nacional


  3 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Texto completo
Id: biblio-967088
Autor: Klitynska, Oksana Vasilyevna; Maystruk, Pavel Olegovich; Hasiuk, Natalya Vladimirovna; Mochalov, Yuri Alexandrovich.
Título: Evaluation of Frontal Teeth Stabilization after Root Apex Resection among the Ukrainian Young People
Fonte: Pesqui. bras. odontopediatria clín. integr;18(1):4181, 15/01/2018. tab.
Idioma: en.
Resumo: Objective: To develop a protocol of improved stabilization of teeth after root apex resection among young people using endodonto-endoossal implants and assessing its effectiveness. Material and Methods: Thirty-six patients were previously selected and divided into Group 1 (without additional stabilization) and Group 2 (with additional stabilization). The efficacy of treatment in both clinical groups was estimated at 90, 180 and 360 days, respectively. The results were evaluated on the Miller scale in the Flesrar modification. Density of bone tissue was expressed in Hounsfield units. Results: The average mobility indices over 90 days indicate a significant lower mobility of teeth in patients in Group 2, where as an advanced method, the RTR with an additional filling of the bone marrow defect with an osteoplastic material was chosen as the method of treatment (+ 18.0 ± 0.21 U.M. 10.0 ± 0.8 µm, p<0.05). In Group 1, 90 and 180 days after surgery, the density of bone tissue in the defect area was 756.3 ± 2.45 HU and 880.1 ± 4.34 HU. In Group 2, these indices were insignificantly higher and amounted to 834.3 ± 4.35 HU and 880.4 ± 2.56 HU. After 360 days after treatment in the first clinical group the bone density index was 957.4 ± 2.45 HU, while in the second group - 1003.3 ± 4.38 HU. Conclusion: The mobility of teeth among patients on 90-th day corresponded to level 1, and on 360-th day corresponded to level 0, indicating the effectiveness of the proposed method. The biomechanical stabilization of the teeth was confirmed by the results of densitometry among patients of both groups, in particular, the recovery of bone density in the affected site was observed after 360 days.
Descritores: Raiz Dentária/anatomia & histologia
Ucrânia
Implantação Dentária Endo-Óssea Endodôntica
Endodontia
-Estatísticas não Paramétricas
Protocolos/métodos
Limites: Humanos
Masculino
Feminino
Adolescente
Adulto
Tipo de Publ: Estudo Comparativo
Estudo de Avaliação
Responsável: BR1822.9 - Associação de Apoio à Pesquisa em Saúde Bucal


  4 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: biblio-854418
Autor: Miguel, Ronaldo de Carvalho.
Título: Implantologia e Endodontia / Implantology and Endodontics
Fonte: RGO (Porto Alegre);34(5):402-3, set.-out. 1986.
Idioma: pt.
Descritores: Implantação Dentária Endo-Óssea Endodôntica
Tipo de Publ: Relatos de Casos
Responsável: BR97.1 - Serviço de Documentação Odontológica


  5 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Caldeira, Celso Luiz
Id: lil-781874
Autor: Caldeira, Celso Luiz.
Título: Testes pulpares: da "era do gelo" à "era tecnológica" / pulp tests: the \"Ice Age\" to the \"technological age\".
Fonte: São Paulo; s.n; 2014. 143 p. (BR).
Idioma: pt.
Tese: Apresentada a Universidade de São Paulo. Faculdade de Odontologia para obtenção do grau de Professor Livre Docente.
Símbolo: BR.
Resumo: Os testes pulpares fazem parte dos exames mais utilizados para identificar a saúde da polpa dentária, e podem ser qualificados como: testes de sensibilidade (como os testes térmicos e elétricos) e testes de vitalidade (como a Fluxometria Laser Doppler e a Oximetria de pulso). Os testes de sensibilidade, apesar de serem os mais utilizados, apresentam limitações importantes, pois avaliam a resposta nervosa sensorial à aplicação de estímulos e apenas pressupõem a condição de vitalidade da polpa. Já os testes de vitalidade, que analisam o suprimento sanguíneo ou o tecido vascular, mesmo com algumas limitações, são mais objetivos e avaliam o real estado fisiológico da polpa. Este trabalho discute o panorama atual da utilização dos testes pulpares, revê os fatores condicionantes da avaliação da polpa, mostra as vantagens e dificuldades de ambos testes de sensibilidade e vitalidade, e analisa as perspectivas do uso da tecnologia no diagnóstico endodôntico...

Among the most commonly used exams to identify the health of dental pulp are the pulp tests, which can be qualified as sensitivity tests (such as thermal and electrical test) or vitality tests (such as Laser Doppler Flowmetry and Pulse Oximetry). Sensitivity tests, despite being the most widely used ones, have important limitations, since they assess the responses of sensory nerves to an applied stimulus and can only presuppose the pulp vitality. Vitality tests, which analyze the blood supply or the vascular tissue, even with some limitations, are more objectives and can assess the real physiological status of the pulp. This work discusses the current panorama of the use of pulp tests, and revises the determining factors of pulp evaluation, showing the advantages and difficulties of both tests, sensitivity and vitality, and analyzing the prospects for the usage of technology in endodontic diagnosis...
Descritores: Implantação Dentária Endo-Óssea Endodôntica
Diagnóstico
Oximetria
Reologia
Limites: Humanos
Responsável: BR97.1 - Serviço de Documentação Odontológica


  6 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-686183
Autor: Cardenas, J. Edgar Valdivia; Beltrán, Enrique Hair Salas; Añaños, Felipe Hernández.
Título: Implantes endodônticos intraósseos de NiTi
Fonte: Dent. press endod;2(1):38-41, 2012. ilus.
Idioma: pt.
Resumo: Introdução: os implantes endodônticos são considerados uma extensão metálica intraóssea radicular de um dente.São indicados especialmente para estabilizar elementos dentários. Assim sendo, são considerados um artifício final para aumentar de forma artificial o comprimento radicular com a finalidade que o dente afetado possa suportar seu próprio dinamismo e função. Objetivo: o objetivo desse relato de caso clínico é apresentar um tratamento conservador para estabilizar e criar condições restauráveis para dois incisivos inferiores, nos quais foram implantados dois estabilizadores endodônticos intraósseos de níquel-titânio confeccionados a partir de limas endodônticas com a finalidade de restabelecer sua função no sistema dentário
Descritores: Implantação Dentária Endo-Óssea Endodôntica
Níquel
Tratamento do Canal Radicular
Titânio
Limites: Humanos
Masculino
Adulto Jovem
Responsável: BR510.1 - Biblioteca Central


  7 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-625036
Autor: Pasqualin, Fábio Henrique; Giovani, Alessandro Rogério; Sousa Neto, Manoel Damião de; Paulino, Silvana Maria; Vansan, Luiz Pascoal.
Título: In vitro fracture resistance of glass-fiber and cast metal posts with different designs / Resistência à fratura de pinos de fibra de vidro e metálicos fundidos com diferentes configurações
Fonte: Rev. odonto ciênc;27(1):52-57, 2012. tab.
Idioma: en.
Projeto: CAPES.
Resumo: PURPOSE: To evaluate the in vitro fracture resistance of roots with glass-fiber and metal dowels with different designs. METHODS: Fifty-endodontically treated maxillary central incisors were embedded in acrylic resin. Ten of them received only the coronary preparation, and the remaining forty were embedded (except for 4mm of the cervical area) after removing the clinical crowns. Specimens were divided into five groups (n=10): control (teeth with only coronary preparation), cylindrical cast dowel, conical cast dowel, cylindrical glass-fiber dowel and conical glass-fiber dowel. Specimens were subjected to an increasing compressive load (N) until fracture. RESULTS: ANOVA indicated significant difference (P<.05) among the groups, and the Tukey-Kramer´s test identified these differences. The control group (867±243 N) presented the highest values and was statistically similar to cylindrical glass-fiber dowel group (711±180 N). There is no significant difference among the metal dowel cylindrical (435±245 N) or conical (585±164 N) group and conical glass-fiber dowel (453±112 N). Cylindrical glass-fiber dowel (711±180 N) and conical cast dowel and core (585±164 N) groups had intermediate values and did not differ from each other. CONCLUSIONS: Cylindrical glass fiber dowels represent a viable alternative to the cast-metal dowel cylindrical or conical. Cylindrical glass fiber dowels also increase endodontically treated incisors' resistance to fracture.

OBJETIVO: Avaliou-se in vitro a resistência à fratura de raízes com pinos metálicos fundidos e de fibra de vidro, variando sua configuração geométrica. METODOLOGIA: Cinquenta incisivos centrais superiores tratados endodonticamente foram incluídos em resina acrílica. Dez receberam apenas preparo coronário (controle) e quarenta tiveram coroas seccionadas e raízes incluídas em resina (deixando 4 mm cervicais). Distribuiu-se os espécimes em 5 grupos: controle, pino metálico cilíndrico, metálico cônico, pino de fibra de vidro cilíndrico e cônico. Submeteram-se os corpos-de-prova a ensaio de compressão, até ocorrer a fratura. RESULTADOS: A ANOVA indicou diferença significante entre os grupos (P<.05) e no teste de Tukey-Kramer´s o controle (867±243 N) apresentou os maiores valores de resistência à fratura, sendo similar ao grupo do pino de fibra cilíndrico (711±180 N). Não houve diferença significante entre os pinos metálicos cilíndricos (435±245 N) ou cônicos (585±164 N) e os de fibra cônicos (453±112 N). Os grupos dos pinos de fibra cilíndricos (711±180 N) e pinos metálicos cônicos (585±164 N) apresentaram valores intermediários e não foram diferentes entre si. CONCLUSÃO: Pinos de fibra de vidro são uma alternativa viável ao pino metálico fundido cilíndrico e cônico. Os pinos de fibra cilíndricos aumentaram a resistência à fratura dos incisivos tratados endodonticamente.
Descritores: Implantação Dentária Endo-Óssea Endodôntica
Pinos Dentários
Técnicas In Vitro
-Restauração Dentária Permanente
Responsável: BR97.1 - Serviço de Documentação Odontológica


  8 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-582293
Autor: Klautau, Eliza Burlamaqui; Souza, Patrícia Silva e; Barros, Camila Maria Trindade Martins; Garcia, Viviane; Maranhão, Kalena de Melo.
Título: Radiographic evaluation of endodontic treatment and radicular retainer quality
Fonte: Salusvita;28(1):21-29, 2009. graf, tab.
Idioma: en.
Resumo: O propósito deste estudo foi avaliar radiograficamente a qualidade dos retentores intra-radiculares, região periapical e tratamentos endodônticos. Um total de 192 radiografias periapicais foram selecionadas da Clínica Odontológica do Centro Universitário do Pará– CESUPA. De acordo com os critérios radiográficos, a qualidade foi categorizada como adequada ou inadequada. Os dados analisados por meio do teste estatístico X2 demonstraram que o tratamento endodôntico apresentou inadequado em 53.64 por cento; a região periapical foi inadequada em 34.89 por cento; os elementos reabilitadores presentes apresentaram adaptação cervical inadequada em 51.85 por centoe os retentores intra–radiculares foram executados inadequadamente em 58.33 por cento...

The purpose of this study was to evaluate the quality of the coronalrestoration, radicular retainer, periapical status and root fi llingsscored on radiographic basis of endodontically treated teeth. Atotal of 192 periapical radiographs were randomly selected from CESUPA´S Dental School patients. According to the radiographic criteria, the technical quality was categorized as ´adequate` or ´inadequate`. The data analyzed by statistical X2 test demonstratedthat 53.64 per cent had inadequate endodontic treatment; teeth with anadequate root fi lling were associated with a better periapical statusthan teeth with inadequate root fi lling (65.1 per cent vs. 34.89 per cent); teeth with adequate and inadequate coronal restorations were 48,14 per cent and 51.85 per cent, respectively. This difference was not statistically signifi cant and the rate of inadequate root canal post and core was 58.33 per cent.
Descritores: Implantação Dentária Endo-Óssea Endodôntica
Limites: Humanos
Responsável: BR275.1 - Biblioteca


  9 / 30 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Laganá, Dalva Cruz
Texto completo
Id: lil-563878
Autor: Pigozzo, Mônica Nogueira; Laganá, Dalva Cruz; Noritome, Pedro Yoshito.
Título: Avaliação das tensões às estruturas de suporte, por meio do método fotoelástico, decorrentes das forças aplicadas sobre overdentures retidas em implantes com sistema de encaixe barra-clipe / Appraisal, by photoelastic method, of load transmission on support structures with overdentures retained in implants with bar-clip system
Fonte: Rev. odontol. Univ. Cid. Sao Paulo;22(2):122-133, maio-ago. 2010. ilus.
Idioma: pt.
Resumo: Introdução: O objetivo deste estudo é avaliar in vitro a transmissão de forças do sistema de retenção do tipo barra-clipe para overdenture, quando duas posições de implantes são simuladas, utilizando-se para isso as técnicas da análise fotoelástica. Métodos: Assim, duas mandíbulas fotoelásticas foram confeccionadas com dois implantes, posicionados na região interforaminal a 22mm de distância: modelo 1 - AFIP, modelo fotoelástico com implantes paralelos e orientados verticalmente; e modelo 2 - AFII, modelo fotoelástico com implantes angulados 10º em relação à linha média da mandíbula. Sobre os implantes foram instalados o sistema de retenção barra-clipe e uma prótese overdenture. Para simulação da mucosa oral, foi interposta, entre a prótese overdenture e a mandíbula fotoelástica, uma camada de 2mm de silicone. Cargas de 0,5; 1,0; 1,5; 2,0; e 3 bars foram aplicadas e as imagens analisadas. Resultados: Os resultados mostraram que não houve semelhança nas áreas de tensão entre os modelos de resina fotoelástica, quando avaliada a angulação dos implantes. Já o modelo1 AFIP apresentou maior concentração no ápice dos implantes e o modelo 2 AFII apresentou maior concentração na face mesial dos implantes. Conclusão: Considerando-se as limitações deste trabalho, concluiu-se que o método de análise fotoelástica é de grande valia para a obtenção de informação em relação à biomecânica referente a esse tipo de prótese e sistema de retenção.

Introduction: The main objective of this study is to appraise in vitro the load transmission in bar-clip retention system for overdenture when 2 implant position are simulated, using for this purpose the photoelastic analysis technique. Methods: Therefore, 2 photoelastic mandibles were manufactured with 2 implants each one, positioned in interforaminal region within 22 mm of distance: model 1 AFIP, photoelastic model with parallel and vertically oriented implants; and model 2 û AFII, photoelastic model with 10º angled implants in relation to mandible midline. A bar-clip retention system and an overdenture were fixed over both implants. To simulate oral mucosa were added a 2 mm silicon layer between overdenture prosthesis and photoelastic mandible. 0.5; 1.0; 1.5; 2.0 and 3.0 bars loads were applied and correspondent images were analyzed. Results: Results evidenced that: there is no similarity in loaded areas between photoelastic resin models, when the implant angle is appraised. Since in the model 1 - AFIP, the concentration area of tension was at implant apex and in the model 2 û AFII was at the distal face. Conclusion: Considering the limitations of this study, it was concluded that photoelastic analysis has a high potential value for obtaining information concerning the biomechanics of this kind of prosthesis and retention system.
Descritores: Implantação Dentária Endo-Óssea
Implantação Dentária Endo-Óssea Endodôntica
Mandíbula/fisiologia
Responsável: BR97.1 - Serviço de Documentação Odontológica


  10 / 30 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-472795
Autor: Simunek, A; Kopecka, D; Cierny, M; Krulichova, I.
Título: A six-year study of hydroxyapatite-coated root-form dental implants / Un estudio de seis años sobre implantes dentales de raíz con recubrimiento de hidroxiapatita
Fonte: West Indian med. j;54(6):393-397, Dec. 2005.
Idioma: en.
Resumo: BACKGROUND: The effect of hydroxyapatite coating of dental implants is controversial. The long-term fate of hydroxyapatite-coated implants has been the subject of some criticism. PURPOSE: The aim of this retrospective study was to assess the clinical outcome of hydroxyapatite-coated cylindrical root-form endosseous Impladent dental implants (LASAK Ltd, Prague, Czech Republic) during a six-year course. METHODS: Three-hundred and ninety-one consecutively placed implants were used in 169 patients and followed for four to six years. Interval and cumulative success of implants and prostheses survival was tabulated. Marginal bone loss was measured RESULTS: Of the total number of implants, 98.5achieved initial osseointegration. The cumulative success was 98.3after one year, 97.0after three years, 92.8after five years and 90.4after six years. The prostheses survival at the end of the study was 100for fixed bridges totally supported by implants, 96.5for fixed bridges with combined implant and tooth support, 94.2for single crowns, 90.9for mandibular overdentures and 81.3for maxillary overdentures. Marginal bone loss averaged 2.4 +/- 0.8 mm at the end of five years. CONCLUSION: The success rate of the investigated hydroxyapatite-coated implants was comparable with the data presented in the literature and with the results of the similar implants without hydroxyapatite-coating. However, the marginal bone loss was of interest. Longer monitoring of the implants is necessary.

ANTECEDENTES: El efecto del recubrimiento de los implantes dentales con hidroxiapatita es un asunto controversial. El destino a largo plazo de los implantes recubiertos con hidroxiapatita ha sido objeto de críticas. PROPÓSITO: El objetivo de este estudio retrospectivo fue evaluar los resultados clínicos de los implantes dentales endo-óseos de raíz con recubrimiento de hidroxiapatita de la marca Impladent (LASAK Ltd., Praga, República Checa), durante el transcurso de seis años. MÉTODOS: Un número de 391 implantes colocados consecutivamente, fueron usados en 169 pacientes, y sujetos a seguimiento por un período de 4 a 6 años. Se tabuló el éxito de lo implantes – por intervalos y de forma cumulativa – así como la supervivencia de las prótesis. Se midió la pérdida de hueso marginal. RESULTADOS: El 98.5% de los implantes alcanzó óseo-integración en la fase inicial. El éxito cumulativo fue de 98.3% después de un año, 97.0% después de tres años, 92.8% luego de cinco años, y 90.4% tras seis años. La supervivencia de las prótesis al final del estudio fue de 100% para puentes fijos soportados totalmente por implantes, 96.5% para puentes fijos con combinación de soporte sobre dientes e implantes, 94.2% para coronas solas, 90.9% para sobredentaduras mandibulares, y 81.3% para sobredentaduras maxilares. La pérdida marginal de hueso tuvo un promedio de 2.4 ± 0.8 mm al final de los cinco años.CONCLUSIÓN: La tasa de éxito de los implantes recubiertos con HA investigados, resultó comparable a los datos presentados en la literatura, y a los resultados de implantes similares sin revestimiento de HA. Sin embargo, la pérdida marginal de hueso fue una alerta: se necesita monitorear los implantes por un período más largo de tiempo.
Descritores: Materiais Revestidos Biocompatíveis
Implantação Dentária Endo-Óssea Endodôntica
Implantes Dentários
Planejamento de Prótese Dentária
Prótese Dentária Fixada por Implante
Durapatita
Osseointegração
-Perda do Osso Alveolar
Implantação Dentária Endo-Óssea Endodôntica
Falha de Restauração Dentária
Implantes Dentários/efeitos adversos
Prótese Dentária Fixada por Implante/efeitos adversos
Prótese Dentária Fixada por Implante/instrumentação
Estudos Retrospectivos
Fatores de Tempo
Resultado do Tratamento
Limites: Humanos
Masculino
Feminino
Pessoa de Meia-Idade
Tipo de Publ: Research Support, Non-U.S. Gov't
Responsável: BR1.1 - BIREME



página 1 de 3 ir para página          
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde