Base de dados : LILACS
Pesquisa : E05.196.922.500 [Categoria DeCS]
Referências encontradas : 10 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 1

  1 / 10 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Chile
Texto completo
Id: lil-734832
Autor: Fernández Godoy, Eduardo; González C, Héctor; Arias F, Roque; Batista Oliveira, Osmir; Fresno R, Consuelo; Martín Casielles, Javier; Letelier Pardo, Claudia.
Título: Influencia de 2 dentífricos con agentes desensibilizantes en la conductabilidad hidráulica dentinaria / Influence of two agents desensitizing toothpastes in hydraulic conductance dentin
Fonte: Rev. clín. periodoncia implantol. rehabil. oral (Impr.);7(3):157-163, dic. 2014. ilus, tab.
Idioma: es.
Projeto: Grant de Colgate-Palmolive-Chile.
Resumo: El objetivo del estudio fue determinar in vitro los efectos de agentes desensibilizantes de dentífricos sobre la conductancia hidráulica de la dentina. Se seleccionaron 60 terceros molares humanos sanos, recientemente extraídos, sin contacto oclusal, de pacientes entre 15-30 años, los cuales fueron limpiados, desinfectados (Tymol 0,1% durante 24 h) y conservados a temperatura ambiente en solución HBSS. Las coronas fueron seccionadas perpendicular al eje dentario mayor bajo abundante refrigeración, obteniendo un disco de 1 mm ± 0,1 mm de espesor por cada corona. Se trataron ambas superficies del disco con ácido ortofosfórico al 35% por 15 segundos. Los discos se separaron en los siguientes 3 grupos de tratamiento, de 20 discos cada uno: los que fueron cepillados (cepillo eléctrico Oral-B® Pro Salud Power) durante 2 minutos solo por su cara oclusal con a) Colgate® Sensitive Pro Alivio con tecnología pro arginina (Colgate-Palmolive, Estados Unidos); b) Sensodyne® Rápido Alivio (GlaxoSmitheKline, Reino Unidio), y c) agua destilada como control negativo. Los datos fueron analizados estadísticamente por medio de las pruebas de Kruskall-Wallis y Mann-Whitney. Los resultados expresados en µl*cm−2*min−1cm*H²O−1 como medias, separados por grupo fueron: a) 0,00650 (± 0,00384); b) 0,00800 (± 0,00472), y c) 0,03649 (± 0,03042). Con el estudio se pudo concluir que los 2 agentes desensibilizantes dentinarios presentan significativa disminución de la conductabilidad hidráulica en dentina. Se encontraron diferencias estadísticamente significativas entre el grupo control y Sensodyne® Rápido Alivio (p = 0,000) y entre el grupo control y Colgate® Sensitive Pro Alivio (p = 0,000). No se observó diferencia entre las 2 pastas dentales (p = 0,317).

The aim of the study was to determine the effects of agents toothpastes on the hydraulic conductance of dentin desensitizers "in vitro". We selected 60 third molars healthy humans, recently extracted without occlusal contact, of patients between 15-30 years, which were cleaned, disinfected (Tymol 0.1% per 24 hours) and preserved at T atmosphere solution for a maximum of 14 days. The crowns were sectioned perpendicular to the tooth axis under abundant refrigeration, obtaining a disc of 1 mm +/-0.1 mm. thickness for each Crown. Disks were separated into the following three groups of treatment, of 20 discs each, which were brushings (brush electrical Oral-B Pro health Power) for 2 minutes only by your face occlusal with; a) Colgate® Sensitive Pro relief with technology Pro arginine (Colgate-Palmolive, USA), b) Sensodyne® quick-relief (GlaxoSmitheKline, UK), and c) distilled water as a negative control. The data were statistically analyzed by Kruskall Wallis and Mann Whitney tests. The results expressed in µl*cm−2*min−1cm*H²O−1as stockings, separated by group were; a) 0,00650 (±0.00384), b) 0,00800 (±0,00472), c) 0 and 03649 (±0,03042). You could be concluded with the study that two dentin desensitizers agents present significant decrease in hydraulic conductance in dentin. Statistically significant differences were found between the group control and Sensodyne® fast relief (p = 0,000) and between group control and Colgate® Sensitive Pro relief (p = 0,000). There was no difference between the two toothpastes (p = 0,317).
Descritores: Dentifrícios
Permeabilidade da Dentina
Sensibilidade da Dentina
Dessensibilizantes Dentinários
-Técnicas In Vitro
Condutometria
Estudo Observacional
Pressão Hidrostática
Limites: Seres Humanos
Adolescente
Responsável: CL1.1 - Biblioteca Central


  2 / 10 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-619743
Autor: Paucarima Huanca, Germán; Huamantumba Espinoza, Iván Dante.
Título: Conductometría establecida con el Foramatron IV y la radiografía convencional: estudio in vivo / Establishment of the conductometry with the Foramatron IV and the conventional radiography study
Fonte: Kiru;7(1):13-16, ene.-jun. 2010. ilus.
Idioma: es.
Resumo: Objetivo: El presente trabajo tuvo como objetivo determinar la precisión y exactitud de un localizador apical, Foramatron IV, en la conductometría de piezas unirradiculares, ya sea con pulpa vital o no vital. Material y método: Se realizó un estudio clínico, comparativo en 30 pacientes de ambos sexos con edades entre 16 y 62 años de edad que requerían tratamiento de endodoncia. Se consideraron para el estudio tanto las piezas vitales como las que presentaban necrosis pulpar. Se comparó la exactitud en la medición de la longitud de trabajo utilizando el método radiográfico convencional, con radiografias periapicales y el localizador apical Foramatron IV. Resultados: Los resultados mostraron que al comparar la conductometría usando el uso del localizador apical Foramatron IV comparado con el uso de radiografias periapicales, habían diferencias significativas (p= 0,0005) llegando el localizador apical al 96 % de exactitud, mientras que con el método radiográfico, se obtuvo una exactitud de 56%. No se encontró diferencia significativa en la exactitud de la conductometría de acuerdo a la vitalidad pulpar de las pizas dentarias (p=1,000). Conclusiones: el localizador apical Foramatron IV es más eficaz para determinar la conductometría in vivo que el método radiográfico convencional.

Objective: This study aimed to determine the accuracy and correctness of an apical locator Foramatron IV in single-rooted pieces, either vital or nonvital pulp Material and method: We conducted a clinical study, comparing 30 patients of both sexes, aged between 16 and 62 years old who required root canal treatment. This study has as objective to determine the accuracy and correctness of an apical locator, Foramathon IV on the canal of single rooted pieces, either with vital or nonvital pieces. We compared the accuracy in measuring the working length using conventional radiographic method with the locator Periapical and apical Foramatron IV. Results: The results showed that when comparing a clinical comparative study was made with 30 patients of both sexes,aged between 16 and 62 years old who requerided root canal treatment. Vital and nonvital pieces were considered for the study. Accurancy in measuring the work lenght was compared using conventional radiographic method, with periapical radiograpghic method with periapical radiographics and the apical locator, Formaton IV compared with the use of periapical radiographs, there were significant differences (p = 0.0005) reaching the apex locator to 96% accuracy, whereas radiographic method, we obtained an accuracy of 56%. No significant difference in the accuracy of radiograph according to the vitality of the pizzas dental pulp (p = 1.000). Conclusions: apex locator Foramatron IV is more effective in determining the radiograph in vivo, that the conventional radiographic method.
Descritores: Condutometria
Radiografia Dentária
-Estudos Transversais
Limites: Seres Humanos
Masculino
Adolescente
Adulto
Meia-Idade
Feminino
Tipo de Publ: Estudo Comparativo
Responsável: PE264.3 - Biblioteca


  3 / 10 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-569926
Autor: Rodríguez M., María Isabel.
Título: Longitud de trabajo en endodoncia / Working length in endodontics
Fonte: Rev. Estomat;2(2):105-108, dic. 1992.
Idioma: es.
Resumo: En la actualidad existen muchos métodos para determinar la longitud de trabajo o conductometria en endodoncia. Entre ellos podemos mencionar el método de Ingle, basado en la medición previa del conducto en la radiografía y luego introducir el instrumento hasta esa longitud y verificar radiográficamente; el de combinar la sensación táctil con verificación radiográfica; basarse en longitudes promedio, fórmulas matemáticas como la propuesta por Kuttler y aparatos electrónicos. La literatura actual aboga por la utilización de estos últimos por ser aparatos confiables pero han presentado varias limitaciones las que impiden que se popularicen en nuestro medio. En endodoncia aún hoy en día se trabaja muy "a ciegas" y aunque seguramente en el futuro se deberá tener menos confianza en la radiografía, actualmente es importante que se combine el criterio clínico del operador con una interpretación racional de la radiografía, para obtener una adecuada longitud de trabajo.

In endodontics is of great importance to choose an appropiate work system, for which literature has reported various methods in which the the electronic equipments seem to be trustfull, although they have several limitations. In our system, the trational method is based on X-Ray and the clinic dentist's judgment continue being the best chose.
Descritores: Endodontia/instrumentação
Endodontia/métodos
-Condutometria
Radiografia Dentária
Radiologia
Tipo de Publ: Revisão
Responsável: CO331 - Escuela de Odontologia


  4 / 10 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-534428
Autor: Aydemir, Hikmet; Ceylan, Gözlem; Tasdemir, Tamer; Kalyoncuoglu, Elif; Isildak, Ibrahim.
Título: Effect of immediate and delayed post space preparation on the apical seal of root canals obturated with different sealers and techniques
Fonte: J. appl. oral sci;17(6):605-610, Nov.-Dec. 2009. tab.
Idioma: en.
Resumo: During mechanical preparation of the post space, the root canal filling may be twisted or vibrated, depending on several factors associated with the preparation technique and quality of filling. OBJECTIVE: The purpose of this study was to investigate the effect of immediate and delayed post space preparation on the integrity of the apical seal. MATERIAL AND METHODS: Sixty-four extracted human incisors were biomechanically prepared using the step-back technique. Sixty roots were randomly assigned to 6 experimental groups of 10 teeth each and the remaining 4 roots served as positive and negative controls (n=2). The root canals in the different groups were obturated with cold lateral and warm vertical condensation of gutta-percha and one of two sealers (Sealapex and Diaket). Post space was prepared either individually or simultaneously. An insulated copper wire was cut into 10-cm-long pieces. In each canal, one piece was inserted to maintain contact with gutta-percha and extended to the outside as one of two working electrodes. A stainless steel wire with the same dimensions of those of the copper wire, used as the other working electrode, was immersed into the background electrolyte from the center of the bottle. The electrical current between standard and experimental electrodes in canals was measured over a period of 10 days applying a conductivity meter. The Kruskal-Wallis test (p=0.05) determined whether there was a significant difference in microleakage among the groups and the Mann-Whitney U test (p=0.01) was used for multiple comparison grouping variables. RESULTS: The results suggest that only the differences between the root canal filling techniques were statistically significant (p<0.01). There were no statistically significant difference in the sealers and the times of filling removal for post space preparation (p>0.01). CONCLUSION: The quality of the root canal filling is important for the integrity of the apical seal.
Descritores: Colagem Dentária
Cavidade Pulpar/patologia
Técnica para Retentor Intrarradicular
Materiais Restauradores do Canal Radicular/uso terapêutico
Obturação do Canal Radicular/métodos
Preparo de Canal Radicular/métodos
-Bismuto/uso terapêutico
Hidróxido de Cálcio/uso terapêutico
Condutometria/instrumentação
Condutometria/métodos
Combinação de Medicamentos
Infiltração Dentária/classificação
Eletrodos
Guta-Percha/uso terapêutico
Incisivo/patologia
Teste de Materiais
Polivinil/uso terapêutico
Salicilatos/uso terapêutico
Fatores de Tempo
Óxido de Zinco/uso terapêutico
Limites: Seres Humanos
Tipo de Publ: Estudo Comparativo
Ensaio Clínico Controlado Aleatório
Responsável: BR1.1 - BIREME


  5 / 10 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-503068
Autor: Anon.
Título: Ayudas radiográficas en la detección de conductos radiculares extra / Radiographic aids in the detection of extra root canals
Fonte: Rev. Asoc. Odontol. Argent;96(3):273-275, jun.-jul. 2008.
Idioma: es.
Resumo: Un estudio cuidadoso de toda radiografía es esencial para un tratamiento endodóntico. La Rx de conductometría es tanto la más importante en la localización de conductos extra como la más descuidada. Un cambio agudo en la densidad radiográfica del espacio del conducto indica un único ancho que se divide en dos más finos. Este signo radiográfico no está limitado a ningún diente particular, pero se ve más a menudo en los dientes anteriores inferiores y los premolares superiores. Se encontró que el primer molar superior tenía cuatro conductos tratables en 52, de 103 casos tratados clínicamente. El cuadro conducto se encontró usualmente 1 a 4mm por palatino del conducto M-V principal. Aunque la mayoría de estos conductos mesiovestibulares extra se reunían con el principal, muchos tenían forámenes separados completamente
Descritores: Radiografia Dentária/métodos
Radiografia Dentária
Tratamento do Canal Radicular/efeitos adversos
Tratamento do Canal Radicular/métodos
Tratamento do Canal Radicular
-Condutometria
Responsável: AR29.1 - Biblioteca


  6 / 10 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-294668
Autor: Hilú, Rodolfo Elías.
Título: Estudio in vivo del localizador apical Formatron IV en la determinación de la longitud de trabajo / An in vivo study of the Foramatron IV apex locator in working length determination
Fonte: Rev. Asoc. Odontol. Argent;89(4):427-9, jul.-ago. 2001. ilus.
Idioma: es.
Resumo: El objetivo de este estudio fue evaluar la precisión en la determinación de la longitud de trabajo de 97 conductos radiculares de 63 pacientes que necesitaban tratamiento endodóntico, con la utilización del localizador apical electrónico Formatron IV y el método radiográfico. Los resultados mostraron un total de 53,64 por ciento de mediciones aceptables. No se hallaron diferencias estadísticamente significativas entre las mediciones realizadas en pulpa vital, pulpa no vital y retratamiento (p=0,418). En las condiciones de este estudio el método radiográfico mostró mayor confiabilidad para la obternción de la longitud de trabajo
Descritores: Ápice Dentário
Condutometria/instrumentação
Preparo de Canal Radicular/métodos
-Distribuição de Qui-Quadrado
Cavidade Pulpar/anatomia & histologia
Limites: Seres Humanos
Responsável: AR29.1 - Biblioteca


  7 / 10 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-262317
Autor: Martínez Lalis, Ricardo; Testa, Rodolfo; Testa, Martha; Martínez Lacarrere, Tomás; Monti, Graciela.
Título: M4: Conformación del conducto con diferentes limas / M4: Shape of the root canal with differents files
Fonte: Rev. Asoc. Odontol. Argent;88(3):221-4, mayo-jun. 2000. ilus, tab.
Idioma: es.
Resumo: Se utilizaron tres tipos distintos de limas flexibles con la pieza de mano Safety M4 y se analizó el grado de deformación durante la preparación quirúrgica en tacos de acrílico. En la mayoría de los casos se observó un incremento en la deformación del conducto en los tercios medio y apical a medida que aumentaba el calibre del instrumento. Con la lima Onyx R se observo el menor grado de deformación, mientras que con la lima Flexicut se observaron los valores más altos.
Descritores: Condutometria/estatística & dados numéricos
Instrumentos Odontológicos/estatística & dados numéricos
Preparo de Canal Radicular/instrumentação
-Raiz Dentária
Tipo de Publ: Estudo Comparativo
Responsável: AR29.1 - Biblioteca


  8 / 10 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-200131
Autor: Gani Artola, Omar Abdo.
Título: Conductos múltiples y calidad de instrumentación en primeros molares inferiores permanentes de niños / Multiple root canals and instrumentation quality in children's permanent mandibular first molars
Fonte: Rev. Asoc. Odontol. Argent;85(4):381-6, ago.-sept. 1997. ilus.
Idioma: es.
Resumo: Se utilizaron 16 primeros molares inferiores extraídos de niños menores de 13 años, divididos en dos grupos (A y B) de 8 dientes cada uno. En las raíces mesiales de ambos grupos se localizaron y colocaron instrumentos en los conductos bucales, linguales y conductos intermedios, procediendo de igual modo en las raíces distales. Posteriormente se radiografiaron a manera de conductometría todas las raíces en sentido bucolingual y mesiodistal. Los conductos fueron instrumentados mediante técnicas estandarizadas y lavados abundantemente con hipoclorito de Na al 2,5 por ciento, incorporando el uso de fresas de Gates-Glidden en los del grupo B. Luego de secados, se llenaron con pintura roja y se obtuvieron cortes transversales en distintos niveles. La evaluación de la instrumentación demostró que era muy deficiente en todos ellos, salvo en las proximidades del foramen, donde se observaron algunas preparaciones aceptables. Estas últimas guardaban relación con el uso de las fresas de Gates-Glidden y sobre todo con conductos que se bifurcaban en el extremo apical. La instrumentación de conductos acintados simulando la presencia de varios contribuyó a aumentar la superficie dentinaria trabajada, obteniendo, no obstante, escasos resultados satisfactorios
Descritores: Qualidade da Assistência à Saúde/estatística & dados numéricos
Cavidade Pulpar/anatomia & histologia
Dentição Permanente
Técnicas In Vitro
Preparo de Canal Radicular/instrumentação
-Condutometria
Dente Molar/anatomia & histologia
Raiz Dentária/anatomia & histologia
Hipoclorito de Sódio/uso terapêutico
Limites: Seres Humanos
Masculino
Feminino
Tipo de Publ: Estudo Comparativo
Responsável: AR29.1 - Biblioteca


  9 / 10 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-83510
Autor: Calzadella Reyes, Adolfo.
Título: Determinación de la longitud de trabajo de los conductos radiculares a través de métodos electrónicos / Electronic determination of root canal length work.
Fonte: s.l; s.n; feb. 1989. 92 p. ilus, tab.
Idioma: es.
Resumo: Se realiza una revisión bibliográfica, que permite comparar, a través de los resultados la efectividad de la conductometria electrónica con la obtenida por métodos convencionales dando a conocer resultados obtenidos, confiabilidad y establecer ventajas y desventajas de este método..
Descritores: Condutometria/métodos
Polpa Dentária/efeitos da radiação
Endodontia
Tratamento do Canal Radicular/instrumentação
Tipo de Publ: Revisão
Responsável: VE70.1 - Biblioteca Dr Focion Febres Cordero
VE70.1/TPG77*C171


  10 / 10 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Id: lil-50935
Autor: Acosta Vigouroux, Sergio Alberto; Concha T., Eugenia; Melo G., Oriana; Salas M., Eugenia.
Título: Condiciones clínicas que alteran la medición electrónica de conductos
Fonte: Odontol. chil;33(2):90-5, dic. 1985. ilus, tab.
Idioma: es.
Descritores: Condutometria
Cavidade Pulpar
Responsável: AR29.1 - Biblioteca



página 1 de 1
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde