Base de dados : LILACS
Pesquisa : E06.292 [Categoria DeCS]
Referências encontradas : 309 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 31 ir para página                         

  1 / 309 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Reston, Eduardo Galia
Texto completo
Id: biblio-1135547
Autor: Vicentin, Morgana; Portella, Fernando Freitas; Reston, Eduardo Galia; Braga, Carlos; Bianchi, André Luis; Arossi, Guilherme Anzilliero.
Título: Evaluation of Tensile Bond Strength of Metallic Prefabricated Posts Cemented with Different Luting Agents
Fonte: Pesqui. bras. odontopediatria clín. integr;20:e4009, 2020. tab, graf.
Idioma: en.
Resumo: Abstract Objective: To assess the tensile bond strength of prefabricated metal posts cemented with different luting agents. Material and Methods: Fifty single-rooted endodontically treated human teeth had their crowns cut, mounted into acrylic-resin blocks and then an 8mm depth post space were prepared. Prefabricated cylindrical metal posts were cemented using different luting agents: a zinc phosphate cement (SS White), a conventional glass ionomer cement (Vidrion C), two resin-modified glass ionomer cements (Vitremer and RelyX Luting 2) and a resin cement (RelyX ARC). Samples were stored in distilled water for seven days and then submitted to a tensile bond strength test until complete dislocation of the post. One-way analysis of variance and Tukey test for pairwise multiple comparisons were used to evaluate differences between luting agents. Results: Tensile bond strength was 563.88±203.41 N for zinc phosphate cement, 336.86 ± 137.64 N for Vidrion C, 515.24 ± 239.48 N for Vitremer, 828.47±433.99 N for RelyX Luting 2 and 1262.51 ± 356.29 for RelyX ARC. The Relyx ARC presented the highest tensile bond strength regard the luting agent tested (p< 0.05). Conclusion: RelyX ARC presented the higher tensile bond strength compared to the other luting agents evaluated.
Descritores: Resistência à Tração
Cimentos de Resina
Cimentos Dentários
Cimentos de Ionômeros de Vidro
-Cimento de Fosfato de Zinco
Brasil/epidemiologia
Análise de Variância
Estatísticas não Paramétricas
Dente não Vital/diagnóstico
Pinos Dentários
Tipo de Publ: Estudo Comparativo
Estudo de Avaliação
Responsável: BR1264.1 - Biblioteca Setorial Prof Alberto M Campos


  2 / 309 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-1177776
Autor: El-Enein, Yasmin Abou; Elguindy, Jylan; Zaki, Amina A.
Título: One year clinical evaluation of e-max press crowns retained with fiber reinforced composite post versus e-max press endocrowns in anterior endodontically treated teeth (a randomized clinical trial) / Avaliação clínica de um ano de coroas e-max retidas com resina composta reforçada por fibra versus endocrowns de e-max em dentes anteriores tratados endodonticamente: um ensaio clínico randomizado
Fonte: Braz. dent. sci;24(2):1-12, 2021. tab, ilus, graf.
Idioma: en.
Resumo: Objective: The purpose of this study was to assess patient satisfaction, gross fracture and marginal adaptation of e.max press endocrowns versus e.max press crowns retained with Fiber reinforced composite post (FRCP) and core in upper anterior teeth. Material and methods: The present study included 24 patients seeking root canal treatment in anterior upper arch. The patients received root canal treatment (RCT) then they were randomly assigned into two groups (n=12). The first group received preparation for the IPS e.max crowns retained with FRCP and core and the second group received preparation for the IPS e.max endocrowns. Press technique was used for the fabrication of both restorations using IPS e.max press ingots. Marginal integrity and gross fracture were evaluated using USPHS criteria and a questionnaire was conducted to evaluate patient satisfaction. Data were analyzed using IBM SPSS Statistics for Windows, Version 23.0. Armonk, NY: IBM Corp. Results: There was no statistical significant difference regarding gross fracture of both groups after 12 months (p-value = 0.093, Effect size = 0.447), meanwhile; group 1 was statistically significantly higher than group 2 regarding marginal integrity (p-value = 0.037, Effect size = 0.513). Regarding patient satisfaction FRCP and core group showed statistical significant higher satisfaction than endocrown group (p-value = 0.047, Effect size = 0.447). Conclusion: E.max press endocrowns revealed successful performance similar to e.max press crowns retained with FRCP in terms of gross fracture, however better marginal adaptation and patient satisfaction was obtained with e.max press crowns retained with FRC post and core group. (AU)

Objetivo: O objetivo deste estudo foi avaliar a satisfação do paciente, grau de fratura grosseira e adaptação marginal de endocrowns e.max versus coroas de e.max retidas com pino de compósito reforçado com fibra (FRCP) e núcleo nos dentes anteriores superiores. Material e métodos: O presente estudo incluiu 24 pacientes que buscavam tratamento endodôntico na arcada superior anterior. Os pacientes receberam tratamento de canal radicular (RCT) e foram divididos aleatoriamente em dois grupos (n = 12). O primeiro grupo recebeu preparação para as coroas IPS e.max retidas com FRCP e núcleo e o segundo grupo recebeu preparos para as endocrowns IPS e.max. A técnica de prensagem foi usada para a fabricação de ambas as restaurações usando os lingotes de prensagem IPS e.max. A integridade marginal e a fratura macroscópica foram avaliadas usando os critérios da USPHS e um questionário foi realizado para avaliar a satisfação do paciente. Os dados foram analisados usando IBM SPSS Statistics for Windows, versão 23.0. Armonk, NY: IBM Corp. Resultados: Não houve diferença estatisticamente significativa em relação à fratura bruta de ambos os grupos após 12 meses (p-valor = 0,093, tamanho do efeito = 0,447), entretanto; o grupo 1 foi estatisticamente significativamente maior do que o grupo 2 em relação à integridade marginal (p-valor = 0,037, tamanho do efeito = 0,513). Em relação à satisfação do paciente, o FRCP e o grupo principal mostraram maior satisfação estatisticamente significativa do que o grupo endocrown (p-valor = 0,047, tamanho do efeito = 0,447). Conclusão: as endocrowns E.max press revelaram um desempenho bem-sucedido semelhante às coroas e.max press retidas com FRCP em termos de fratura bruta, no entanto, melhor adaptação marginal e satisfação do paciente foram obtidas com as coroas e.max press retidas com pilar FRC e núcleo de preenchimento (AU)
Descritores: Tratamento do Canal Radicular
Adaptação Marginal Dentária
Dente não Vital
Pinos Dentários
Limites: Humanos
Adulto
Pessoa de Meia-Idade
Tipo de Publ: Estudo Comparativo
Responsável: BR243.1 - Serviço Técnico de Biblioteca e Documentação


  3 / 309 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-744269
Autor: Colombo, Lívia Mourão Pereira Costa; Matafora, Flavia Lins; Moro, André Fábio Vasconcelos.
Título: Condicionamento de superfícies na Odontologia com plasma de argônio: uma revisão de literatura / Conditioning surfaces in Dentistry with argon plasma: a literature review
Fonte: Rev. bras. odontol;71(1):85-88, Jan.-Jun. 2014.
Idioma: pt.
Resumo: O objetivo deste estudo foi de verificar, por meio de revisão de literatura, os resultados do tratamento de diferentes superfícies de interesse para a Odontologia com gás argônio, um plasma frio à pressão atmosférica. Este vem sendo recentemente estudado e aplicado com o intuito de aumentar a molhabilidade do substrato condicionado, como zircônia, um material conhecidamente ácido resistente; dentina e pinos de fibra de vidro, interferindo positivamente na adesão. Diferentes estudos foram revisados, podendo-se concluir que o condicionamento com plasma frio de argônio alterou a superfície dos substratos testados, aumentando a área de superfície e, com isso, reduzindo o ângulo de contato. Isto contribui para uma maior molhabilidade do substrato e aumento da adesão às superfícies testadas.

The aim of this study was to verify, by means of literature review, the results of treatment of different areas of interest to Dentistry with Argon gas, a cold atmospheric pressure plasma. This subject has recently been studied and applied in order to increase the wettability of the substrate conditioning as zirconia, a well known acid-resistant material; Pins and dentin fiberglass positively interfering in adhesion. Different studies were reviewed, and shall be concluded that conditioning with cold argon plasma altered the surface of substrates, increasing the surface area and thereby reducing the contact angle. This contributes to a greatter wettability of the substrate and increased adherence to surfaces tested.
Descritores: Argônio
Zircônio
Pinos Dentários
Dentina
Responsável: BR485.1 - Biblioteca Mário Badan


  4 / 309 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-744239
Autor: Abreu, Rinaldo; Schneider, Maurício; Arossi, IIGuilherme Anziliero.
Título: Reconstrução anterior em resina composta associada a pino de fibra de vidro: relato de caso / Anterior tooth reconstruction with composite resin and fiber reinforced aesthetic pin: case report
Fonte: Rev. bras. odontol;70(2):156-159, Jul.-Dez. 2013. ilus.
Idioma: pt.
Resumo: A estética é uma preocupação do ser humano, tendo o sorriso nesse contexto um papel fundamental. O uso da faceta em resina composta está indicado para casos de grande perda de estrutura dentária vestibular. O objetivo deste trabalho é apresentar a confecção de faceta direta em resina composta no dente incisivo central superior direito (11) de um paciente com prejuízo estético e funcional. O trabalho salienta desde a urgência até a manutenção de saúde bucal, passando pelas fases de limpeza, cimentação do pino e construção da restauração, proporcionado por um tratamento integrado de diferentes especialidades.

Aesthetics are a concern of human beings with the smile in this context a crucial role. The use of facet composite resin is indicated for cases of severe loss of tooth structure entrance. The objective of this paper is to present the making of facet direct composite resin in upper right central incisor (11) of a patient with disfigurement and functional. The paper stresses the urgency since to maintaining oral health, through the stages of cleaning, cementing the pin and construction of restoration provided by an integrated treatment of different specialties.
Descritores: Cárie Dentária
Pinos Dentários
Facetas Dentárias
Responsável: BR485.1 - Biblioteca Mário Badan


  5 / 309 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-518050
Autor: icvila, Gisseli Bertozzi; Dias, Sérgio Cândido; Ribeiro, José Carlos Rabelo; Gomes, Priscila Nogueira; Moysés, Marcos Ribeiro.
Título: Análise da fragilidade do Core- quando reconstruído com diferentes resinas e pinos pré-fabricados não metálicos / Analysis of the Core frailty whenever reconstructed with different composites resins and prefabricated no-metallic
Fonte: Arq. odontol;43(2):4-8, 2007. tab.
Idioma: pt.
Resumo: Para realização deste estudo vinte condutos artificiais foram construídos em blocos formados por esmaltee dentina, a partir de dentes bovinos. Dez pinos de fibra de vidro e dez de fibra de carbono foram cimentadosnos condutos com cimento resinoso C&B. Empregou-se matriz de policarbonato para confecção do coreem resina composta, perfazendo quatro grupos: Grupo (1) pino de fibra de vidro e core com resina compostaCharisma; Grupo (2) pino de fibra de carbono e core com resina composta Charisma; Grupo (3) pino defibra de vidro e core com resina composta reforçada Enforce-core; Grupo (4) pino de fibra de carbono ecore com resina composta reforçada Enforce-core. Os ensaios mecânicos de compressão foram realizadosna máquina universal de ensaios EMIC DL 2000, com célula de carga 2000kgf e velocidade 1mm/mim.Verificou-se diferença estatística (p<0,05) (ANOVA) somente do fator resina no que tange as medidas daresistência à fratura do core, além disso, não há uma influencia significativa do tipo de fibra e nem mesmoda interação entre os fatores (resina x fibra). A conclusão para um fator é a mesma independentemente donível do outro fator. Os resultados para os dentes com resina composta reforçada diferem significativamentedos dentes que utilizaram resina composta não reforçada, onde, os dentes com resina composta reforçadaapresentaram medidas de resistência significativamente superiores aos dentes que utilizaram resina compostanão reforçada, independentemente do tipo de fibra (Teste de DUNCAN). Portanto, a fibra não influencia noresultado de resistência.
Descritores: Pinos Dentários
Resinas Compostas/uso terapêutico
Resinas/análise
-Cimentos de Resina/uso terapêutico
Interpretação Estatística de Dados
Moldes Cirúrgicos
Limites: Bovinos
Responsável: BR365.1 - BIB - Biblioteca


  6 / 309 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-549718
Autor: Gavranovi-Glamo, Alma; Ajanovi, Muhamed; Redepagi, Sead; Kazazi, Lejla.
Título: Comparing the retention of cast posts cemented with three different kinds of cement / Comparação da retenção de pinos fundidos cimentados com três tipos de cimento
Fonte: Pesqui. bras. odontopediatria clín. integr;10(1):41-45, jan.-abr. 2010.
Idioma: pt.
Resumo: Objective: To check and compare the retention of cast posts cemented with three different kinds of cement. Method: Forty five 45 human permanent maxillary incisors were randomly divided into three groups of 15 teeth. Root canals were prepared for the cast posts up to 8.5mm in length. The cast post obtained randomly were cemented with the help of the three cements (Zinc Phosphate, Glass-ionomer and resin modified Glass-ionomer [hybrid] cement). After cementation, the samples were stored in a physiological solution for seven days, after which we concluded the measure of retentive strength with the help of the universal testing machine (Zwick num. 112627, Ulm-Germany). Results: The hybrid cement has the greatest means value for retention and it is 312.90 N. It is followed by the Glass-ionomer cement with 272.40 N, while the Zinc Phosphate has the least, at 312.90 N. The statistical analysis shows that there is a statistical difference in the retention strength between the Zinc Phosphate cement and the Glass-ionomer (p<0.01), between the Zinc Phosphate cement and the hybrid cement (p<0.01). Conclusion: A significant statistical discrepancy was not manifested between the Glass-ionomer cement and the hybrid cement even though the difference in retention strength for these two cements was around 40 N.

Objetivo: Verificar e comparar a retenção de pinos fundidos cimentados com três diferentes tipos de cimento. Método: Quarenta e cinco incisivos superiores permanentes humanos foram divididos aleatoriamente em três grupos de 15 dentes cada um. Os canais radiculares foram preparados para receberem pinos fundidos de até 8.5 mm de comprimento. Os pinos foram cimentados com um dos três tipos de cimentos a seguir: cimento de fosfato de zinco, cimento de ionômero de vidro e cimento de ionômero de vidro modificado por resina (híbrido). Após a cimentação, as amostras foram armazenadas em solução salina durante 7 dias e então submeti das à análise da força de retenção em máquina universal de ensaios (Zwick num. 112627, Ulm-Germany). Resultados: O cimento híbrido apresentou o maior valor médio de retenção (312.90 N), seguido do cimento de ionômero de vidro (272.40 N) e do cimento de fosfato de zinco (312.90 N). A análise estatística mostrou diferença estatisticamente significante nos valores de retenção entre o cimento de fosfato de zinco e o cimento de ionômero de vidro (p<0,01), e entre o cimento de fosfato de zinco e o cimento híbrido (p<0,01). Conclusão: Não houve discrepância significativa entre o cimento de ionômero de vidro e o cimento híbrido, embora a diferença na força de retenção entre os dois materiais tenha sido de aproximadamente 40 N.
Descritores: Técnica para Retentor Intrarradicular
Cavidade Pulpar
Cimento de Fosfato de Zinco
Cimentos de Ionômeros de Vidro
Cimentos de Resina
Pinos Dentários
Preparo de Canal Radicular/métodos
Resistência à Tração
-Análise de Variância
Limites: Humanos
Tipo de Publ: Estudo Comparativo
Responsável: BR1264.1 - Biblioteca Setorial Prof Alberto M Campos


  7 / 309 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-536680
Autor: Gomes, Giovana Mongruel; Mendes, Yasmine Bittencourt Emílio; Lawder, Juliana Aparecida de Campos; Baggio, Rafael; Martins, Gislaine Cristine; Gomes, Osnara Maria Mongruel; Gomes, João Carlos; Santos, Elizabete Brasil dos.
Título: Avaliação de produtos naturais e sintéticos no controle da aderência de Enterococcus faecalis em pinos estéticos / Evaluation of natural and synthetic products at the control of enterococcus faecalis adherence on aesthetic fiber posts
Fonte: Odontol. clín.-cient;8(4):349-352, out.-dez.2009. graf, tab.
Idioma: pt.
Resumo: A aderência de Enterococcus faecalis e a ação desinfetante de compostos naturais e sintéticos foram verifcadas em 25 pinos de fibra de vidro. Os pinos foram submersos em 5 mL de suspensão de E. faecalis padronizada em 10 células/mL, incubados a 37ºC/1h e lavados em solução fisiológica e divididos em 5 grupos (n=5); sendo que o grupo controle (GI) não recebeu tratamento, e os outros grupos foram tratados com gluconato de clorexidrina 0,12% (GII); extrato etanólico de melaleuca 12% (GIII), álcool 70% (GIV) e extrato etanólico de própolis 12% (GV) por 5 minutos. Após lavagem e homogeneização dos pinos em 10 mL de solução fisiológica esterelizada por 30 segundos, alíquotas de 0,1 mL foram semeadas, em duplicata, em ágar Brain Heart Infusion e incubadas a 37ºC/24h. As médias e o desvio padrão obtidos do logaritmo 10 das unidades formadoras de colônia/mL (UFC/mL) de E. faecalis foram GI (5.16±0.11); GII (3.06±1.13); GIII (4.58±1.70); GIV (3.20±1.70); GV (1.85±1.99). O teste Kruskal-Wallis-Dunn demonstrou diferença estatisticamente significante (p<0.05) entre o grupo I e os grupos II, IV e V. A malaleuca (GIII) não apresentou ação desinfetante significante, porém os demais produtos tiveram ação desinfetante no controle da aderência bacteriana por apresentarem resultados semelhantes.

Enterococcus faecalis's ability to adhere and antibacterial effect of natural and synthetic compounds were studied in 25 glass fiber posts. The posts were submerged in 5 mL suspension of E. faecalis standardized in 10 cells/mL and incubated at 37ºC/1h. After wash in saline solution, they were divided into 5 groups (n = 5); while the control group (GI) received no treatment, the other groups were treated with chlorhexidine gluconate 0.12% (GII); ethanolic extract of melaleuca 12% (GIII), alcohol 70% (GIV) and ethanolic extract of propolis 12% (GV) for 5 minutes each. The posts were washed in saline solution for 30 seconds, aliquots of 0.1mL were plated in duplicate, on agar BHI and incubated at 37ºC/24h. Then, it was determined the number of CFU/mL E. faecalis recovered from each post. The average and standard deviation obtained from the logarithm of CFU/mL were GI (5.16±0.11); GII (3.06±1.13); GIII (4.58±1.70); GIV (3.20±1.70); GV (1.85±1.99). The Kruskal-Wallis-Dunn test showed statistically significant difference (p<0.05) between group I and groups II, IV and V. Melaleuca (GIII) presented no significant antibacterial action, but the others products may be used successfully to control bacterial adherence in fiber posts.
Descritores: Desinfecção
Enterococcus faecalis
Microbiologia
Pinos Dentários
Tipo de Publ: Estudo de Avaliação
Responsável: BR310.1 - Biblioteca Professor Guilherme Simões Gomes


  8 / 309 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-536675
Autor: Nunes, Thais; Perrone, Luciana; Fontes, Silvia Terra; Pinto, Márcia Bueno.
Título: Frequencia de pinos intrarradiculares utilizados em procedimentos de reconstrução dentária na Faculdade de Odontologia da Universidade Federal de Pelotas / Frequence of posts used in dental reconstruction procedures in the patients assisted at Dentistry School of Federal University of Pelotas
Fonte: Odontol. clín.-cient;8(4):315-318, out.-dez.2009. tab, graf.
Idioma: pt.
Resumo: Objetivo: Realizar um levantamento dos pinos intracanais utilizados nos procedimentos de reconstrução dentária, na Faculdade de Odontologia da Universidade Federal de Pelotas, e verificar sua relação com a técnica restauradora e localização no arco dentário. Metodologia: Os prontuários arquivados no Serviço de Triagem, no período entre 2005 e 2008, foram analisados quanto ao tipo de pino intracanal, técnica restauradora e localização no arco dentário. Os dados foram analisados estatisticamente (teste Qui-quadrado), considerando p < 0,05. Resultados: De um total de 5.566 registros, 192 (4,7%) procedimentos restauradores utilizaram os seguintes tipos de retontores: 107 (55.7%) metálicos fundidos, 38 (19,7%) fibra de vidro, 27 (14,1%) metálicos, 14 (7,2%) fibra de carbono e 6 (3,1%) fio de aço. Restaurações indiretas e diretas foram realizadas em 51% e 49% dos casos, respectivamente. Pinos metálicos fundidos foram mais associados a restaurações indiretas (p < 0,001). Considerando a sua localização na arcada, não houve diferença significativa entre os pinos utilizados na região anterior e posterior (p = 0,457).Conclusões: Durante o período de estudo, a maioria dos procedimentos de reconstrução dentária em dentes tratados endodonticamente foram realizados sem utilização de retentores intracanais. Porém, pinos metálicos fundidos foram mais frequentemente associados a coroas unitárias protéticas.

Purpose: To accomplish a rising of posts used in dental reconstruction procedures, at the School of Dentistry of Federal University of Pelotas, and verify it relationship with the restoring technique and location in the dental arch.Methods: The handbooks filed in the Service of Patient Selection, in the period understood between 2005 and 2008, it were appreised as for the post type, recovering technique and location in the dental arch. The data were submitted to the statistical analysis (test Qui-square), considering p<0,05. Results: From the total of 5.566 handbooks filed, 192 (4,7%) recovering procedures were accomplished using the following types of posts: 107 (55,7%) melted metallic, 38 (19,7%) glass fiber, 27 (14,1%) metallic, 14 (7,2%) carbon fiber and 6 (3,1%) posts of steel. Prosthetic crowns (indirects) and direct recovering were accomplished in 51% and 36,9% of the cases, respectively. Melted metallic posts were more associated to indirect restorations (p<0,001) . Considering the position of the tooth in the arcade, there was not statistic significant differences among the types of posts used in the anterior and posterior area (p=0,457). Conclusions: During the period of this study, the majority of recovering procedures of endodontically treated teeth was accomplished without the use of posts. However, melted metallic posts were more associated to indirect restorations.
Descritores: Pinos Dentários
Restauração Dentária Permanente
Restauração Dentária Temporária
Responsável: BR310.1 - Biblioteca Professor Guilherme Simões Gomes


  9 / 309 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-698338
Autor: Gusmão, João Milton Rocha; Pereira, Renato Piai; Alves, Guilhermino Oliveira; Pithon, Matheus Melo; Moreira, David Costa.
Título: Adaptação de pino/núcleos metálicos fundidos modelados com diferentes resinas acrílicas / Adjustment of cast metal post/cores modeled with diferente acylic resins
Fonte: Arq. odontol;49(1):6-11, 2013. ilus.
Idioma: en.
Resumo: Aim: Evaluate the performance of four commercially available chemically-activated acrylic resins (CAARs) by measuring the level of displacement of the cores following casting. Materials and Methods: Two devices were constructed to model the cores based on a natural tooth. Forty post/cores were modeled, 10 in each of the following CAARs: Duralay (Reliance Dental, Illinois, USA), Pattern Resin (GC, Tokyo, Japan), Dencrilay (Dencril, Sao Paulo, Brazil), and Jet (Clássico, Sao Paulo, Brazil). Two casting rings were included, each of which contained 5 post/cores for each of the four CAARs tested, a total of 20 per ring. Following casting, the specimens were only sandblasted and separated from the feeding channels. The post/cores were placed in device 1 and, with the aid of an optical microscope, were attached to a digital camera. Images were then taken of the adjustment between the core and the remaining tooth on the labial surface. The images were processed using the Image Tool for Windows, version 3.0, measuring three fixed points in each specimen. Data were statistically analyzed using the ANOVA and Tukey test. Results: The 40 post/cores were divided into eight groups according to resin brand and casting, obtaining the following results for mean and standard deviation (in mm): Dencrilay 0.192 CI (± 0.08), CII 0.058 (± 0.03); Duralay CI 0.097 (± 0.03), CII 0.131 (± 0.06); Pattern CI 0.07 (± 0.03), CII 0.10 (± 0.05); and Jet CI 0.06 (± 0.02), CII 0.382 (± 0.17). Statistically significant differences could be identified when comparing the Dencrilay CI and the Jet CII with the remaining groups, which all proved to be unfavorable. Conclusion: The quality of cast metal post/core adjustment is not associated with the use of a specific acrylic resin.
Descritores: Resinas Acrílicas/análise
Técnica para Retentor Intrarradicular/tendências
-/estatística & dados numéricos
AVALIACAO/estatística & dados numéricos
Pinos Dentários/estatística & dados numéricos
Responsável: BR365.1 - BIB - Biblioteca


  10 / 309 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-533401
Autor: Brito-Júnior, Manoel; Camilo, Carla Cristina; Soares, Janir Alves; Braga, Neilor Mateus Antunes.
Título: Os desgastes do núcleo e da linha de cimento maximizam a remoção ultra-sônica de pinos intra-radiculares fundidos / The wearing of the core and the cement line maximiza the ultrasonic removal of intraradicular cast posts
Fonte: Arq. odontol;43(3):67-72, jul.-set. 2007. ilus.
Idioma: pt.
Resumo: Neste estudo in vitro avaliou-se a influência dos desgastes do núcleo e da linha de cimento na remoção ultra-sônica de retentores intra-radiculares metálicos fundidos. Foram utilizados vinte e quatro pré-molares humanos, unirradiculares, que tiveram suas coroas removidas mantendo um remanescente radicular de 15mm. Os canais radiculares foram tratados endodonticamente, sendo preparados espaços para pinos com 9mm de profundidade, que foram moldados para obtenção dos retentores. Após fundição, os pinos foram cimentados com fosfato de zinco (SS White) e o conjunto raiz/pino fixado em tubos de PVC com 0,5 polegada de diâmetro e 3 cm de altura, contendo resina autopolimerizável. Decorridos 7 dias, a amostra foi distribuída aleatoriamente em 2 grupos (n=12): G1- desgastes dos núcleos e linha de cimento + ultra-som, e G2-apenas ultra-som. No G1 realizou-se os desgastes com a broca #1557, circunferencialmente aos núcleos e em seguida na linha cervical do cimento, com uma ponta diamantada cônica #3203 (KG Sorensen), numa profundidade de 2mm. O aparelho Enac (Osada, Japão) em potência máxima, com a ponta ST 09, foi aplicado em todas as faces dos núcleos, registrando-se o tempo até o completo deslocamento dos pinos. Para análise estatística utilizou-se o teste t-Student (p<0,05). Verificou-se que a média de tempo para G1 e G2 foi de 48,4 e 99,4 segundos, respectivamente, com diferença significatica entre os grupos (p=0,036). Portanto, os desgastes do núcleo e da linha de cimento diminuíram, de forma significativa, o tempo de vibração ultra-sônica na remoção de retentores intra-radiculares cimentados com fosfato de zinco.
Descritores: Técnica para Retentor Intrarradicular
Dente não Vital
-Compômeros
Interpretação Estatística de Dados
Pinos Dentários
Responsável: BR365.1 - BIB - Biblioteca



página 1 de 31 ir para página                         
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde