Base de dados : LILACS
Pesquisa : E06.780.250 [Categoria DeCS]
Referências encontradas : 180 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 18 ir para página                         

  1 / 180 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-840194
Autor: Souki, Marcelo Quiroga.
Título: Severe Angle Class III skeletal malocclusion associated to mandibular prognathism: orthodontic-surgical treatment
Fonte: Dental press j. orthod. (Impr.);21(6):103-114, Sept.-Oct. 2016. tab, graf.
Idioma: en.
Resumo: ABSTRACT The present case report describes the orthodontic treatment of a young adult patient (18y / 1m), Class III skeletal malocclusion, with mandibular prognathism and significant dental compensation. The canine relation was Class III, incisors with tendency to crossbite and open bite, moderate inferior crowding, and concave profile. Skeletal correction of malocclusion, facial profile harmony with satisfactory labial relationship, correction of tooth compensation and normal occlusal relationship were obtained with orthodontic treatment associated to orthognathic surgery. This case was presented to the Brazilian Board of Orthodontics and Facial Orthopedics (BBO), as part of the requirements to become a BBO diplomate.

RESUMO O presente caso clínico descreve o tratamento ortodôntico de um paciente com 18 anos e 1 mês de idade, portador de má oclusão esquelética de Classe III, com prognatismo mandibular e significativa compensação dentária. A relação entre caninos era de Classe III, incisivos com tendência à mordida cruzada e mordida aberta, moderado apinhamento inferior, além de perfil côncavo. A correção esquelética da má oclusão; a harmonia do perfil facial, com relação labial satisfatória; correção da compensação dentária e relação oclusal normal foram obtidas com o tratamento ortodôntico associado à cirurgia ortognática. Esse caso foi apresentado à Diretoria do Board Brasileiro de Ortodontia e Ortopedia Facial (BBO), como parte dos requisitos para a obtenção do título de Diplomado pelo BBO.
Descritores: Má Oclusão Classe III de Angle/terapia
-Ortodontia Corretiva/métodos
Radiografia Dentária
Radiografia Panorâmica
Técnica de Fundição Odontológica
Braquetes Ortodônticos
Má Oclusão Classe III de Angle/cirurgia
Má Oclusão Classe III de Angle/diagnóstico
Má Oclusão Classe III de Angle/patologia
Limites: Humanos
Masculino
Adolescente
Tipo de Publ: Relatos de Casos
Responsável: BR1.1 - BIREME


  2 / 180 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-891110
Autor: Janson, Guilherme; Maranhão, Olga Benário Vieira.
Título: Compensatory Class III malocclusion treatment associated with mandibular canine extractions
Fonte: Dental press j. orthod. (Impr.);22(6):86-98, Nov.-Dec. 2017. tab, graf.
Idioma: en.
Resumo: ABSTRACT Skeletal Class III malocclusions are ideally treated with orthodontic-surgical approaches. However, if there are no significant soft tissue implications and the patient does not want to undergo orthognatic surgery, other treatment options may be considered. The current case report describes a compensatory alternative for Class III malocclusion treatment, by means of mandibular canine extractions. This treatment alternative provided facial profile and occlusal improvement, which remains stable seven years posttreatment.

RESUMO As más oclusões esqueléticas de Classe III são idealmente tratadas com intervenções ortodôntico-cirúrgicas. Contudo, se não existirem implicações estéticas faciais e se o paciente não desejar se submeter à cirurgia ortognática, outras opções de tratamento podem ser consideradas. O presente caso clínico descreve um tratamento compensatório alternativo para a má oclusão de Classe III, com extrações de caninos inferiores. Esse tratamento alternativo propiciou melhoras no perfil facial e na oclusão, que permaneceu estável após sete anos da sua finalização.
Descritores: Ortodontia Corretiva/métodos
Extração Dentária
Dente Canino/cirurgia
Má Oclusão Classe III de Angle/cirurgia
Má Oclusão Classe III de Angle/terapia
Mandíbula/cirurgia
-Ortodontia Corretiva/instrumentação
Planejamento de Assistência ao Paciente
Radiografia Panorâmica
Cefalometria
Técnica de Fundição Odontológica
Técnica de Expansão Palatina
Resultado do Tratamento
Braquetes Ortodônticos
Aparelhos de Tração Extrabucal
Assimetria Facial/complicações
Assimetria Facial/terapia
Má Oclusão Classe III de Angle/diagnóstico por imagem
Mandíbula/diagnóstico por imagem
Limites: Humanos
Feminino
Adolescente
Tipo de Publ: Relatos de Casos
Responsável: BR1.1 - BIREME


  3 / 180 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-975020
Autor: Nojima, Lincoln Issamu; Nojima, Matilde da Cunha Gonçalves; Cunha, Amanda Carneiro da; Guss, Natan Oliveira; Sant'Anna, Eduardo Franzotti.
Título: Mini-implant selection protocol applied to MARPE
Fonte: Dental press j. orthod. (Impr.);23(5):93-101, Sept.-Oct. 2018. graf.
Idioma: en.
Resumo: Abstract Introduction: Rapid maxillary expansion (RME) is the therapy of choice to correct skeletal transverse dimension in children and adolescents, associating orthopedic and dental effects. In an attempt to prevent the undesirable dentoalveolar effects and optimize the potential of skeletal expansion in individuals in advanced stages of skeletal maturation, the miniscrew-assisted rapid palatal expander (MARPE) was proposed by Lee et al. in 2010. Objective: This paper presents a systematized protocol for selection of miniscrews indicated for MARPE, by the evaluation of cone-beam computed tomographies (CBCT). Variables related with the bone and soft tissue thicknesses at the palatal regions of interest, as well as in relation to the fixation rings of miniscrews of the palatal expander are analyzed and discussed to provide better performance in the clinical practice.

Resumo Introdução: a expansão rápida da maxila (ERM) é a terapia de escolha para a correção da dimensão transversa esquelética em crianças e adolescentes, associando-se efeitos ortopédicos e dentários. Com a finalidade de prevenir os efeitos dentoalveolares indesejáveis e otimizar o potencial de expansão esquelética em indivíduos com estágios avançados de maturação esquelética, a técnica de expansão rápida da maxila assistida por mini-implantes (MARPE) foi proposta por Lee e colaboradores em 2010. Objetivo: o presente estudo apresenta um protocolo sistematizado para seleção de mini-implantes indicados para a MARPE, mediante avaliação de imagens de tomografia computadorizada de feixe cônico (TCFC). Variáveis relacionadas à espessura de tecido ósseo e tecido mole nas regiões de interesse do palato, bem como em relação ao anel de fixação dos mini-implantes do parafuso expansor, são analisadas e discutidas para proporcionar melhor desempenho na prática clínica.
Descritores: Parafusos Ósseos
Técnica de Expansão Palatina/instrumentação
Procedimentos de Ancoragem Ortodôntica/métodos
Má Oclusão/terapia
-Protocolos Clínicos
Técnica de Fundição Odontológica
Implantação Dentária/instrumentação
Implantação Dentária/métodos
Procedimentos de Ancoragem Ortodôntica/instrumentação
Tomografia Computadorizada de Feixe Cônico
Má Oclusão/diagnóstico por imagem
Limites: Humanos
Responsável: BR1.1 - BIREME


  4 / 180 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-1135482
Autor: Ahliya, Syifa; Hartomo, Bambang Tri; Adrianto, Angger Waspodo Dias; Sarwono, Agoeng Tjahajani; Auerkari, Elza Ibrahim.
Título: Sex Identification Based on Tooth Crown Trait Analysis Among the Mongoloid Race
Fonte: Pesqui. bras. odontopediatria clín. integr;20:e5681, 2020. tab.
Idioma: en.
Projeto: Universitas Indonesia Research Grant.
Resumo: Abstract Objective: To determine whether anterior and posterior tooth crown traits exhibit sexual dimorphism and identify traits characteristic to the Mongoloid race, especially among the Indonesian population. Material and Methods: This study cross-sectional study analyzed 108 dental casts from 36 males and 72 females. The traits analyzed included winging, shoveling, double shoveling, canine mesial ridge, canine distal accessory ridge, hypocone, metaconule, Carabelli's cusp, protostylid, metaconulid, enteconulid, and hypoconulid. All tooth crown traits were scored based on the ASUDAS scoring system. Descriptive statistics were used to calculate the absolute and relative frequencies. The Chi-square tests was used to determine significant differences in anterior and posterior tooth crown traits between males and females. Level of significance was set at 5%. Results: None of the traits showed sexual dimorphism. Moreover, the most common traits among the Mongoloid race were hypocone (94.4%) and shoveling (86.1%). Conclusion: Although none of the traits exhibited sexual dimorphism, most of them had a higher incidence among females than males. Nonetheless, further research including adequate samples and a similar number of females and males, is needed, especially for population studies.
Descritores: Técnica de Fundição Odontológica/instrumentação
Antropologia Forense/legislação & jurisprudência
Coroa do Dente/anatomia & histologia
Grupo com Ancestrais do Continente Asiático
Odontologia Legal/legislação & jurisprudência
-Distribuição de Qui-Quadrado
Estudos Transversais/métodos
Indonésia/epidemiologia
Limites: Humanos
Masculino
Feminino
Criança
Adolescente
Adulto
Pessoa de Meia-Idade
Tipo de Publ: Estudo Comparativo
Responsável: BR1264.1 - Biblioteca Setorial Prof Alberto M Campos


  5 / 180 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-568231
Autor: Manrique Guzmán, Jorge A; Chávez Reátegui, Beatriz del C.
Título: Adaptación del colado en prótesis fija y removible en pacientes de la clínica odontológica de la UNFV / Adjustment of the cast in fixed and removable prosthesis in patients of the dental clinic of National University Federico Villarreal
Fonte: Rev. estomatol. Hered;20(3):137-141, jul.-sept. 2010. tab.
Idioma: es.
Resumo: El presente estudio, fue diseñado para identificar la frecuencia de adaptación de los colados en prótesis fija y removible en pacientes de la clínica odontológica de la Universidad Nacional Federico Villarreal, tomando como muestra 100 trabajos que ingresaron al laboratorio de la facultad, el 38% fueron prótesis parcial re movible de cromo cobalto y el 62% prótesis fija. De esta muestra, el 78% de las prótesis parciales removibles, requirieron desgastes internos para su adaptación, ya sea de los ganchos, retenedores y/o opositores como de los apoyos, el 10% se debió repetir y tan solo el 12% adaptó sin ningún tipo de desgate, de las prótesis fijas, en promedio, el 80% debió recibir: algún tipo de desgaste para su adaptación y un 18% debió de repetirse, mientras que tan solo un 2% no requirió de ningún tipo de desgaste. Estos resultados nos indican una alta frecuencia de errores y fallas en los colados que repercuten directamente en la eficiencia y calidad del servicio.

This study was designed to identify the frequency of adjustment of the cast in fixed and removable prosthesis in patients in the dental clinic of National University Federico Villarreal, taking a sample of 100 models that were sent to the laboratory of the dental school, 38% were removable partial dentures cobalt chromium and 62% fixed prosthesis. From this sample, 78% of the removable partial dentures, required trimming for their adaptation, either of the retaining the hooks and/or opponents of support, 10% was due to repeat and only 12% adjusted without any wear rate of fixed prostheses, on average, 80% had received some type of trimming for adaptation and 18% had to be repeated, while only 2% did not require any kind of trimming. These results indicate a high frequency of errors and mistakes in the cast that directly affect the efficiency and quality of service.
Descritores: Prótese Parcial Fixa
Prótese Parcial Removível
Oclusão Dentária
Técnica de Fundição Odontológica
-Peru
Universidades
Limites: Humanos
Masculino
Feminino
Responsável: PE1.1 - Oficina Universitária de Biblioteca


  6 / 180 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Texto completo
Id: biblio-998200
Autor: Bhatnagar, Akash; Jindal, Mahendra Kumar; Khan, Saima Yunus.
Título: Comparison of Two Different Non-Radiographic Mixed Dentition Analysis
Fonte: Pesqui. bras. odontopediatria clín. integr;19(1):4374, 01 Fevereiro 2019. tab, graf.
Idioma: en.
Resumo: Objective: To evaluate the applicability of two different non-radiographic mixed dentition analysis in school going children of Aligarh district, India. Material and Methods: Mesiodistal dimension was measured on the dental casts of 120 school going children with electronic digital vernier caliper. The following inclusion criteria were adopted: presence of all fully erupted permanent teeth; no congenital craniofacial anomalies; no previous history of orthodontic treatment; and presence of intact dentition with no proximal caries, restoration, or age related attrition. Predicted values of canines and premolars were obtained from Moyer's at 75th percentile and Tanaka and Johnston mixed dentition analysis. Descriptive statistics were used to calculate the mean and standard deviation. Paired observations were compared by t­test. The level of significance was at p<0.001. Results: The mean difference between the predicted and the actual value of canines and premolars using Moyer's probability table at 75th percentile and Tanaka and Johnston regression equation were statistically significant. No significant differences were found between Moyer's analysis 75th percentile and Tanaka and Johnston mixed dentition analysis in both arch and sexes. Conclusion: These two non-radiographic mixed dentition analysis overestimated the mesiodistal width of canines and premolars.
Descritores: Ortodontia
Técnica de Fundição Odontológica
Dentição Mista
Índia
Odontometria/métodos
-Dente Pré-Molar
Estudo Comparativo
Estudos Transversais/métodos
Estatísticas não Paramétricas
Dente Canino
Limites: Humanos
Masculino
Feminino
Criança
Adolescente
Tipo de Publ: Estudo Comparativo
Estudo de Avaliação
Responsável: BR1264.1 - Biblioteca Setorial Prof Alberto M Campos


  7 / 180 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-392460
Autor: Costa, Elza Maria Valadares da; Neisser, Maximiliano Piero; Bottino, Marco Antônio.
Título: Multiple-unit implant frames: one-piece casting vs. laser welding and brazing / Sobre estruturas de implantes múltiplos: fundição em monobloco versus soldagem a laser e brasagem
Fonte: J. appl. oral sci;12(3):227-231, July-Sept. 2004. ilus, tab, graf.
Idioma: en.
Resumo: A distorção linear das próteses sobre implantes, fundidas em monobloco e fundidas em secções e soldadas a laser e por brasagem foi avaliada em um modelo de uma mandíbula edêntula com cinco análogos de pilares de implantes, paralelos entre si com distância de 10mm medidos de centro a centro. Sobre estes foram parafusados novos cilindros de ouro, com torque de 10N/cm. Então foram executadas 15 sobre-estruturas metálicas que foram divididas: GC - Adaptação passiva dos cilindros de ouro; GM - monobloco, GB - segmentos soldados por brasagem e, GL - segmentos soldados a laser. Observaram-se as estruturas fixadas com parafusos novos sob microscópio de mensuração. A medição foi realizada na vestibular direita e esquerda e da mesma forma na lingual da interface cilindro/análogo e dados anotados em tabela apropriada. Para o eixo y, a técnica de soldagem a laser (Média=12,41 e Dp=11,12) produziu menos distorção significativamente do que a técnica de brasagem (Média=23,06 e Dp=21,88) seguida pela técnica de monobloco (Média=39,83 e Dp=21,88) p=0.05. Para o eixo x, somente o grupo Monobloco apresentou diferença significativa para as demais técnicas (Média=45,66 e Dp=21,56).
Descritores: Implantação Dentária Endo-Óssea
Implantação Dentária/instrumentação
Prótese Dentária Fixada por Implante
Técnica de Fundição Odontológica
-Próteses e Implantes
Implantes Dentários
Soldagem em Odontologia
Responsável: BR28.1 - Serviço de Biblioteca e Documentação Professor Doutor Antônio Gabriel Atta


  8 / 180 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Turssi, Cecília Pedroso
Id: biblio-877279
Autor: Alves, Marcus Bravo; Gehrke, Sérgio Alexandre; Turssi, Cecília Pedroso; Souza, Samilly Evangelista; Miranda, Milton Edson.
Título: Resistência à tração uniaxial de copings fundidos e cimentados sobre munhões cone-morse com diferentes diâmetros e alturas / Uniaxial tensile strength of cast cemented copings for cone-morse prosthetic implant abutments with different diameters and heights
Fonte: ImplantNewsPerio;2(5):861-866, set.-out. 2017. ilus, tab.
Idioma: pt.
Resumo: Objetivo: avaliar a resistência à tração de copings fundidos cimentados sobre pilares cone-morse com diferentes alturas e diâmetros. Material e métodos: quatro grupos (G1: 3,5 mm x 4 mm; G2: 3,5 mm x 6 mm; G3: 4,5 mm x 4 mm; e G4: 4,5 mm x 6 mm) com cinco amostras cada tiveram seus copings encerados, fundidos (liga de Ni-Cr) e cimentados (Panavia F, carga de 6 Kfg durante cinco minutos) sobre os respectivos pilares já torqueados com 25 Ncm. Depois, as amostras foram imersas em água destilada a 37oC ± 2oC durante 24 horas e submetidas ao ensaio de tração até soltura das restaurações. Os dados obtidos foram analisados estatisticamente quanto ao atendimento das pressuposições de normalidade e de homogeneidade de variância, pelos testes de Shapiro-Wilk, Levene e Anova dois critérios (α=5%). Resultados: os valores (média ± desvio-padrão) de resistência à tração (em Newtons) foram: G1: 108,9 ± 37,2; G2: 168,6 ± 43,9; G3: 143,4 ± 57,1; G4: 236,8 ± 52,2. Não houve interação estatisticamente significativa entre as variáveis diâmetro e altura (p=0,446). Ao se comparar os valores de resistência à tração, notou-se efeitos estatisticamente significativos entre o diâmetro (p=0,030) e a altura (p=0,003) dos munhões cone-morse. Munhões com 4,5 mm de diâmetro proporcionaram resistência à tração significativamente superior àquela obtida na condição em que foram empregados munhões com 3,5 mm, tanto nas condições 4 mm quanto 6 mm de altura. A resistência à tração foi aumentada (37%) com munhões 4,5 mm comparados aos munhões 3,5 mm. A resistência à tração foi aumentada (60,7%) com a altura de 6 mm, comparada à altura de 4 mm. Conclusão: pilares para implantes cone-morse com maiores dimensões proporcionam maior segurança e estabilidade às coroas cimentadas sobre implantes.

Objective: to evaluate the tensile strength of cemented copings on cone-morse abutments with different heights and diameters. Material and methods: four groups (G1: 3.5 mm x 4 mm; G2: 3.5 mm x 6 mm; G3: 4.5 mm x 4 mm; and G4: 4.5 mm x 6 mm) with five samples each had their waxed copings and cast in Ni-Cr alloy, being cemented (Panavia F, 6 Kgf-load, 5 minutes) on their respective already torqued abutments (25 Ncm). Then, samples were immersed in distilled water (37oC ± 2oC) for 24 hours and subjected to the tensile test until restorations being separated. The data obtained were analyzed statistically for normality and homogeneity of variances by the Shapiro-Wilk and Levene tests. Comparisons were made using the 2-way Anova test (α=5%). Results: the values (mean ± standard deviation) of tensile strength (in Newtons) were: G1: 108.9 ± 37.2; G2: 168.6 ± 43.9; G3: 143.4 ± 57.1; G4: 236.8 ± 52.2. There was no statistically significant interaction between the variables diameter and height (p=0.446). When comparing values of tensile strength, we observed statistically significant effects for diameter (p=0.030) and height (p=0.003). Abutments with a 4.5 mm diameter provide significantly higher tensile strength to those obtained with 3.5 mm in both 4 mm and 6 mm height conditions. The tensile strength was increased (37%) for the 4.5 mm compared to the 3.5 mm condition. The tensile strength was increased (60.7%) with a height of 6 mm, compared to height of 4 mm. Conclusion: abutments for cone-morse implants with larger dimensions provide greater safety and stability for cemented crowns.
Descritores: Interpretação Estatística de Dados
Técnica de Fundição Odontológica
Implantação Dentária
Osseointegração
Resistência à Tração
Limites: Humanos
Tipo de Publ: Estudo de Avaliação
Responsável: BR510.1 - Biblioteca Central


  9 / 180 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Silva, Eulália Maria Martins da
Texto completo
Id: biblio-874124
Autor: Marchiori, André Vinícius; Silva, Eulália Maria Martins da; Zequetto, Michele Marques.
Título: Efeito das técnicas de inclusão convencional e rápida sobre a resistência ao impacto de revestimentos odontológicos / Effect of the conventional and fast inclusion techniques on the impact strength of dental investments
Fonte: RGO (Porto Alegre);58(2):161-166, abr.-jun. 2010. tab, graf, ilus.
Idioma: pt.
Resumo: Objetivo: Comparar a resistência ao impacto de revestimentos submetidos a duas diferentes técnicas de inclusão. Métodos: Foram utilizados quatro revestimentos (All Therm - R1; Flash - R2, Heat Shock - R3 e Micro Fine - R4) em duas diferentes técnicas de inclusão (Convencional - T1 ou Rápida - T2). Os corpos-de-prova de cada grupo (n=15) foram obtidos por meio de uma matriz de silicone (70mmx12mmx12mm), vazando-se os revestimentos proporcionados e manipulados conforme as recomendações dos fabricantes. Após aquecimento em forno, foram submetidos ao teste de resistência ao impacto, com potência de trabalho de 40Kpcm, correspondente a 3,94J. Resultados: Em ordem decrescente de valores de resistência ao impacto (kJ/m2), os grupos se distribuíram da seguinte forma: R3T1 (1,34±0,11); R3T2 (1,22±0,07); R4T2 (1,21±0,09); R2T1 (1,16±0,10); R4T1 (1,16±0,07); R1T2 (1,12±0,07); R2T2 (1,12±0,08) e R1T1 (1,09±0,10). Nenhum grupo apresentou valor significantemente diferente (p>0,05) quanto ao fator técnica. Entre os grupos T1 só R3 diferiu dos demais revestimentos e entre os grupos T2, R3 e R4 apresentaram maiores valores. Conclusão: As diferentes técnicas de inclusão não exerceram influência sobre a resistência ao impacto dos revestimentos testados.

Objective: Compare the impact strength of investments submitted to two different investing techniques. Methods: Four investments were used (All Therm - R1; Flash - R2, Heat Shock - R3 and Micro Fine - R4) in two different investing techniques (Conventional - T1 or Accelerated - T2). Each group sample (n=15) was obtained by means of a silicone die (70mmx12mmx12mm), and the investments were poured according to the manufacturer´s instructions. After heating in an oven, the samples were submitted to the impact test with an impact load of 40Kpcm, corresponding to 3.94J. Results: The following impact strength values were obtained (kJ/m2) in decreasing order: R3T1 (1.348±0.116); R3T2 (1.221±0.075); R4T2 (1.217±0.096); R2T1 (1.162±0.101); R4T1 (1.162±0.075); R1T2 (1.126±0.077); R2T2 (1.126±0.085) and R1T1 (1.099±0.106). No group presented a significantly different value (p>.05) with regard to technique. Among the T1 groups, only R3 differed from the other investments and among the T2 groups, R3 and R4 presented higher values. Conclusion: Different investing techniques did not influence the impact strength of the tested investments.
Descritores: Revestimento para Fundição Odontológica
Técnica de Fundição Odontológica
Materiais Dentários
Resistência de Materiais
Tipo de Publ: Estudo Comparativo
Responsável: BR1354.1 - Biblioteca São Leopoldo Mandic


  10 / 180 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Assunçäo, Wirley Gonçalves
Id: biblio-873787
Autor: Zaquetto, Michele Marques; Silva, Eulália Maria Martins; Zuim, Paulo Renato Junqueira; Rocha, Eduardo Passos; Assunção, Wirley Gonçalves.
Título: Falhas no processo de fundição que levam ao insucesso das Próteses Parciais Fixas / Poor casting that cause Partial fixed Dentures failure
Fonte: Rev. bras. odontol;62(3/4):230-233, 2005.
Idioma: pt.
Resumo: Nosso objetivo foi verificar quais fatores nos processos de fundição e soldagem estão relacionados com a ocorrência de falhas que podem determinar insucessos das Próteses Parciais Fixas após sua instalação. Através de revisão bibliográfica podemos constatar que muitas falhas ocorrem por inabilidade ou descuido do operador, durante as etapas que precedem e envolvem a fundição, e pela falta de conhecimento sobre as propriedades e limitações que os materiais utilizados apresentam. Apesar de simples e rotineiro nos laboratórios de prótese dentária, o processo de fundição deve prosseguir com rigor para que as peças metálicas obtidas tenham precisão, sejam adaptadas e resistentes.
Descritores: Técnica de Fundição Odontológica
Soldagem em Odontologia
Prótese Parcial Fixa
-Literatura de Revisão como Assunto
Responsável: BR485.1 - Biblioteca Mário Badan



página 1 de 18 ir para página                         
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde