Base de dados : LILACS
Pesquisa : E07.132.125 [Categoria DeCS]
Referências encontradas : 26 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 3 ir para página          

  1 / 26 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-977992
Autor: Plotnikow, Gustavo A; Vasquez, Daniela; Pratto, Romina; Carreras, Lucia.
Título: Oxigenoterapia a alto flujo con cánula nasal en el tratamiento de la falla respiratoria aguda hipoxémica en una paciente embarazada: reporte de un caso / High-flow nasal cannula in the treatment of acute hypoxemic respiratory failure in a pregnant patient: case report
Fonte: Rev. bras. ter. intensiva;30(4):508-511, out.-dez. 2018. graf.
Idioma: es.
Resumo: RESUMEN Existe poca evidencia que avale el uso de ventilación mecánica no invasiva en falla respiratoria aguda hipoxémica. Sin embargo, considerando las complicaciones asociadas a la intubación endotraqueal, se intentó implementar ventilación mecánica no invasiva en una paciente de 24 años cursando 32 semanas de gestación, que ingresó a la unidad de cuidados intensivos con falla respiratoria aguda hipoxémica y sepsis a foco urinario. La falta de tolerancia a la ventilación mecánica no invasiva, nos indujo a utilizar un método alternativo con el fin de evitar la intubación endotraqueal. La implementación de terapia con oxígeno a alto flujo a través de cánula nasal permitió superar la situación, presentando a ésta técnica como una opción de tratamiento en pacientes obstétricas críticas, segura tanto para la madre como para el feto.

ABSTRACT Little evidence exists to support the use of noninvasive mechanical ventilation for acute hypoxemic respiratory failure. However, considering the complications associated with endotracheal intubation, we attempted to implement noninvasive mechanical ventilation in a 24-year-old patient who was 32 weeks pregnant and was admitted to the intensive care unit with acute hypoxemic respiratory failure and sepsis secondary to a urinary tract infection. Lack of tolerance to noninvasive mechanical ventilation led us to use an alternative method to avoid endotracheal intubation. The use of high-flow nasal cannula allowed to overcome this situation, wich supports this technique as a treatment option for critical obstetric patients that is safe for both the mother and fetus.
Descritores: Complicações na Gravidez/terapia
Síndrome do Desconforto Respiratório do Adulto/terapia
Ventilação não Invasiva/métodos
Cânula
-Complicações na Gravidez/fisiopatologia
Infecções Urinárias/complicações
Sepse/etiologia
Sepse/terapia
Unidades de Terapia Intensiva
Limites: Humanos
Feminino
Gravidez
Adulto Jovem
Tipo de Publ: Relatos de Casos
Responsável: BR1.1 - BIREME


  2 / 26 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-977990
Autor: Bocchile, Rafael Ladeira Rosa; Cazati, Denise Carnieli; Timenetsky, Karina Tavares; Serpa Neto, Ary.
Título: Efeitos do uso de cateter nasal de alto fluxo na intubação e na reintubação de pacientes críticos: revisão sistemática, metanálise e análise de sequência de ensaios / The effects of high-flow nasal cannula on intubation and re-intubation in critically ill patients: a systematic review, meta-analysis and trial sequential analysis
Fonte: Rev. bras. ter. intensiva;30(4):487-495, out.-dez. 2018. tab, graf.
Idioma: pt.
Resumo: RESUMO Objetivo: Avaliar a eficácia do cateter nasal de alto fluxo na prevenção de intubação e reintubação de pacientes críticos em comparação com oxigenoterapia convencional ou ventilação não invasiva. Métodos: Esta revisão sistemática foi realizada por meio de busca eletrônica em bancos de dados incluindo trabalhos publicados entre 1966 e abril de 2018. O desfecho primário foi a necessidade de intubação ou reintubação. Os desfechos secundários foram escalonamento de terapia, mortalidade no seguimento mais longo, mortalidade hospitalar e necessidade de ventilação não invasiva. Resultados: Dezessete estudos com 3.978 pacientes foram incluídos. Não houve redução na necessidade de intubação ou reintubação (OR 0,72; IC95% 0,52 - 1,01; p = 0,056). Não houve diferença no escalonamento de terapia (OR 0,80; IC95% 0,59 - 1,08; p = 0,144), na mortalidade no seguimento mais longo (OR 0,94; IC95% 0,70 - 1,25; p = 0,667), na mortalidade hospitalar (OR 0,84; IC95% 0,56 - 1,26; p = 0,391) ou na necessidade de ventilação não invasiva (OR 0,64; IC95% 0,39 - 1,05, p = 0,075). Na análise sequencial de ensaios, o número de eventos incluídos foi menor que o tamanho ótimo de informação, com erro tipo I global > 0,05. Conclusão: No presente estudo e no cenário avaliado, o cateter nasal de alto fluxo não foi associado com redução na necessidade de intubação ou reintubação em pacientes críticos.

ABSTRACT Objective: To evaluate the efficacy of high-flow nasal cannula in the prevention of intubation and re-intubation in critically ill patients compared to conventional oxygen therapy or noninvasive ventilation. Methods: This systematic review was performed through an electronic database search of articles published from 1966 to April 2018. The primary outcome was the need for intubation or re-intubation. The secondary outcomes were therapy escalation, mortality at the longest follow-up, hospital mortality and the need for noninvasive ventilation. Results: Seventeen studies involving 3,978 patients were included. There was no reduction in the need for intubation or re-intubation with high-flow nasal cannula (OR 0.72; 95%CI 0.52 - 1.01; p = 0.056). There was no difference in the need for therapy escalation (OR 0.80, 95% CI 0.59 - 1.08, p = 0.144), mortality at the longest follow-up (OR 0.94; 95%CI 0.70 - 1.25; p = 0.667), hospital mortality (OR 0.84; 95%CI 0.56 - 1.26; p = 0.391) or noninvasive ventilation (OR 0.64, 95%CI 0.39 - 1.05, p = 0.075). In the trial sequential analysis, the number of events included was lower than the optimal information size with a global type I error > 0.05. Conclusion: In the present study and setting, high-flow nasal cannula was not associated with a reduction of the need for intubation or re-intubation in critically ill patients.
Descritores: Oxigenoterapia/métodos
Cânula
Intubação Intratraqueal/estatística & dados numéricos
-Mortalidade Hospitalar
Estado Terminal
Ventilação não Invasiva/métodos
Limites: Humanos
Tipo de Publ: Metanálise
Revisão Sistemática
Responsável: BR1.1 - BIREME


  3 / 26 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-668157
Autor: Wolfenson, Moisés; Roncatti, Claudio; Silva Júnior, Edvaldo Alfredo da.
Título: Quebra de ponta de cânula, no plano gorduroso, durante lipoaspiração / Breakage of the tip of the cannula in the adipose tissue during liposuction
Fonte: Rev. bras. cir. plást;27(3):490-492, jul.-set. 2012. ilus.
Idioma: en; pt.
Resumo: Durante procedimento de lipoaspiração, uma cânula teve seu segmento distal de 3 cm quebrado no plano adiposo. Os autores apresentam, neste trabalho, a conduta adotada para solução do caso, de maneira simples e rápida, com emprego de um intensificador de imagens, sem grandes dificuldades.

During liposuction, 3 cm of the distal segment of the cannula broke within the patient's adipose tissue. We used an image intensifier to easily and quickly address this complication without the development of any sequelae for the patient.
Descritores: Cirurgia Plástica
Lipectomia
Tecido Adiposo
Adipócitos
Falha de Equipamento
Cânula
-Cirurgia Plástica/métodos
Lipectomia/efeitos adversos
Lipectomia/métodos
Tecido Adiposo/cirurgia
Adipócitos/fisiologia
Cânula/efeitos adversos
Limites: Humanos
Feminino
Adulto
História do Século XXI
Tipo de Publ: Relatos de Casos
Responsável: BR32.1 - Serviço de Biblioteca e Informação Biomédica


  4 / 26 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-1088089
Autor: Zamorano W, Alejandra V; Méndez R, Mireya P.
Título: Bronquiolitis aguda: tratamiento de la insuficiencia respiratoria / Acute bronchiolitis: treatment of respiratory insufficiency
Fonte: Neumol. pediátr. (En línea);15(1):245-250, Mar. 2020. tab, ilus.
Idioma: es.
Resumo: The severe respiratory insufficiency (SRI) caused by acute bronchitis whose main etiology is the respiratory syncytial virus is the main cause of under 2-year-old children hospitalization during the winter months, especially in the risk groups. Its treatment is mainly based in general measures, administration of respiratory support with standard oxygen therapy, non-invasive ventilation, invasive mechanical ventilation or the emerging high flow nasal cannula therapy, which these past few years has become an easy alternative of use, well tolerated, secure to be used in emergency rooms, basic rooms and pediatric intensive care units. The election of therapy will depend of the patient severity, the level of complexity of the healthcare center and the experience in the different treatment modalities of the health team. It is essential to carry out protocols and guidelines for the management of SRI treatment caused by acute bronchitis for emergency services, basic rooms and pediatric intensive care.

La insuficiencia respiratoria aguda (IRA) causada por bronquiolitis aguda (BA), cuya principal etiología es el virus respiratorio sincicial (VRS), es la principal causa de hospitalizaciones en menores de 2 años durante los meses de invierno, especialmente en grupos de riesgo. Su manejo se basa principalmente en medidas generales, administración de soporte respiratorio con oxigenoterapia estándar, ventilación no invasiva (VNI), ventilación mecánica invasiva (VMI) o la emergente terapia con cánula nasal de alto flujo (CNAF), que se ha transformado en los últimos años en una alternativa de fácil uso, bien tolerada, segura para ser usada en los servicios de urgencia, salas básicas y unidades de cuidados intensivos pediátricos (UCIP). La elección de la terapia a utilizar dependerá de la gravedad del paciente, del nivel de complejidad del centro asistencial y de la experiencia en las distintas modalidades de tratamiento del equipo de salud. Es fundamental realizar protocolos y guías de manejo de tratamiento de la IRA causada por BA tanto para servicios de urgencia, salas básicas como cuidados intensivos pediátricos.
Descritores: Insuficiência Respiratória/etiologia
Insuficiência Respiratória/terapia
-Oxigenoterapia
Respiração Artificial/métodos
Bronquiolite Viral/complicações
Infecções por Vírus Respiratório Sincicial/complicações
Cânula
Limites: Humanos
Recém-Nascido
Lactente
Responsável: CL1.1 - Biblioteca Central


  5 / 26 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: biblio-1013763
Autor: Yuste, Maria Eugenia; Moreno, Olga; Narbona, Susana; Acosta, Fernando; Peñas, Luis; Colmenero, Manuel.
Título: Eficácia e segurança da oxigenoterapia com cânula nasal de alto fluxo na insuficiência respiratória hipercápnica moderada aguda / Efficacy and safety of high-flow nasal cannula oxygen therapy in moderate acute hypercapnic respiratory failure
Fonte: Rev. bras. ter. intensiva;31(2):156-163, abr.-jun. 2019. tab, graf.
Idioma: pt.
Resumo: RESUMO Objetivo: Avaliar a eficácia e a segurança da oxigenoterapia com uso de cânula nasal de alto fluxo no tratamento da insuficiência respiratória hipercápnica moderada em pacientes que não conseguem tolerar ou têm contraindicações para ventilação mecânica não invasiva. Métodos: Estudo prospectivo observacional de 13 meses envolvendo participantes admitidos a uma unidade de terapia intensiva com insuficiência respiratória hipercápnica ou durante o processo de seu desenvolvimento. Os parâmetros clínicos e de troca gasosa foram registrados em intervalos regulares durante as primeiras 24 horas. Os parâmetros finais foram saturação de oxigênio entre 88 e 92%, juntamente da redução do esforço respiratório (frequência respiratória) e da normalização do pH (≥ 7,35). Os participantes foram considerados não responsivos em caso de necessidade de utilização de suporte ventilatório. Resultados: Trinta participantes foram tratados utilizando oxigenoterapia com cânula nasal de alto fluxo. Esta foi uma população mista com exacerbação de doença pulmonar obstrutiva crônica, edema pulmonar cardiogênico agudo, e insuficiência respiratória aguda pós-operatória e pós-extubação. Observou-se melhora não significante na frequência respiratória (28,0 ± 0,9 versus 24,3 ± 1,5; p = 0,22), que foi aparente nas primeiras 4 horas do tratamento. Ocorreu melhora do pH, embora só se tenham obtido níveis normais após 24 horas de tratamento com cânula nasal de alto fluxo (7,28 ± 0,02 versus 7,37 ± 0,01; p = 0,02). A proporção de não responsivos foi de 13,3% (quatro participantes), dos quais um necessitou e aceitou ventilação mecânica não invasiva, e três necessitaram de intubação. A mortalidade na unidade de terapia intensiva foi de 3,3% (um participante), e um paciente morreu após a alta para a enfermaria (mortalidade hospitalar de 6,6%). Conclusão: O oxigenoterapia com cânula nasal de alto fluxo é eficaz para a insuficiência respiratória hipercápnica moderada e ajuda a normalizar os parâmetros clínicos e de troca gasosa, com taxa aceitável de não responsivos que necessitaram de suporte ventilatório.

ABSTRACT Objective: To assess the efficacy and safety of high-flow nasal cannula oxygen therapy in treating moderate hypercapnic respiratory failure in patients who cannot tolerate or have contraindications to noninvasive mechanical ventilation. Methods: A prospective observational 13-month study involving subjects admitted to an intensive care unit with or developing moderate hypercapnic respiratory failure. Clinical and gas exchange parameters were recorded at regular intervals during the first 24 hours. The endpoints were a oxygen saturation between 88 and 92% along with a reduction in breathing effort (respiratory rate) and pH normalization (≥ 7.35). Subjects were considered nonresponders if they required ventilatory support. Results: Thirty subjects were treated with high-flow nasal cannula oxygen therapy. They consisted of a mixed population with chronic obstructive pulmonary disease exacerbation, acute cardiogenic pulmonary edema, and postoperative and postextubation respiratory failure. A nonsignificant improvement was observed in respiratory rate (28.0 ± 0.9 versus 24.3 ± 1.5, p = 0.22), which was apparent in the first four hours of treatment. The pH improved, although normal levels were only reached after 24 hours on high-flow nasal cannula therapy (7.28 ± 0.02 versus 7.37 ± 0.01, p = 0.02). The rate of nonresponders was 13.3% (4 subjects), of whom one needed and accepted noninvasive mechanical ventilation and three required intubation. Intensive care unit mortality was 3.3% (1 subject), and a patient died after discharge to the ward (hospital mortality of 6.6%). Conclusion: High-flow nasal cannula oxygen therapy is effective for moderate hypercapnic respiratory failure as it helps normalize clinical and gas exchange levels with an acceptable rate of nonresponders who require ventilatory support.
Descritores: Oxigenoterapia/métodos
Insuficiência Respiratória/terapia
Hipercapnia/terapia
Unidades de Terapia Intensiva
-Oxigênio/administração & dosagem
Oxigênio/metabolismo
Oxigenoterapia/efeitos adversos
Troca Gasosa Pulmonar
Estudos Prospectivos
Resultado do Tratamento
Cânula
Pessoa de Meia-Idade
Limites: Humanos
Masculino
Feminino
Idoso
Tipo de Publ: Estudo Observacional
Responsável: BR1.1 - BIREME


  6 / 26 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-1041676
Autor: Dell'Era, Silvina; Roux, Nicolás; Gimeno-Santos, Elena; Terrasa, Sergio.
Título: The High Flow Nasal Cannula Improves the Exercise Capacity in Patients with Chronic Obstructive Pulmonary Disease: Randomized, Crossover Clinical Trial
Fonte: Rev. am. med. respir;19(1):16-26, mar. 2019. ilus, graf, tab.
Idioma: en.
Resumo: Introduction: The effects of high flow nasal cannula (HFNC) such as reducing of work of breathing could improve exercise tolerance in stable chronic obstructive pulmonary disease (COPD) patients, however there is a great lack of evidence supporting its use. Aims: To compare the maximum speed (MS) reached on an Incremental Exercise Test (IET) and Limit Time (Tlim) on a Constant Work Rate Exercise Test (CWRET) using High Flow Nasal Cannula (HFNC) vs Venturi Mask (VM). Methods Subjects: 28 COPD patients (56% male, age mean 69 yr and FEV1 44% predicted) who require oxygen during exercise. Design: randomized crossover trial. Variables: MS, Tlim, symptoms, oxygen saturation (SpO2), heart rate, respiratory rate, blood pressure and comfort. Procedure: Each patient performed two IET and two CWRET, one time using HFNC and the other with VM. Statistic analysis: we carried out a hypothesis contrast of paired data comparing MS, Tlim and physiological variables. p < 0.05 was considered statistically significant. Results: HFNC vs MV increased MS (5,9 vs 5,7 km/h; p = 0.0002) and Tlim (450 vs 315 sec; p = 0.004), with higher SpO2 and less dyspnea (p < 0.05) at both isowork and isotime, with no statistically significant differences on confort. Conclusions: HFNC improved exercise capacity in COPD patients increasing MS during IET and Tlim on CWRET with higher SpO2 and reduced dyspnea in comparison to VM. HFNC and VM were equally comfortable.
Descritores: Oxigenoterapia
Reabilitação
Doença Pulmonar Obstrutiva Crônica
Cânula
Responsável: AR423.1 - Biblioteca


  7 / 26 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-1041675
Autor: Dell'Era, Silvina; Roux, Nicolás; Gimeno-Santos, Elena; Terrasa, Sergio.
Título: La cánula de alto flujo mejora la capacidad de ejercicio en pacientes con enfermedad pulmonar obstructiva crónica: ensayo clínico aleatorizado cruzado / High flow cannula improves exercise capacity in patients with chronic obstructive pulmonary disease: randomized crossover clinical trial
Fonte: Rev. am. med. respir;19(1):4-15, mar. 2019. ilus, graf, tab.
Idioma: es.
Resumo: Introducción: Los efectos de la cánula de alto flujo como reducción del trabajo respiratorio podrían mejorar la tolerancia al ejercicio en pacientes con enfermedad pulmonar obstructiva crónica (EPOC), aunque en la actualidad falta evidencia para recomendar su uso. Objetivos: Comparar la velocidad aeróbica máxima en un Test Incremental y el tiempo límite en un Test a Carga Constante utilizando cánula de alto flujo versus máscara de Venturi. Materiales y métodos: Ensayo clínico aleatorizado cruzado con 28 pacientes con EPOC (56% varones, edad promedio 69 años, VEF1 promedio 44% del predicho) y requerimiento de oxígeno durante el ejercicio. Variables analizadas: velocidad aeróbica máxima, tiempo límite, síntomas, saturación de oxígeno, frecuencia cardiaca y respiratoria, tensión arterial y confort. Cada paciente realizó dos Tests Incrementales y dos Tests a Carga Constante, uno con cánula de alto flujo y otro con máscara de Venturi. Para el análisis estadístico se empleó el contraste de hipótesis de datos apareados, comparando velocidad aeróbica máxima, tiempo límite y variables fisiológicas, considerando estadísticamente significativa una p < 0.05. Resultados: En comparación con la máscara de Venturi, la cánula de alto flujo aumentó la velocidad aeróbica máxima (5.9 vs. 5.7 km/h; p = 0.0002) y el tiempo límite (450 vs. 315 segundos; p = 0.004), con mayor SpO2 y menor disnea (p < 0.05) a isocarga e isotiempo, sin diferencias estadísticamente significativas en el confort. Conclusiones: La cánula de alto flujo mejoró la capacidad de ejercicio en pacientes con EPOC, aumentando la velocidad aeróbica máxima alcanzada en los Tests Incrementales y el tiempo límite en los Tests a Carga Constante con mayor SpO2 y disminución de la disnea en comparación con la máscara de Venturi. La cánula de alto flujo y la máscara de Venturi resultaron igual de confortables.
Descritores: Oxigenoterapia
Reabilitação
Doença Pulmonar Obstrutiva Crônica
Cânula
Responsável: AR423.1 - Biblioteca


  8 / 26 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-1041674
Autor: Salvado, Alejandro.
Título: Cánula de alto flujo en rehabilitación respiratoria / High flow cannula in respiratory rehabilitation
Fonte: Rev. am. med. respir;19(1):1-3, mar. 2019.
Idioma: es.
Resumo: En condiciones normales, cada respiración genera flujos de 15 litros/minuto (l/min), este aire es calentado y se humidifica en la vía aérea superior. Los gases alcanzan una temperatura de 36 °C y una humidificación del 80-90%. La inhalación de aire a través de la boca, sin embargo, reduce una humedad relativa cercana al 70%. Durante el ejercicio o en condiciones de dificultad respiratoria, como en los pacientes con EPOC, se pueden alcanzar caudales de hasta 120 l/min, lo que resulta en un aumento de la pérdida de fluidos y un mayor requerimiento metabólico de oxígeno para lograr calentar esos gases. Estas tasas de flujo son alcanzadas por cortos períodos de tiempo limitados por la fatiga. La aplicación de gases fríos y secos a pacientes con un mayor requerimiento de oxígeno puede exacerbar la pérdida de calor y se asocia en general con incomodidad y un cumplimiento reducido de la terapia. Cuando esto ocurre, la humidificación del gas disminuye por debajo del 50% de la humedad relativa, lo que puede provocar sequedad de las secreciones, obstrucción de las vías respiratorias y la desaturación arterial de oxígeno
Descritores: Reabilitação
Doença Pulmonar Obstrutiva Crônica
Cânula
Responsável: AR423.1 - Biblioteca


  9 / 26 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Carvalho, Werther Brunow de
Texto completo
Id: biblio-977069
Autor: Colleti Junior, José; Longui, Tâmara Eleamen; Carvalho, Werther Brunow de.
Título: Cânula nasal de alto fluxo pós-extubação traqueal em criança com obstrução de vias aéreas superiores: relato de caso / High-flow nasal cannula post-tracheal extubation in a child with upper airway obstruction: case report
Fonte: Rev. Paul. Pediatr. (Ed. Port., Online);36(3):372-375, jul.-set. 2018. graf.
Idioma: pt.
Resumo: RESUMO Objetivo: Relatar o caso de um lactente que necessitou de intubação traqueal no setor de emergência pediátrica por conta de laringite aguda grave e que, após a extubação traqueal programada, fez uso, com sucesso, da cânula nasal de alto fluxo, a qual, possivelmente, evitou a falha da extubação traqueal. Descrição do caso: Paciente masculino, 8 meses de idade, admitido no pronto atendimento de pediatria com desconforto respiratório agudo por causa de obstrução alta de vias aéreas secundária à laringite aguda grave. Foi imediatamente intubado e encaminhado para a unidade de terapia intensiva (UTI) pediátrica. Apresentou falha de extubação em função de edema importante de laringe evidenciado por broncoscopia, o que contraindicou a extubação. Na segunda tentativa de extubação, o paciente apresentou desconforto respiratório, melhorando após uso da cânula nasal de alto fluxo, com redução da frequência cardíaca e respiratória, possibilitando a extubação com sucesso. Comentários: O uso da cânula nasal de alto fluxo foi eficaz e apresentou boa resposta nesse paciente com laringite aguda, sugerindo ser um possível adjuvante para o tratamento, evitando-se a piora do quadro respiratório e da necessidade de reintubação.

ABSTRACT Objective: To report a case of a patient who required tracheal intubation in a pediatric emergency department due to acute laryngitis and that, after the planned extubation, has successfully used the high-flow nasal cannula, which possibly prevented extubation failure. Case description: A male 8-month-old child was admitted to the pediatric emergency room with acute respiratory distress due to a high airway obstruction secondary to severe acute laryngitis. He was immediately intubated and referred to the pediatric intensive care unit. He presented extubation failure due to a significant laryngeal edema evidenced by bronchoscopy. In the second attempt to extubate, he presented respiratory distress, but, after the use of the high-flow nasal cannula, he became stable, reducing the heart and respiratory frequencies, and the extubation was successful. Comments: The use of the high-flow nasal cannula was effective and presented good response in this patient with acute laryngitis, suggesting that it is a possible adjuvant for the treatment, avoiding worsening respiratory conditions and the need for reintubation.
Descritores: Laringite/terapia
Obstrução das Vias Respiratórias/terapia
Extubação
Intubação Intratraqueal
-Índice de Gravidade de Doença
Doença Aguda
Cânula
Limites: Humanos
Masculino
Lactente
Tipo de Publ: Relatos de Casos
Responsável: BR1.1 - BIREME


  10 / 26 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Texto completo
Id: biblio-1039038
Autor: Feitoza-Silva, Michele; Carvalho, Carolina Mesquita de; Bittencourt, Lívia Bretas; Leandro, Katia Christina; Gemal, André Luis.
Título: The importance of corrosion resistance test of cannulas in the quality control of hypodermic needles
Fonte: Braz. J. Pharm. Sci. (Online);55:e18148, 2019. tab, graf, ilus.
Idioma: en.
Resumo: According to Anvisa risk rating, hypodermic needles offer medium risk to the user's health. This study discussed the importance of the corrosion resistance test in tubes of hypodermic needles, in the product quality control. A review of cannulas of hypodermic needles was carried out according to ISO 9626:2003 and 9259:1997 ABNT NBR. For the results evaluation, a scale which classifies the extent of corrosion was adjusted. 174 samples of PNI needles from 17 States and 9 different record holders were analyzed. According to the methodology of ISO 9626:2003, 100% of the samples were considered satisfactory. However, in accordance with the methodology of ISO 9259:1997, 97.1% of the samples were rejected. Irregularities can lead to impairment of product quality, resulting in risks to the consumer's health. Since 2011 the product has undergone certification, so it is necessary to reflect on the importance of corrosion resistance testing and mandatory certification for health monitoring.
Descritores: Controle de Qualidade
Corrosão
Agulhas/normas
-Vigilância de Produtos Comercializados
Brasil/etnologia
Cromo/análise
Cânula
Legislação como Assunto/normas
Tipo de Publ: Estudo Comparativo
Responsável: BR40.1 - DBD - Divisão de Biblioteca e Documentacão do Conjunto das Químicas



página 1 de 3 ir para página          
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde