Base de dados : LILACS
Pesquisa : G01.590 [Categoria DeCS]
Referências encontradas : 9 [refinar]
Mostrando: 1 .. 9   no formato [Detalhado]

página 1 de 1

  1 / 9 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Mesquita, Marcelo Ferraz
Texto completo
Id: biblio-963829
Autor: Presotto, Anna Gabriella Camacho; Bhering, Cláudia Lopes Brilhante; Caldas, Ricardo Armini; Consani, Rafael Leonardo Xediek; Barão, Valentim Adelino Ricardo; Mesquita, Marcelo Ferraz.
Título: Photoelastic and finite element stress analysis reliability for implant-supported system stress investigation
Fonte: Braz. j. oral sci;17:e181097, 2018. ilus.
Idioma: en.
Resumo: Aim: To compare the reliability between photoelastic and finite element (FE) analyses by evaluating the effect of different marginal misfit levels on the stresses generated on two different implant-supported systems using conventional and short implants. Methods: Two photoelastic models were obtained: model C with two conventional implants (4.1×11 mm); and model S with a conventional and a short implant (5×6 mm). Three-unit CoCr frameworks were fabricated simulating a superior first pre-molar (P) to first molar (M) fixed dental prosthesis. Different levels of misfit (µm) were selected based on the misfit average of 10 frameworks obtained by the single-screw test protocol: low (<20), medium (>20 and <40) and high (>40). Stress levels and distribution were measured by photoelastic analysis. A similar situation of the in vitro assay was designed and simulated by the in silico analysis. Maximum and minimum principal strain were recorded numerically and color-coded for the models. Von Mises Stress was obtained for the metallic components. Results: Photoelasticity and FE analyses showed similar tendency where the increase of misfit generates higher stress levels despite of the implant design. The short implant showed lower von Mises stress values; however, it presented stresses around its full length for the in vitro and in silico analysis. Also, model S showed higher µstrain values for all simulated misfit levels. The type of implant did not affect the stresses around pillar P. Conclusions: Photoelasticity and FEA are reliable methodologies presenting similarity for the investigation of the biomechanical behavior of implant-supported rehabilitations
Descritores: Fenômenos Biomecânicos
Implantes Dentários
Análise de Elementos Finitos
Fenômenos Ópticos
Responsável: BR218.1 - Biblioteca Carlos Henrique Robertson Liberalli


  2 / 9 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: biblio-837396
Autor: Gomes, Ana Cristina Rocha; Nascimento, Reinaldo.
Título: Ilusão / Ilusion
Fonte: Prosthes. Lab. Sci;6(21):10-13, 2016. ilus.
Idioma: pt.
Resumo: A Odontologia Restauradora e a Protése devem satisfazer as exigências estéticas do paciente e contribuir para a saúde gengival e articular (oclusão). Para tanto, muitas vezes nos deparamos com desproporções dentoalveolares, maus posicionamentos, desvios de longo-eixo, inclinações axiais desfavoráveis, presenças de diastemas, etc. Para criar a percepção ilusória de dimensões e rotações diferentes das reais, podem ser utilizados artifícios ópticos dentro dos limites de tolerância visual. Esses artifícios vão desde o trabalho com a estratificação das cores utilizadas na restauração/prótese ao planejamento adequado da área plana (ou reflexiva), ângulos incisais, área de transição, linhas de brilho, textura, pontos de con-tatos proximais, etc. Este artigo aborda alguns princípios que podemos utilizar para alterar a percepção ilusória de um dente, aproveitando-se de fenômenos ópticos na superfície do esmalte.

Restorative dentistry and dental prosthesis must meet patients' aesthetic expectations and preserve gingival and articular health. In such circumstances it is common to observe dentoalveolar disproportion, poorly positioned teeth, large, deviations of the long axis, unfa-vorable axial inclination, diastema, etc. In order to create the illusion of different dimension and rotations, optical resources can be applied respecting visual tolerance limits. These resources range from the stratification of the colors used on the restoration/prostheses to proper planning of reflexive area, incisal angles, transition areas, texture, brightness, texture and proximal contact points. The present study approaches some principles that may be used in order to improve dental appearance through optical resources over enamel surface
Descritores: Estética Dentária
Luz
Fenômenos Ópticos
Limites: Humanos
Responsável: BR510.1 - Biblioteca Central


  3 / 9 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-678159
Autor: Cunha, Celso Marcelo; Correia, Renato José Bett; Sardinha Neto, Antonio Augusto.
Título: Lentes progressivas: análise dos campos intermediário e de perto por deflexometria / Progressive addition lenses: analysis of intermediate and near vision zones by deflectometry
Fonte: Arq. bras. oftalmol;76(1):33-37, jan.-fev. 2013. ilus, graf, tab.
Idioma: pt.
Resumo: OBJETIVO: Avaliar por deflexometria as diferentes regiões das lentes progressivas e determinar as áreas dos campos de visão intermediário e de perto. MÉTODOS: Foram incluídas vinte e duas lentes progressivas com poder +1,00 DE para longe e duas adições diferentes (adição 1,00 e 2,00, 11 de cada). Mediram-se as áreas dos campos intermediário e de perto entre as isoastigmáticas de 0,5 DC. RESULTADOS: Encontraram-se diferenças significativas entre as áreas dos campos intermediário e de perto das lentes estudadas. Entre a área do campo intermediário e a adição observou-se correlação inversa; entre a área do campo intermediário e a extensão vertical do corredor encontrou-se correlação direta. CONCLUSÃO: Com esses dados permitem-se recomendar as lentes de acordo com o campo de maior necessidade visual de cada usuário.

PURPOSE: To determine near and intermediate vision areas of progressive addition lenses by means of a deflectometer. METHODS: Twenty-two progressive addition lenses with +1.00 SD far power and two different additions (add 1.00 and 2.00; eleven subjects in each addition) were studied. Near and intermediate vision areas within 0.50 CD isoastigmatic lines were determined. RESULTS: There are significant differences between near and intermediate vision areas of the studied lenses. There is also an inverse correlation between the addition and intermediate areas as well as direct relation between the vertical length of the corridor and its area. CONCLUSION: Based on those findings, progressive addition lenses can be selected to suit the wearer's visual requirements.
Descritores: Óculos/normas
Fenômenos Ópticos
-Desenho de Equipamento
Interferometria/métodos
Responsável: BR1.1 - BIREME


  4 / 9 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Consani, Simonides
Sinhoreti, Mário Alexandre Coelho
Texto completo
Id: lil-572301
Autor: Guiraldo, Ricardo Danil; Consani, Simonides; Consani, Rafael Leonardo Xediek; Berger, Sandrine Bittencourt; Mendes, Wilson Batista; Sinhoreti, Mário Alexandre Coelho; Correr-Sobrinho, Lourenço.
Título: Comparison of silorane and methacrylate-based composite resins on the curing light transmission
Fonte: Braz. dent. j;21(6):538-542, 2010. ilus, tab.
Idioma: en.
Resumo: The aim of this study was to investigate the influence of different composite resins - Filtek P90 (silorane-based composite) and Heliomolar (methacrylate-based composite) - on light transmission and decrease in Knoop hardness between the bottom and top of cured specimens. The irradiance of a light-curing unit (LCU) was measured with a power meter (Ophir Optronics; 900 mw/cm2) and spectral distributions were obtained using a spectrometer (USB 2000). Twenty standardized cylindrical specimens (2 mm thick x 7 mm diameter) of each composite resin were obtained by curing using the LCU for 40 s. Light energy transmission through the composite was calculated (n=10). The Knoop hardness number for each surface was recorded as the mean of 3 indentations. The difference in Knoop hardness between the top and bottom (DKH) of the same specimen was calculated (n=10). The irradiance of light that passed through Filtek P90 (272 mW/cm2) was not significantly greater than that the passed through Heliomolar (271 mW/cm2). The DKH of Filtek P90 (25 percent) was significantly higher than that of Heliomolar (12 percent). There was a greater degree of subsurface polymerization of the methacrylate-based composite compared to the silorane-based composite.

O objetivo deste estudo foi avaliar a influência da diferença entre a dureza do topo e da base em compósitos restauradores. Foram utilizados os compósitos restauradores Filtek P90 (compósito à base de silorano) e Heliomolar (compósito à base de metacrilato). A irradiância da unidade foto-ativadodora (UF) foi mensurada com um potenciômetro Ophir Optronics (900 mw/cm2) e o espectro de luz foi obtido usando um espectrofotômetro (USB 2000). Vinte espécimes cilíndricos padronizados (2 mm de espessura por 7 mm de diâmetro) foram obtidos pela fotoativação utilizando UF (40 s) para cada compósito. A irradiância que passou através do compósito foi mensurada (n=10). O número de dureza Knoop para cada superfície foi calculado pela média de 3 penetrações. A diferença da dureza Knoop entre o topo e base (DDK) de um mesmo espécime foi calculada (n=10). A irradiância que passou através da Filtek P90 (272 mW/cm2) não foi estatisticamente superior a Heliomolar (271 mW/cm2). A DDK da Filtek P90 (25 por cento) foi estatisticamente superior a Heliomolar (12 por cento). O compósito a base de metacrilato apresentou melhor grau de polimerização na base quando comparado ao compósito à base de silorano.
Descritores: Resinas Compostas/química
Cura Luminosa de Adesivos Dentários
-Resinas Acrílicas
Análise do Estresse Dentário
Dureza
Teste de Materiais
Metacrilatos
Fenômenos Ópticos
Polimerização
Poliuretanos
Siloxanas
Tipo de Publ: Estudo Comparativo
Responsável: BR1.1 - BIREME


  5 / 9 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-557110
Autor: Dündar, Nesrin; Güneri, Pelin; Önem, Erinç; Boyacioğlu, Hayal.
Título: Construction of a copper stepwedge with aluminum equivalent mean gray values
Fonte: J. appl. oral sci;18(4):390-396, July-Aug. 2010. ilus, graf, tab.
Idioma: en.
Resumo: OBJECTIVES: To produce a copper (Cu) stepwedge with aluminum (Al) equivalent mean gray values (MGV). MATERIAL AND METHODS: The thicknesses of Cu steps that were equivalent to those of the Al were formulated using the X-ray attenuation properties of the materials. The Al and fabricated Cu stepwedges were radiographed, but the MGVs of the Cu stepwedge were mismatching to those of the Al. Using a mathematical function to adjust the pixel MGV of Cu stepwedge to those of the Al, new Cu stepwedges were created. In vitro iterations were performed until best approximation to Al was reached. RESULTS: The MGV of the Cu stepwedges fabricated by formularization were different than those of Al (p=0.001). Iteration method led to MGV similar to those of the Al stepwedge (p=0.207). CONCLUSIONS: Construction of a Cu stepwedge according to the basic rules of radiophysic failed to result in a stepwedge with similar radiodensity values to those of Al stepwedge. Further studies may use the formularization method only for prototype Cu wedge production, but consecutive iterations shall be compassed to obtain the best approximation to Al MGV.
Descritores: Absorciometria de Fóton/instrumentação
Alumínio/química
Cobre/química
Radiografia Panorâmica/instrumentação
-Algoritmos
Processamento de Imagem Assistida por Computador/métodos
Fenômenos Ópticos
Doses de Radiação
Padrões de Referência
Radiografia Panorâmica/normas
Espectrofotometria Atômica
Propriedades de Superfície
Filme para Raios X/normas
Limites: Humanos
Responsável: BR1.1 - BIREME


  6 / 9 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-540499
Autor: Bagnato, Vanderlei Salvador; Kurachi, Cristina; Castro-e-Silva, Orlando de.
Título: New perspectives for optical techniques in diagnostic and treatment of hepatic diseases / Novas perspectivas para técnicas ópticas no diagnóstico e tratamento de doenças hepáticas
Fonte: Acta cir. bras;25(2):214-216, Mar.-Apr. 2010.
Idioma: en.
Descritores: Fígado Gorduroso/diagnóstico
Análise Espectral/métodos
-Fenômenos Ópticos
Índice de Gravidade de Doença
Limites: Animais
Humanos
Responsável: BR1.1 - BIREME


  7 / 9 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Andreollo, Nelson Adami
Texto completo
Id: lil-533205
Autor: Nieri, Tâmara Maria; Peres, Marco Antonio de Oliveira; Silva, Emerson Rodrigo da; Fabbro, Inácio Maria Dal; Muramatsu, Mikiya; Andreollo, Nelson Adami.
Título: The optical analysis of the abdominal wall using the biospeckle after implants of polypropylene mesh in rats / Análise ótica da parede abdominal pelo biospeckle após implante de prótese de polipropileno em ratos
Fonte: Acta cir. bras;24(6):442-448, Nov.-Dec. 2009. ilus, tab.
Idioma: en.
Resumo: PURPOSE: To evaluate an experimental animal model to study the abdominal tissue activity considering its interaction with a polypropylene mesh, through the use of one of the optical phenomena of light Laser, the biospeckle. METHODS: Fifty Wistar male rats were divided into four groups: Group 1: ten animals not submitted to surgery; Group 2: ten animals submitted to surgery without polypropylene mesh; Group 3: 20 animals submitted to surgery followed by the mesh placement; Group 4: (sham) with ten animals. None of the animals presented post surgical complications being submitted to the optical tests at the 20th postoperative day. RESULTS: The analysis from the biospeckle tests, comparing the medians and standard deviations with T Student test, indicated that no significative difference was observed on the abdominal wall tissue activity in the four groups considered, with and without polypropylene mesh prosthesis implantation. CONCLUSION: The animal model is viable and the biospeckle open ways for a great number of experiments to be developed in evaluating tissue activity.

OBJETIVO: Avaliar o modelo experimental animal para o estudo da atividade tecidual da parede abdominal em sua interação com a prótese de polipropileno, através da utilização de um dos fenômenos ópticos da luz Laser, o biospeckle. MÉTODOS: Foram utilizados 50 ratos Wistar machos, divididos em quatro grupos: Grupo 1 com 10 animais não operados e controles; Grupo 2 com 10 animais submetidos a cirurgia sem a colocação de prótese; Grupo 3 com 20 animais submetidos a cirurgia com colocação de prótese de polipropileno pré-peritonial; Grupo 4 (Sham) com 10 animais. Nenhum animal apresentou complicações pós-operatórias, sendo que no 20º PO foram submetidos ao ensaio óptico. RESULTADOS: A comparação das médias e o desvio padrão das medidas da atividade tecidual da parede abdominal, com e sem implantação da prótese de polipropileno obtidas dos grupos de animais, pelo teste T de Student, não evidenciou diferença estatística significativa (p>0.05). CONCLUSÃO: A análise dos dados obtidos permitiu concluir que o modelo animal é viável e que o biospeckle abre caminhos para toda uma linha de experimentos a ser desenvolvida em avaliar atividade tecidual.
Descritores: Parede Abdominal/cirurgia
Aumento da Imagem/normas
Lasers
Fenômenos Ópticos
Polipropilenos
Telas Cirúrgicas/efeitos adversos
Cicatrização/fisiologia
-Parede Abdominal/patologia
Aumento da Imagem/métodos
Modelos Animais
Polipropilenos/efeitos adversos
Polipropilenos/uso terapêutico
Complicações Pós-Operatórias/patologia
Distribuição Aleatória
Ratos Wistar
Aderências Teciduais/patologia
Limites: Animais
Masculino
Ratos
Responsável: BR1.1 - BIREME


  8 / 9 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-479761
Autor: Moraes, Luciene Gonçalves Palmeira; Rocha, Renata Sanches Ferreira; Menegazzo, Lívia Maluf; Araújo, Eudes Borges de; Yukimito, Keizo; Moraes, João Carlos Silos.
Título: Infrared spectroscopy: a tool for determination of the degree of conversion in dental composites
Fonte: J. appl. oral sci;16(2):145-149, Mar.-Apr. 2008. graf, tab.
Idioma: en.
Resumo: Infrared spectroscopy is one of the most widely used techniques for measurement of conversion degree in dental composites. However, to obtain good quality spectra and quantitative analysis from spectral data, appropriate expertise and knowledge of the technique are mandatory. This paper presents important details to use infrared spectroscopy for determination of the conversion degree.
Descritores: Resinas Compostas/química
Materiais Dentários/química
Espectroscopia de Infravermelho com Transformada de Fourier
-Absorção
Algoritmos
Calibragem
Fenômenos Químicos
Carbono/química
Metacrilatos/química
Metilmetacrilato/química
Fenômenos Ópticos
Polímeros/química
Polimetil Metacrilato/química
Espectroscopia de Infravermelho com Transformada de Fourier/métodos
Espectroscopia de Infravermelho com Transformada de Fourier/normas
Limites: Humanos
Responsável: BR1.1 - BIREME


  9 / 9 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-479759
Autor: Braun, Ana Paula; Grassi Soares, Clarissa; Glüer Carracho, Helena; Pereira da Costa, Nilza; Bauer Veeck, Elaine.
Título: Optical density and chemical composition of microfilled and microhybrid composite resins
Fonte: J. appl. oral sci;16(2):132-136, Mar.-Apr. 2008. ilus, tab.
Idioma: en.
Resumo: This study evaluated the optical density of two microfilled and two microhybrid resins, as well as the composition of these materials with regard to their optical density. Cavities prepared in 12 2-mm- or 4-mm-thick acrylic plastic plates were filled with Z250 (3M-ESPE), A110 (3M-ESPE), Charisma (Heraeus-Kulzer) and DurafillVS (Heraeus-Kulzer). The resin increments (2-mm-thick) were light-cured for 40 s. Three 0.12-s radiographic exposures were made of each #2 acrylic plastic plate. DenOptix system optical plates were used to obtain the digital images. Three readings of the composite resin surface were made in each radiograph, totalizing 216 readings. The mean of highest and lowest grey-scale values was obtained. Two specimens of each composite resin were prepared for SEM analysis of the chemical elements related to optical density, using energy dispersive x-ray analysis (EDX). The results were subjected to Shapiro-Wilk's test, ANOVA, Tukey's test at 1 percent level of significance and Pearson's correlation. The mean grey-scale values at 2 mm and 4 mm were: Z250 = 154.27a and 185.33w; A110 = 46.77b and 63.05y; Charisma = 163.40c and 200.46z; DurafillVS = 43.92b and 58.99x, respectively. Pearson's test did not show any positive correlation between optical density and percentage weight of optical density chemical elements. It was concluded that the microhybrid resins had higher optical density means than the microfilled resins; among the evaluated resins, Charisma had the highest optical density means.
Descritores: Resinas Compostas/química
Materiais Dentários/química
-Alumínio/análise
Bário/análise
Fenômenos Químicos
Resinas Compostas/análise
Densitometria
Materiais Dentários/análise
Microanálise por Sonda Eletrônica
Processamento de Imagem Assistida por Computador
Teste de Materiais
Microscopia Eletrônica de Varredura
Fenômenos Ópticos
Radiografia Dentária
Propriedades de Superfície
Fatores de Tempo
Zinco/análise
Limites: Humanos
Tipo de Publ: Research Support, Non-U.S. Gov't
Responsável: BR1.1 - BIREME



página 1 de 1
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde