Base de dados : LILACS
Pesquisa : HP7.029.141.162.126.096 [Categoria DeCS]
Referências encontradas : 8 [refinar]
Mostrando: 1 .. 8   no formato [Detalhado]

página 1 de 1

  1 / 8 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-633051
Autor: Luna, José Rafael; Di Bernardo, María Luisa; García, María Ysabel; Ovalles, Fernando; Calderón, Laura.
Título: Determinación de paraquat en orina utilizando un sistema de inyección en flujo continuo / Determination of paraquat in urine samples by flow-injection analysis
Fonte: Acta bioquím. clín. latinoam;42(2):251-259, abr.-jun. 2008. ilus, graf, tab.
Idioma: es.
Resumo: El paraguat es un herbicida que pertenece al grupo de los biperidilos. Su determinación cuantitativa en orina es muy importante para diagnosticar la supervivencia de pacientes intoxicados. Muchos centros hospitalarios utilizan pruebas semicuantitativas para la determinación de paraquat en muestras biológicas. Sin embargo, éstas suelen carecer de precisión y exactitud. Por tanto, el desarrollo de métodos alternativos simples, exactos, precisos y accesibles podría resultar muy útil en instituciones hospitalarias. Sobre la base de estas consideraciones, se propone un método de análisis por inyección en flujo y detección espectrofotométrica para la determinación cuantitativa de paraquat en muestras de orina. La determinación se basa en la formación de un producto coloreado (600 nm) posterior a la reducción de paraquat con glucosa en un medio alcalino, mediante un sistema en línea. Bajo las condiciones óptimas de operación, la ley de Beer se cumple en el intervalo 1-50 µg mL-1 de paraquat con un coeficiente de correlación >0,999. La frecuencia de análisis fue de 12 h-1 con una desviación estándar relativa del 2,8% para una solución muestra que contiene 10 µg mL-1 de paraquat (n=3). El estudio de recuperación osciló entre 97,9 y 102,1%. El método analítico fue aplicado satisfactoriamente al análisis de muestras de dos pacientes intoxicados con paraquat.

Paraguat is a herbicide beloging to the bipyridinium group.The quantitative determination of paraquat in urine of humans is very important to diagnose survival of intoxicated patients. Many hospitals use semi-quantitative tests for determining paraquat in biological samples. However, they often lack precision and accuracy. Therefore, the development of simple, precise, accurate and accessible alternative methods could be very useful in hospital institutions. Based on these considerations, a flow-injection spectrophotometric procedure is proposed for paraquat determination in urine samples. The determination is based on the formation of a coloured product (600 nm) after on-line reduction of paraquat with glucose in alkaline medium. Under optimal conditions of operation, Beer's law is obeyed in a concentration range of 1-50 µg mL-1 of paraquat with a correlation coefficient >0.999. The analytical frequency was 12 h-1 and the relative standard deviation was 2.8% for a sample solution containing 10 µg mL-1 paraquat (n=3). Recovery studies were between 97.9 and 102.1%. The analytical method was satisfactorily applied in the analyses of samples from two intoxicated patients.
Descritores: Paraquat/urina
-Paraquat/envenenamento
Paraquat/toxicidade
Espectrofotometria/métodos
Fluxo Contínuo
Técnicas de Química Analítica/métodos
Herbicidas
Tipo de Publ: Estudo de Validação
Responsável: AR1.2 - Instituto de Investigaciónes Epidemiológicas


  2 / 8 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: biblio-915736
Autor: ABFH.
Título: Congresso brasileiro de farmácia homeopática, VII / Mesa redonda: fluxo contínuo - aspectos legais e clínicos para preparação acima de 100M FC / Brazilian congress of homeopatic pharmacy, VII.
Fonte: São Paulo; TV Med; 2009. ? p.
Idioma: pt.
Descritores: Fluxo Contínuo
Farmácia Homeopática
Responsável: BR926.1 - Biblioteca Artur de Almeida Rezende Filho
BR926.1, 2009, PT 1


  3 / 8 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-455462
Autor: Teixeira, Edmilson Costa; Chacaltana, Julio Tomás Aquije; Siqueira, Renato do Nascimento; Pacheco, Camila Gomes.
Título: Proposta de calibração de modelos hidrodinâmicos aplicados a unidades de contato utilizando uma função de distribuição de tempos de residência / A proposal of calibration of hydrodynamic models of contact units using a residence time distribution function
Fonte: Eng. sanit. ambient;12(1):79-89, jan.-mar. 2007. ilus, tab, graf.
Idioma: pt.
Resumo: O desempenho de unidades de contato que operam em regime de fluxo contínuo depende, entre outros, do padrão de escoamento que se desenvolve no seu interior. Já o levantamento de dados experimentais, como a elevação da superfície d'água e do campo de velocidades, não é uma tarefa fácil. Por tais razões, o uso de modelos numéricos na obtenção de padrões de escoamento em unidades de contato tem se tornado uma boa alternativa. A falta de dados hidrodinâmicos para a calibração e verificação de modelos numéricos tem sido um dos principais fatores que vem limitando o uso mais extensivo dessa ferramenta. O presente trabalho propõe uma nova técnica de calibração de modelo numérico, baseada no ajuste de curvas de passagem obtidas pelo modelo numérico e as obtidas experimentalmente ao longo das unidades de contato. A metodologia proposta é parcialmente avaliada e os resultados indicam ser essa uma técnica bastante promissora.

The performance of continuous flow contact units relies, among other factors, on the flow pattern inside them, and that the measurement of flow patterns in this type of unit is not an easy task. For this reason, the use of numerical models to obtain flow patterns in contact units has become a good alternative. However, the lack of hydrodynamic data to calibrate the models has been one of the main factors limiting a more extensive use of numerical models for this purpose. This work proposes a new calibration technique for numerical models which is based on the best fitting of measured and simulated flow through curves throughout the unit. The proposed methodology is partially evaluated and the results indicate it to be very promising.
Descritores: Calibragem
Fluxo Contínuo
Modelos Teóricos
Modelos Teóricos
Escoamento Superficial
Responsável: BR559.1 - Centro de Informação e Documentação em Saúde


  4 / 8 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-236361
Autor: Dutra, R. A. F; Morais, M. M. C; Silva, V. L. da; Lima Filho, J. L.
Título: Biosensor de ácido úrico para determinaçäo em fluxo contínuo / Uric acid biosensor for continuous flow determination
Fonte: In: Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.291-2.
Idioma: pt.
Conferência: Apresentado em: Fórum Nacional de Ciência e Tecnologia em Saúde, 3 e Congresso Brasileiro de Engenharia Biomédica, 15 e Congresso Brasileiro de Físicos em Medicina, 6 e Congresso Brasileiro de Informática em Saúde, 5 e Encontro Brasileiro de Proteçäo Radiológica, Campos do Jordäo, 13-17 out. 1996.
Resumo: O objetivo deste trabalho foi desenvolver um biosensor para dosagens de ácido úrico no soro humano. A uricase foi imobilizada em pasta de grafite modificada usando TCNQ como mediador e então, pressionada sobre um eletrodo de outo. A corrente elétrica produzida pela reação enzimática foi diretamente proporcional à concentração de ácido úrico presente na amostra. Este sistema demonstrou uma sensibilidade linear entre 12.5 muM a 250 muM de solução de ácido úrico. O sistema foi testado usando medições em fluxo contínuo (FIA).
Descritores: Ácido Úrico/administração & dosagem
Fluxo Contínuo
Urato Oxidase
-Ácido Úrico/sangue
Consumo de Oxigênio
Limites: Humanos
Responsável: BR1.1 - BIREME
BR1.1; 3011.146


  5 / 8 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-114367
Autor: Cesar, Amarilys de Toledo.
Título: Medicamentos homeopaticos: e possivel a padronizacao? / Homeopathic medicament: standardization is it possible?
Fonte: Rev. homeopatia (Säo Paulo);(175):5-8, out.-dez. 1987.
Idioma: pt.
Descritores: Escala Centesimal
Farmacotécnica Homeopática/métodos
-Fluxo Contínuo
Padrões de Referência
Responsável: BR926.1 - Biblioteca Artur de Almeida Rezende Filho


  6 / 8 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-114294
Autor: Castro, Alfredo.
Título: A qualidade do medicamento homeopatico, sob o ponto de vista farmaceutico, terapeutico e clinico: comentarios e criticas / The homeopathic medicament quality, under the pharmaceutical, therapeutical and clinical point of view: commentaries and criticism
Fonte: Rev. homeopatia (Säo Paulo);(164):3-10, jan.-mar. 1985. ilus.
Idioma: pt.
Conferência: Apresentado em: Congresso da Liga Medica Homeopatica Internacional, 39, Buenos Aires, 8 nov. 1984.
Descritores: Medicamento Homeopático/normas
Potência
Qualidade dos Medicamentos Homeopáticos
-Fluxo Contínuo
Dinamização
Transferência de Energia
Farmacotécnica Homeopática/métodos
Altas Potências/uso terapêutico
Altas Potências/estatística & dados numéricos
Controle de Qualidade
Responsável: BR926.1 - Biblioteca Artur de Almeida Rezende Filho


  7 / 8 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-114232
Autor: Boiron, J.
Título: Algumas precisoes sobre as "diluicoes" homeopaticas / Some explantions about the homeopathic \"dilutions\"
Fonte: Rev. homeopatia (Säo Paulo);(150):22-30, jul.-set. 1981. ilus.
Idioma: pt.
Descritores: Método Hahnemanniano/história
Método de Korsakov/história
-Dinamização/história
Fluxo Contínuo/história
Farmacotécnica Homeopática
Responsável: BR926.1 - Biblioteca Artur de Almeida Rezende Filho


  8 / 8 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Id: lil-114190
Autor: Winston, Julian.
Título: Uma breve historia das maquinas de dinamizar / A brief history of potentizing machines
Fonte: Rev. homeopatia (Säo Paulo);55(4):100-6, dez. 1990. ilus.
Idioma: pt.
Resumo: De 1850 a 1920, coincidindo com o avanco da ciencia e tecnologia da Revolucao Industrial, alguns homeopatas tentaram construir maquinasque economizariam trabalho, pelas quais eles poderiam gerar potencias elevadas. Este artigo descreve estas invencoes, das quais temos ouvido muito, mas no geralpouco sabemos
Descritores: Dinamização Mecânica/história
Fluxo Contínuo/história
-Dinamização Mecânica/métodos
Dinamização/história
Dinamização/métodos
Altas Potências
Altas Potências/história
HISTORIA DA HOMEOPATIA DO SECULO ABO BLOOD-GROUP SYSTEM
HISTORIA DA HOMEOPATIA DO SECULO ABOMASUM
Limites: História do Século XIX
História do Século XX
Tipo de Publ: Artigo Histórico
Responsável: BR926.1 - Biblioteca Artur de Almeida Rezende Filho



página 1 de 1
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde