Id: lil-596479
Autor: Neves, Zilah Cândida Pereira das; Melo, Dulcelene de Sousa; Souza, Adenícia Custódia Silva e; Tipple, Anaclara Ferreira Veiga; Rodrigues, Márcia Alves Vasconcelos.
Título: Artigos esterilizados em calor úmido: validação do sistema de guarda / Items sterilized in humid heat: validation of the storage system / Esterilización de artículos en calor humedo: validez del sistema protector
Fonte: Rev. bras. enferm;57(2):152-156, mar.-abr. 2004. graf, tab.
Idioma: pt.
Resumo: Objetivamos identificar o tempo de validade da esterilização dos artigos processados pelo calor úmido, considerando as condições de esterilização e guarda. A validação deu-se através de testes microbiológicos realizados com instrumentais processados numa mesma carga e avaliados em tempos 0, 7, 10, 15 e 25 dias. Foram analisados 30 por cento do instrumental de cada pacote que foi colocado em caldo Mueller Hinton e incubado a 37ºC por 72 horas. A leitura deu-se pela turvação do caldo. Das amostras avaliadas de nove cargas, em nenhuma houve crescimento microbiológico. Concluiu-se que apesar das condições de esterilização e guarda do material não se adequarem totalmente dentro dos parâmetros recomendados pela literatura, a esterilização ocorreu e manteve-se por um período de 25 dias.

We aimed at identifying the period of validity of the sterilization of items by humid heat, taking into account the conditions of sterilization and storage. The validation was carried out by means of microbiological tests performed with instruments in the same load and evaluated in 0, 7, 10, 15, and 25 days. 30 percent of the instruments in each package were analysed and put in a Mueller Hinton solution and incubated at 37ºC for 72 hours. The reading was accomplished taking into consideration how dark the solution was. Out of the samples evaluated in nine loads, none showed microbiological growth. It was concluded that, although sterilization and storage conditions of the material were not fully in accordance with parameters recommended by the literature, the sterilization happened and was maintained for a period of 25 days.

El estudio tiene por objeto identificar el tiempo de validez de la esterilización de los artículos procesados por el vapor saturado bajo presión, considerando las condiciones de esterilización y almacenaje. La validez se dio a través de pruebas microbiológicas que se realizaron con instrumentales procesados en una misma carga y evaluados en tiempos 0, 7, 10, 15 y 25 días. Se analizó el 30 por ciento del instrumental de cada paquete que fue colocado en caldo Mueller Hinton e incubado en 37ºC por 72 horas. La lectura se realizó por la turbidez del caldo. En las muestras analizadas de nueve cargas, en ninguna de ellas hubo crecimiento microbiológico. Se concluyó que, aunque las condiciones de esterilización y almacenaje del material no se adecuan totalmente dentro de los parámetros recomendados, la esterilización ocurrió y se mantuvo por un período de 25 días.
Descritores: Temperatura Alta
Umidade
Embalagem de Produtos/normas
Esterilização/normas
Tipo de Publ: Estudo Multicêntrico
Responsável: BR1.1 - BIREME


  2 / 54 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-654865
Autor: Cassola, Maria Águida.
Título: Validação do processo de selagem em embalagens de produtos reprocessados na central de esterilização / Validation of sealing process for medical devices reprocessed in central supplies sterilization departments
Fonte: Rev. SOBECC;17(2):33-38, abr.-jun. 2012. ilus.
Idioma: pt.
Resumo: Em função da complexidade e da necessidade de se estabelecerm rotinas e procedimentos operacionais padrão, que são interligados desde a limpeza até o armazenamento de materisis e produtos em centrais de esterilização, a validação de processos de selagem parece ser algo pouco divulgado e até certo ponto um ato que passa despercebido. Neste cenário, o presente artigo tem como objetivo servir de guia para enfermeiros de centrais de esterilização quanto ao conhecimento do processo de validação de embalagens e a obtenção de um guia simplificado para execução dos processos de validação de selagem de materiais esterelizados...
Descritores: Embalagem de Produtos
Equipamentos e Provisões Hospitalares/microbiologia
Esterilização/instrumentação
Estudos de Validação como Assunto
Responsável: BR442.1 - Biblioteca Setorial de Pós-Graduação


  3 / 54 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-431198
Autor: Pinter, Márcia Galluci; Gabrielloni, Maria Cristina.
Título: Validação de embalagens de algodão duplo e papel grau cirúrgico: relato de experiência / Drug packaging
Fonte: Acta paul. enferm;13(n.esp,pt.2):94-95, 2000.
Idioma: pt.
Descritores: Embalagem de Produtos
Tampões de Gaze Cirúrgicos/normas
Limites: Humanos
Responsável: BR21.1 - Biblioteca J Baeta Vianna- Campus Saúde UFMG


  4 / 54 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-974888
Autor: Araujo, Graciela Machado de; Reisdorfer, Nara; Silva, Luiz Anildo Anacleto da; Soder, Rafael Marcelo; Santos, Adriane Marines dos.
Título: Segurança do paciente: embalagens, acondicionamento e tempo de guarda de materiais esterilizados na atenção básica / Seguridad del paciente: envases, acondicionamiento y tiempo de guarda de materiales / Safety: packages, packing and storage period of sterilized materials in primary care
Fonte: Ciênc. cuid. saúde;15(4):662-668, Out.-Dez. 2016.
Idioma: pt.
Resumo: RESUMO As unidades básicas de saúde possuem grande demanda de procedimentos médicos, de enfermagem e odontológicos, dos quais dependem a segurança da assistência e do paciente. O objetivo deste estudo foi compreender como enfermeiros, técnicos, auxiliares em enfermagem e auxiliares de consultório dentário procedem no cuidado com embalagens, acondicionamento e tempo de guarda de materiais esterilizados nas unidades de saúde da atenção básica. Trata-se de uma pesquisa de caráter descritivo e exploratório, com abordagem qualitativa. Os participantes da pesquisa foram enfermeiros, técnicos de enfermagem e auxiliares de consultório dentário, atuantes em unidades básicas de saúde de três cidades do interior do Estado do Rio Grande do Sul. Os dados foram produzidos por meio de entrevistas semiestruturadas realizadas nos meses de outubro e dezembro de 2015 e submetidos a análise de conteúdo. Evidenciou-se que os serviços estudados carecem de estruturação, organização e definição de processos no que tange o tipo de embalagem e o acondicionamento de artigos críticos. Conclui-se que a assistência aos usuários, no que se refere a procedimentos que utilizam materiais esterilizados, está exposta a riscos, fragilizando a segurança do paciente, evidenciando a necessidade de capacitação continua dos profissionais.

RESUMEN Las unidades básicas de salud poseen gran demanda de procedimientos médicos, de enfermería y odontológicos, de los cuales depende la seguridad de la atención y del paciente. El objetivo de este estudio fue comprender cómo enfermeros, técnicos, auxiliares en enfermería y auxiliares de consultorio dentario proceden en el cuidado con envases, acondicionamiento y tiempo de guarda de materiales esterilizados en las unidades de salud de la atención básica. Se trata de una investigación de carácter descriptivo y exploratorio, con abordaje cualitativo. Los participantes de la investigación fueron enfermeros, técnicos de enfermería y auxiliares de consultorio dentario, actuantes en unidades básicas de salud de tres ciudades del interior del Estado de Rio Grande do Sul-Brasil. Los datos fueron producidos por medio de entrevistas semiestructuradas realizadas en los meses de octubre y diciembre de 2015 y sometidos al análisis de contenido. Se evidenció que los servicios estudiados carecen de estructuración, organización y definición de procesos con relación al tipo de envase y el acondicionamiento de artículos críticos. Se concluye que la atención a los usuarios, en lo que se refiere a procedimientos que utilizan materiales esterilizados, está expuesta a riesgos, fragilizando la seguridad del paciente, evidenciando la necesidad de capacitación continua de los profesionales.

ABSTRACT The basic health units have great demand for medical, nursing and dentistry procedures, on which the security of the assistance and the patient depends. The objective of this study was to understand how nurses, nursing technicians, assistants and dental office assistants proceed in managing packaging, guard and distribution of sterile materials in the health units of the primary care. This is a descriptive and exploratory research, with a qualitative approach. The participants of the research were nurses, nursing technicians and assistants of dental office operating in basic health units of three cities in the State of Rio Grande do Sul. The data were generated through semi-structured interviews between October and December 2015 and assessed through content analysis. One evidenced that the studied services lack structure, organization and process definition with regard to the packaging of critical objects. The conclusion is that the assistance to users with respect to procedures using sterile materials are exposed to risks, weakening the patient's safety, emphasizing the need for continuous training of professionals.
Descritores: Atenção Primária à Saúde/organização & administração
Esterilização/instrumentação
Embalagem de Produtos/instrumentação
Embalagem de Medicamentos/instrumentação
Segurança do Paciente
-Auxiliares de Odontologia
Consultórios Odontológicos/organização & administração
Equipamentos e Provisões
Técnicos de Enfermagem
Enfermeiras e Enfermeiros
Assistentes de Enfermagem
Limites: Humanos
Masculino
Feminino
Tipo de Publ: Relatos de Casos
Responsável: BR513.1 - Biblioteca Central


  5 / 54 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-713501
Autor: Mussel, Ivone Coutinho.
Título: Armazenamento dos produtos para saúde estéreis no centro de esterilização e unidades assistenciais de hospitais grande porte de Belo Horizonte / Storage of the Sterile Products for Health in Sterilization Center and Assistance Units in large-scale hospitals in Belo Horizonte.
Fonte: Belo Horizonte; s.n; 2013. 78 p. tab.
Idioma: pt.
Tese: Apresentada a Universidade Federal de Minas Gerais. Escola de Enfermagem para obtenção do grau de Mestre.
Resumo: O produto para saúde (PPS) esterilizado, quando armazenado nas unidades assistenciais de saúde, deve ser mantido em condições adequadas ou semelhantes ao Centro de Material e Esterilização (CME), visando tanto à garantia para o tempo de validade como o uso seguro para o paciente. Muitos aspectos e desafios na manutenção da esterilidade a exemplo, características da área física hospitalar, tipo de embalagem utilizada e acesso restrito podem influenciar a qualidade do armazenamento do PPS estéril. Este estudo orientou-se pela pergunta: Quais são as condições de acondicionamento do PPS estéril nas unidades de assistência direta e no CME? Para responder à questão, propôs-se como objetivo: Analisar as condições dos locais de guarda dos produtos estéreis para saúde em unidades assistenciais e no CME de hospitais grande porte de Belo Horizonte. Trata-se de estudo exploratório, descritivo, de abordagem quantitativa. Foram selecionadas 11 instituições. Os dados foram obtidos por meio de um instrumento contendo aspectos relacionados à estrutura física, à infraestrutura, à organização do ambiente e às condições de armazenamento. A coleta de dados foi realizada no período de maio a setembro de 2013, a análise dos dados foi processada com base no programa estatístico Statistical Package for the Social Science, versão 19.0, por meio de análise descritiva, com a apresentação de valores absolutos e porcentagens. A caracterização do CME, com base nas informações obtidas dos respondentes (100% enfermeiros) evidenciou-se a presença de janelas lacradas (60%). A distância mínima exigida do teto foi encontrada em (100%) das instituições, sendo em (90%) distancia das paredes e (80%) distancia do chão. Quanto ao acondicionamento do material estéril, foram encontrados armários fechados (60%), com revestimento lavável (100%). O controle de umidade relativa do ar e temperatura foi referido como realizado em todos os CME, variando os parâmetros adotados. A data de vali...

The sterile health product (SHP) when stored in the health care units should be kept in appropriate or similar to the Material and Sterilization Center (MSC) conditions, in order to guarantee both the shelf life and safe of use. Many aspects and challenges in maintaining the sterility for instance, hospital physical characteristics, used packaging type and restricted access may influence the quality of storage of sterile PPS. This study was guided by the following question: What are the conditions for packaging of sterile PPS units in direct assistance and in the MSC? To answer the question, it was proposed as objective: To analyze the conditions of the custody places for sterile products for health care units and large scale hospitals and MSC of Belo Horizonte. This is an exploratory and descriptive study with a quantitative approach. 11 institutions were included. Data were collected by means of an instrument containing aspects related to the physical structure, infrastructure, and organization of the environment as well as storage conditions. Data collection was conducted in the period May to September 2013, data analysis was performed based on the Statistical Package for the Social Sciences, version 19.0 , using descriptive analysis, with the presentation of absolute values and percentages. The characterization of the MSC, based on information obtained from the respondents (100 % nurses) showed the presence of sealed windows (60 %). The minimum required distance was found in the ceiling (100 %) of the institutions, and in (90 %) and distance of the walls (80 %) distance from the ground. As for the packaging of sterile equipment, closed cabinets (60 %) were found, with washable lining (100 %). The control of temperature and relative humidity was referred to as held in all MSC, varying the parameters adopted. The expiration date of the SHP was reported as sterile checked in (100 %) of the MSC. Transport in exclusive cars occurs in 80 % ...
Descritores: Administração de Materiais no Hospital
Armazenamento de Produtos
Embalagem de Produtos
-Infecção Hospitalar/prevenção & controle
Inquéritos e Questionários
Limites: Humanos
Responsável: BR21.1 - Biblioteca J Baeta Vianna- Campus Saúde UFMG
BR21.1; T-WX147, MUAR


  6 / 54 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-553935
Autor: Serratine, Ana Claudina Prudêncio; Gonçalves, Claudia de Souza; Luçolli, Isabelle Cassatti.
Título: Influência do armazenamento e da embalagem na manutenção da esterilidade do instrumental odontológico / Influence on storage and packing to maintain the sterility of dental equipment
Fonte: Rev. eletrônica enferm;11(1):158-164, 2009. ilus.
Idioma: pt.
Resumo: Este estudo teve por objetivo verificar o prazo de validade da esterilização de instrumental embalado e armazenado sob diversas condições. Foram confeccionados 395 corpos de prova metálicos, que após contaminação com Enterococcus faecalis (ATCC 19433, NEWPROV) foram subdivididos em seis grupos, compostos por 65 unidades. Cada grupo foi embalado, respectivamente, com papel Kraft, crepado, grau cirúrgico com filme, papel alumínio, tecido de algodão cru duplo e tecido tipo brim. Depois de submetidos à esterilização, os pacotes foram subdivididos, permanecendo trinta de cada tipo acondicionados em caixa plástica fechada e os demais soltos no interior do mesmo armário fechado. Após períodos de 7, 15, 30, 45, 90 e 148 dias, corpos de prova contidos em cinco pacotes de cada tipo de material de embalagem e armazenamento foram inoculados em meio de cultivo e incubados à 37oC por quarenta e oito horas. Após este tempo a análise microbiológica era realizada para verificar a manutenção da esterilidade dos espécimes. Todos os corpos de prova permaneceram estéreis por até 148 dias nas condições de empacotamento e armazenamento testadas. Contudo, sugere-se que as instituições de saúde realizem investigações para validar o tempo de manutenção da esterilidade dos artigos, de acordo com sua própria rotina.
Descritores: Armazenamento de Substâncias, Produtos e Materiais
Embalagem de Produtos
Esterilização/instrumentação
Esterilização/métodos
Instrumentos Odontológicos
Reprodutibilidade dos Testes
-Controle de Infecções Dentárias/instrumentação
Responsável: BR584.1 - Biblioteca Central BSCAN


  7 / 54 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-768563
Autor: Tomé, Mariana Fexina; Lima, Antônio Fernandes Costa.
Título: Mapeamento do processo de reprocessamento de campos cirúrgicos de tecido de algodão / Mapping the process of reprocessing cotton drapes
Fonte: Rev. SOBECC;20(4), out.-dez. 2015. ilus.
Idioma: pt.
Resumo: Mapear o processo de reprocessamento de campos de tecido de algodão, duplos e simples, integrantes dos pacotes de LAP cirúrgico. Método: Estudo de caso exploratório, descritivo, conduzido no Serviço de Rouparia (SR) e no Centro de Material e Esterilização (CME) de um hospital de ensino. Acompanhou-se a condução de todo o processo por meio de observações não participantes no SR e no CME e, posteriormente, realizou-se reuniões com profissionais representantes do SR (camareiras) e do CME (auxiliares e técnicos de enfermagem), visando o detalhamento, complementação e validação das etapas e atividades observadas. Resultados: Foram mapeadas quatro etapas: processamento das roupas por lavanderia terceirizada, recepção das roupas no SR, montagem e esterilização dos pacotes de LAP e armazenamento dos pacotes de LAP no CME. Conclusão: O mapeamento possibilitou a visualização dos recursos consumidos nas etapas e atividades constituintes do processo, fornecendo informações que contribuirão para a alocação racional dos recursos envolvidos...
Descritores: Campos Cirúrgicos
Custos e Análise de Custo
Embalagem de Produtos
Esterilização
Roupa de Proteção
Limites: Humanos
Responsável: BR442.1 - Biblioteca Setorial de Pós-Graduação


  8 / 54 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: lil-438775
Autor: Alarcon, Caroline dal Pian; Graziano, Kazuko Uchikawa; Hadi, Mohamad Abdul; Camargo, Tamara Carolina de.
Título: Contêiners rígidos: avaliação dos usuários / Hard containers: users evaluation
Fonte: Rev. SOBECC;10(2):33-39, abr.-jun. 2005. graf.
Idioma: pt.
Resumo: Os contêineres rígidos constituem uma tecnologia de embalagem importada que difere das tradicionais por dispor de sistemas de filtros para saída de ar e entrada do vapor, dispensando o uso do invólucro externo. Considerando que toda novidade deve ser investigada, este estudo se propôs a analisar os contêineres rígidos de acordo com a avaliação dos usuários quanto às suas vantagens e desvantagens...
Descritores: Embalagem de Produtos
Esterilização
Infecção Hospitalar/prevenção & controle
Tipo de Publ: Estudo Comparativo
Responsável: BR442.1 - Biblioteca Setorial de Pós-Graduação


  9 / 54 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Andrade, Denise de
Texto completo
Id: lil-591423
Autor: Ferreira, Adriano Menis; Andrade, Denise de.
Título: Microbial contamination of procedure gloves after opening the container and during exposure in the environment / Contaminação microbiana das luvas de procedimento após a abertura da caixa e durante sua exposição ambiental / Contaminación microbiana de guantes de procedimiento luego de la abertura de la caja y durante exposición ambiental
Fonte: Rev. Esc. Enferm. USP;45(3):745-750, jun. 2011. tab.
Idioma: en.
Resumo: The objective of this study was to quantify the colony forming units (cfu) on latex procedure gloves in the beginning, middle, and end of the containers in real (professional) and controlled (researcher) gloving situations; evaluate the microbial load of the gloves, considering the time of exposure in the environment. This comparative prospective study was conducted at an intensive care unit of a teaching hospital. The microbiological data was collected from the gloves using digital-pressure. Microbiological evaluations were performed on 186 pairs of gloves: 93 in the control group and 93 in real gloving situations. In the control group, the average cfu was 4.7 against 6.2 in the real gloving situation. Hence, no statistically significant difference was found (p=.601). In addition, the cfu values of gloves in the beginning, middle and end of the containers also did not show any significant differences (p>.05). The most common strain was Staphylococcus spp. The time of exposure in the environment did not increase the cfu value of the latex gloves.

Este trabalho teve como objetivo quantificar as Unidades Formadoras de Colônias (ufc) das luvas de látex para procedimentos no início, meio e fim das caixas na situação real (profissional) e controle (pesquisador) de enluvamento; avaliar a carga microbiana das luvas considerando o tempo de exposição ambiental. Trata-se de um estudo comparativo e prospectivo realizado em uma unidade de terapia intensiva de um hospital-escola. A coleta das amostras microbiológicas das luvas foi realizada por meio da digito-pressão. Avaliaram-se microbiologicamente 186 pares de luvas, 93 no grupo controle e 93 na situação real de enluvamento. No grupo controle a média de ufc foi de 4,7 e na situação real de enluvamento 6,2, consequentemente, não houve diferença estatisticamente significante (p=.601). Também, as ufc no inicio, meio e fim das caixas não se observou diferenças significante (p>.05). A cepa Staphylococcus spp. foi a mais freqüente. O tempo de exposição ambiental das luvas de látex não determinou aumento de ufc.

Trabajo que objetivó cuantificar las Unidades Formadoras de Colonias (UFC) en guantes de látex para procedimientos al inicio, mitad y final de las cajas en situación real (profesional) y control (investigador) de uso de guantes: evaluar carga microbiana de guantes considerando tiempo de exposición ambiental. Estudio comparativo prospectivo realizado en unidad de terapia intensiva de hospital-escuela. La recolección de muestras microbiológicas de guantes se realizó mediante dígito presión. Se evaluaron microbiológicamente 186 pares de guantes, 93 en grupo control y 93 en situación real de uso. En grupo control, la media de UFC fue de 4,7 y en situación real 6,2. Consecuentemente, no hubo diferencia estadísticamente significativa (p>0,601). Tampoco se observó diferencia significativa de UFC en comienzo, mitad y final de cajas (p>0,05). La cepa Staphylococcus spp. fue la más frecuente. El tiempo de exposición ambiental de los guantes de látex no determinó aumento de UFC.
Descritores: Contaminação de Equipamentos
Luvas Cirúrgicas/microbiologia
-Meio Ambiente
Embalagem de Produtos
Estudos Prospectivos
Tipo de Publ: Estudo Comparativo
Responsável: BR1.1 - BIREME


  10 / 54 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo
Texto completo
Id: biblio-1049088
Autor: Rubim, Raquel Fialho; Freitas, Silvério de Paiva; Vieira, Henrique Duarte; Oliveira, Anna Christina Sanazário de; Lemos, Gloria Cristina da Silva.
Título: Effect of packaging materials and storage environment on fennel seedling growth / Efeito da embalagem e do ambiente de armazenamento no crescimento de plântulas de erva doce
Fonte: Biosci. j. (Online);35(6):1664-1673, nov./dec. 2019. graf, tab.
Idioma: en.
Resumo: The objective of the present study was to assess the influence of the packaging material (cotton cloth bag, multifolium paper and glass container) and storage environment (laboratory and cold chamber conditions) on fennel seedling growth. Seeds were placed in different packaging materials and exposed to the two environments for twelve months. Assessments were made before storage and at every two months and the following were determined: total emergence, emergence speed index, seedling fresh and dry matter. A completely randomized experimental design was used, with four replications in a 2 x 3 x 6+1 factorial design in split split plots, where the plot was the storage environment (laboratory and cold chamber conditions); the split plot was the storage (cotton cloth bag, multifolium paper and glass container) and the split plot was the storage periods (2, 4, 6, 8, 10 and 12 months) and plus an additional treatment (before storage). The results showed that the fennel seedlings had superior growth when their seeds were placed in the glass packaging material, regardless of the storage environment.

O objetivo deste trabalho foi avaliar a influência da embalagem (saco de algodão, papel multifoliado e vidro) e do ambiente de armazenamento (condições de laboratório e câmara fria) no crescimento de plântulas de erva doce. Para isso, as sementes foram acondicionadas nas diferentes embalagens e expostas aos dois ambientes durante doze meses. As avaliações foram feitas antes do armazenamento e a cada dois meses, tendo sido determinado: emergência total, índice de velocidade de emergência, massa fresca e seca das plântulas. Utilizou-se o delineamento experimental inteiramente casualizado, com quatro repetições, num esquema fatorial 2 x 3 x 6 + 1 em parcelas subsubdivididas, no qual a parcela foi o ambiente de armazenamento (condições de laboratório e câmara fria); a subparcela as embalagens (saco de algodão, papel multifoliado e vidro) e a subsubparcela os períodos de armazenamento (2, 4, 6, 8, 10 e 12 meses) e mais um tratamento adicional (antes do armazenamento). Pelos resultados, demonstrou-se que as plântulas de erva doce apresentaram crescimento superior quando suas sementes foram acondicionadas na embalagem de vidro, independente do ambiente de armazenamento.
Descritores: Embalagem de Produtos
Pimpinella
Foeniculum
Armazenamento de Alimentos
-Sementes
Responsável: BR396.1 - Biblioteca Central



página 1 de 6 ir para página                
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde