Base de dados : LILACS
Pesquisa : SP4.016.147.648.099 [Categoria DeCS]
Referências encontradas : 7 [refinar]
Mostrando: 1 .. 7   no formato [Detalhado]

página 1 de 1

  1 / 7 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-913679
Autor: Avila, Rafael Doñate.
Título: O índice de diluição de esgoto e o estudo de caso da região metropolitana de São Paulo / The sewage dilution index and the case study of São Paulo's metropolitan area.
Fonte: São Paulo; s.n; 2018. 132 p.
Idioma: pt.
Tese: Apresentada a Universidade de São Paulo. Faculdade de Saúde Pública. Departamento de Saúde Ambiental para obtenção do grau de Mestre.
Resumo: A implantação e a ampliação dos sistemas de esgotamento sanitário devem contemplar não só aspectos políticos, técnicos e econômicos, mas também sociais, ambientais e de sustentabilidade. Para subsidiar a tomada de decisão com base neste paradigma, e auxiliar na definição das prioridades de intervenções, propõe-se aqui um novo indicador de sustentabilidade, que aqui foi denominado de Índice de Diluição de Esgoto - IDE. Este índice correlaciona a vazão de esgoto sanitário não tratado com a vazão dos corpos d'água e permite efetuar a avaliar o sistema de esgotamento sob a ótica da capacidade suporte do ambiente. A revisão bibliográfica abordou quatro temas: os esgotos sanitários, os recursos hídricos superficiais, a poluição dos corpos d'água por esgoto sanitário e os indicadores de sustentabilidade. Com base nos parâmetros de qualidade padrões dos esgotos sanitários e dos corpos d'água limpos, bem como na legislação ambiental, foram identificadas quatro faixas de risco associadas aos valores do IDE: acima de 0,1% há o risco à saúde e à eutrofização de represas, acima de 5% à comunidade aquática, acima de 10% à harmonia paisagística e acima de 15% à harmonia odorífera. Com o IDE desenvolvido, foi estudado o caso da Região Metropolitana de São Paulo - RMSP: o valor do índice foi calculado para as suas diversas sub-bacias de esgotamento. As bacias com os maiores valores de IDE situam-se em um anel que circunda a RMSP, enquanto que aquelas com os menores valores, nas porções interna e externa deste anel. Poucas sub-bacias apresentaram valores inferior a 0,1% e muitas apresentaram valores acima de 15%, que extrapola os 200% em alguns casos. O estudo da RMSP foi realizado à luz de variáveis territoriais e socioeconômicas, o que propiciou uma discussão do diagnóstico e do planejamento do sistema de esgotamento sob a ótica da sustentabilidade e dos riscos associados

The implementation and expansion of sewage systems should include not only political, technical and economic aspects, but also social, environmental and sustainability aspects. In order to support decision-making based on this paradigm and to endorse the interventions's priorities selection, a new sustainability indicator is proposed here, which has been called Sewage Dilution Index - SDI. This index correlates untreated sanitary sewage flow with the water bodies flow and allows the evaluation of the sewage system from the perspective of environmental support capacity. The literature review addressed four themes: sanitary sewage, surface water resources, pollution of water bodies by sanitary sewage and sustainability indicators. Based on the sanitary sewers and clean water bodies quality parameters standard, as well as environmental legislation, four risk ranges were identified associated with SDI values: above 0.1% a health and reservoir eutrophication risk was identified, above 5% an aquatic community risk, above 10% a landscape harmony risk and above 15% an odoriferous harmony risk. After the SDI was developed, it was accomplished the São Paulo's Metropolitan Area - SPRA case study: the sewage's índex values was calculated for it's sewage's sub-basins. The sub-basins with the highest values of SDI are located in a ring that surrounds the SPRA, whereas those with the lowest values are located inside and outside of this ring. Few sub-basins presented values below 0,1% and many showed values above 15%, which exceeds 200% in some cases. The SPRA case study was accomplished associated with territorial and socioeconomic variables, which allowed a discussion of the diagnosis and planning of the sewage system from the sustainability and associated risks point of view
Descritores: Planejamento Ambiental
Medição de Vazão
Esgotos
Indicadores de Desenvolvimento Sustentável
-Gestão Ambiental
Recursos Hídricos
Responsável: BR67.1 - CIR - Biblioteca - Centro de Informação e Referência


  2 / 7 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Andrade, Aron Jose Pazin de
Id: lil-556120
Autor: Colantonio, Robson; Lucchi, Julio César; Andrade, Aron José Pazin de.
Título: Avaliação de desempenho em um medidor eletromagnético de baixo custo desenvolvido para aplicações em simulação cardiovascular / Performance evaluation on low cost electromagnetic flow meter for cardiovascular simulation system application
Fonte: Rev. bras. eng. biomed = Braz. j. biomed. eng;25(2):101-105, ago. 2009. ilus, tab.
Idioma: pt.
Resumo: Técnicas cirúrgicas, próteses e dispositivos implantáveis utilizados pela cardiologia estão em constante desenvolvimento. Alguns institutos de pesquisas e universidades desenvolvem simuladores hidrodinâmicos com capacidade de reproduzir os níveis de pressão e vazão do sistema cardiovascular humano, com pistões, válvulas, câmaras de complacência, dispositivos para ajustes e medição de pressão e vazão. Este artigo apresenta o desenvolvimento e a avaliação de um fluxômetro eletromagnético (FE). O custo elevado de um fluxômetro por ultrassom (FUS) pode inviabilizar algumas pesquisas com simuladores; desta forma, uma alternativa com menor custo é apresentada neste trabalho. Baseado na indução eletromagnética para medição de vazão em um fluido iônico, o FE desenvolvido mostrou ser uma solução de baixo custo. O transdutor foi montado em um tubo de plástico com diâmetro interno de 9,5 mm, excitado por um campo magnético de 0,35 T, possui 4 eletrodos que, ligados a um circuito eletrônico, fornecem tensão elétrica proporcional à velocidade do fluido. A equação da tensão induzida, técnicas para calibração, ensaios e resultados são apresentados. Para a realização dos ensaios, foram utilizados um simulador cardiovascular e um FUS como referência. Os dados foram obtidos por hardware e software da National Instruments. Dentre os resultados, destaca-se o baixo desvio padrão de 0,043 L/min do FE para uma vazão de 3,56 L/min. O maior erro porcentual relativo foi de 1,49 ± 1,25%. Em um dos gráficos de vazão do FE observou-se um comportamento não monotônico, confirmado por uma análise da resposta em freqüência, observando-se maior amplitude na segunda, terceira e quarta harmônicas. Os resultados indicaram que o FE pode substituir o FUS em aplicações com simuladores hidrodinâmicos.

Implantable devices, prosthesis and their associated surgical techniques in cardiology are constantly under development. Many research groups have been using hydrodynamic simulators as a tool to assist the development in cardiovascular area, capable to mimic pressure and flow found in human cardiovascular system. They are made with plastic tubes, compliances chambers, valves, moving diaphragms and clamps for pressure and flow adjustments. The high cost of ultrasonic flow meters (UF) may difficult, for some research groups, the development of their own mock systems. This paper presents a simple and low cost electromagnetic flow meter (EF) useful for those cardiovascular simulation systems. EF measures flow of ionic fluids based on electromagnetic induction. A special transducer was assembled directly on a plastic tube with 9.5 mm of inner diameter. The transducer has 4 electrodes and, when excited by a magnetic field of 0.35 tesla, detects electric tension that is proportional to the fluid velocity. In this paper, induced electric potential equation, calibration techniques, performance tests and results are presented. A cardiovascular simulation system was used as test setup with an UF (Transonic Systems Inc.) as comparative flow meter. The signals were acquired by a PCI-6036E card and processed with LabView® 7.1 (National Instruments). The results from EF showed a standard deviation (SD) of 0.043 L/min for a flow of 3.56 L/min. The largest relative error was of 1.49 ± 1.25%. In one flow signal from the EF, the non monotonic behavior suggests a rich harmonic signal, which was confirmed by an analysis in the frequency domain. In vitro performance tests indicated that our EF can substitute the commercial available UF for hydrodynamic simulator application.
Descritores: Medição de Vazão
Fluxômetros
Modelos Cardiovasculares
Simulação por Computador
-Equipamentos de Medição
Técnicas de Diagnóstico Cardiovascular/instrumentação
Responsável: BR1178.1 - BVS ADOLEC BRASIL


  3 / 7 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Id: lil-147062
Autor: Miguel, Mario Edmundo.
Título: Informe final de macromedición y pitometría.
Fonte: Tijuana; OPS/CESPT; 1992. 215 p. tab.
Idioma: es.
Resumo: Señala los objetivos, metodología y conceptualización de los programas de macromedición y pitometría. Presenta diagnóstico de la situación y afirma que actualmente se realizan mediciones eventuales con el Pitot Simplex, pero bajo condiciones inadecuadas para obtención de la exactitud requerida. Explica que la macromedición la empresa no lleva en adelante mediciones de nivel y de presión y aunque tenga 36 macromedidores instalados no los utiliza de manera continua y la investigación de fugas no se hace de manera sistemática, sino que atiende a reclamos de los usuarios. Anexa: propuesta de actividades; política de operación de la unidad de planeación de operación; programa de actividades ; desarrollo del sistema de macromedición; investigación de fugas, manual de procedimientos, registros, análisis y organización de la información y macromedición
Descritores: Saúde Ambiental
Medição de Vazão
Pitometria
Medição de Consumo
-Programação
Responsável: PE8.1 - Biblioteca
PE8.1/SAC*4600*M56*7109


  4 / 7 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Id: lil-146530
Autor: Arbeláez Caicedo, Eduardo.
Título: Macromedición: proyecto de actividades.
Fonte: Lima; CEPIS; 1986. 24 p. ilus.
Idioma: es.
Resumo: Examina los objetivos del proyecto de macromedición. Estima el estado actual de la macromedición en las Empresas Municipales de Cali. Considera una evaluación en los medidores de caudal, de presión y de niveles de agua. Analiza la necesidad de medidores para el sistema y tipo de información requerida de los equipos. Determina la frecuencia y flujo de informaciones procedentes del sistema de macromedición enviadas al centro de control de la operación. Incluye criterios para la selección de medidores
Descritores: Saúde Ambiental
Medição de Vazão
Responsável: PE8.1 - Biblioteca
PE8.1/4612*A66*18970


  5 / 7 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Id: lil-146390
Autor: Sáenz Forero, Rodolfo.
Título: Importancia de la macromedición.
Fonte: Lima; CEPIS; 1982. 22 p. ilus, tab.
Idioma: es.
Resumo: Evalúa los diferentes aparatos que ha desarrollado la industria para llevar a cabo la llamada macromedición en los sistemas de abastecimiento de agua potable. Releva la importancia de la macromedición, destacando que permite determinar el rendimiento y conocer los costos unitarios de producción, distribución y comercialización del agua potable; señala que la macromedición tiene ingerencia en la planificación y diseño de las obras de agua potable y desagüe, así como en el control de fugas. Menciona algunos parámetros que pueden ser obtenidos a través de la macromedición. Comenta en forma especial el llamado medidor de derivación o proporcional
Descritores: Medição de Vazão
Consumo de Água (Saúde Ambiental)
Responsável: PE8.1 - Biblioteca
PE8.1/SAC*4612*S14*12100


  6 / 7 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Id: lil-146385
Autor: Pérez Carrión, José.
Título: Medición de flujos en estructuras hidráulicas de contorno abierto.
Fonte: Lima; CEPIS; 1982. 38 p. tab.
Idioma: es.
Resumo: Presenta la teoría y metodología de ejecución de ensayos y resultados de aforo en canales; utilizando molinetes, tubos Pitot, criterios de continuidad, vertederos, aforadores Parshall y Palmer y sustancias trazadoras para aforos por dilución. Incluye una serie de gráficos y tablas donde considera los esquemas y conceptos para la aplicación de cálculos en todos y cada uno de los métodos de medición anteriormente mencionados
Descritores: Escoamento em Dutos Fechados
Saúde Ambiental
Medição de Vazão
Hidrostática
Responsável: PE8.1 - Biblioteca
PE8.1/3103*P45*12102


  7 / 7 LILACS  
              first record previous record
seleciona
para imprimir
Id: lil-146294
Autor: Londoño Cubillos, Alvaro.
Título: Sistema comercial en las instituciones de agua potable y alcantarillado; subsistema de medición, catastro, facturación y cobranza.
Fonte: Lima; CEPIS; 1985. 354 p. ilus. (DTIAPA. Manual, C-12).
Idioma: es.
Resumo: Guía dirigida a los directivos y profesionales que laboran en el área comercial de las instituciones de agua potable y alcantarillado, con el objeto de contribuir a la difusión del sistema comercial, a la formación de recursos humanos para el área comercial y a la administración eficaz de dichas instituciones. Presenta el sistema comercial, sus funciones, estructura y un plan para su implantación. Contiene: subsistema de medición de consumos; caracterización del subsistema; medidores de agua; administración del sistema de medidores; subsistema de catastro, caracterización del subsistema, registro catastral de los usuarios, establecimiento del catastro, mantenimiento del catastro, corrientes de comunicación del subsistema, modelo de boletín de censo; subsistema de facturación y cobranza, caracterización del subsistema, procesos de facturación y cobranza, organización de cuentas, informaciones de entrada y salida de los procesos de facturación y cobranza, ciclo de emisión, procesamiento de datos, evaluación y sistema de catastro
Descritores: Saúde Ambiental
Medição de Vazão
Empresas de Saneamento Básico
Empresas de Água Potável
Responsável: PE8.1 - Biblioteca
PE8.1/4609*L82*17573