Base de dados : LILACS
Pesquisa : SP4.016.152.678.124 [Categoria DeCS]
Referências encontradas : 3 [refinar]
Mostrando: 1 .. 3   no formato [Detalhado]

página 1 de 1

  1 / 3 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: biblio-986472
Autor: Mamani A, Edwin J; Alcon M, Juan; Alejo T, Marcó; García F, Fabricio; Moscoso M, Gustavo; Pérez M, Carlos; Pinto J, Jhovana; Rendón N, Andrés; Revilla F, Efraín; Salazar G, Andrea; Velásquez B, Rommel.
Título: pH del agua potable que consumen estudiantes del segundo año de la Carrera de Medicina, Universidad Mayor de San Andrés Gestión 2017 / pH of drinking water that second year students of medicine of the Universidad Mayor de San Andres consume term 2017
Fonte: Cuad. Hosp. Clín = Cuad. - Hosp. clín;59(2):36-39, 2018. ilus..
Idioma: es.
Resumo: INTRODUCCIÓN: El pH es una propiedad básica del agua potable y cuyos valores extremos pueden originar reacciones secundarias dañinas, entendiéndose por agua potable aquel que puede ser consumido sin restricción para el consumo humano, OBJETIVO: Determinar el valor del pH de agua potable que consumen los estudiantes de segundo año de la carrera de medicina de la Universidad Mayor de San Andrés (UMSA). MATERIAL Y MÉTODOS: Se analizaron 388 muestras de agua potable del domicilio de estudiantes regulares de segundo año cátedra de bioquímica entre los meses de julio y agosto del 2017, realizándose un estudio de tipo descriptivo con un enfoque transeccional. RESULTADOS: Se obtuvieron los siguientes resultados, 1) la media del pH total fue de 7,24; con x=7,22 en la ciudad de la Paz y x=7,28 en la ciudad de el Alto. 2) en cuanto al sistema de potabilización se obtuvo: x=7,34 en la planta el Alto, x=7,21 en la planta de Tilata, x=7,15 en la planta de Achachicala y de x=7,20 en la planta de Pampahasi. CONCLUSIONES: El pH del agua potable consumida se encontró dentro de parámetros establecidos con un valor medio de 7,24.

INTRODUCTION: The pH is a basic property of potable water and whose extreme values may cause harmful secondary reactions. It is understood that potable water can be consumed without any restriction by human beings. OBJECTIVE: To determine the pH value of potable water consumed by medicine students of second year at UMSA university. MATERIAL AND METHODS: 388 samples of potable water were analyzed which were taken from the homes of the second year students of the biochemistry department between July and August 2017, developing a descriptive study with a cross-sectional approach. RESULTS: The following results were obtained: 1) the average of the pH was 7.24; with x = 7.22 in La Paz city and x = 7.29 in El Alto city. 2) in relation to the drinking water was obtained: x=7.34 in El Alto plant, x=7.21 in Tilata plant, x=7.16 in Achachicala plant and x=7.21 in Pampahasi plant. CONCLUSION: The pH of the drinking water drunk is established within parameters with an average value of 7.24.
Descritores: Água Potável
Alcalinidade da Água
Purificação da Água/estatística & dados numéricos
Plantas de Tratamento da Água/análise
-Água Potável/análise
Responsável: BO138.1 - Biblioteca Central


  2 / 3 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-622823
Autor: Deshmukh, Devendra V; Puranik, Pravin R.
Título: Statistical evaluation of nutritional components impacting phycocyanin production in Synechocystis SP
Fonte: Braz. j. microbiol;43(1):348-355, Jan.-Mar. 2012. ilus, tab.
Idioma: en.
Resumo: Alkaliphilic cyanobacterial cultures were isolated from Lonar lake (MS, India). Among the set of cultures, Synechocystis sp, was studied for phycocyanin production. A maximum yield was obtained in BG-11 medium at optimized conditions (pH 10 and 16 h light). In order to increase the phycocyanin yield media optimization based on the eight media components a Plackett-Burman design of the 12 experimental trials was used. As per the analysis CaCl2.2H2O and Na2CO3 have been found to be the most influencing media components at 95% significance. Further the optimum concentrations of these components were estimated following a Box Wilson Central Composite Design (CCD) with four star points and five replicates at the center points for each of two factors was adopted for optimization of these two media components. The results indicated that there was an interlinked influence of CaCl2.2H2O and Na2CO3 on 98% significance. The maximum yield of phycocyanin (12% of dry wt) could be obtained at 0.058 g/l and 0.115 g/l of CaCl2.2H2O and Na2CO3, respectively.
Descritores: Alcalinidade da Água/métodos
Cianobactérias/isolamento & purificação
Ficocianina
Phycomyces/isolamento & purificação
Carbonato de Sódio
Análise Estatística
Synechocystis/isolamento & purificação
-Fenômenos Fisiológicos Bacterianos
Fluorescência
Lagoas
Métodos
Técnicas
Amostras de Água
Tipo de Publ: Estudo Comparativo
Responsável: BR32.1 - Serviço de Biblioteca e Informação Biomédica


  3 / 3 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: lil-445707
Autor: Ferreira Filho, Eloy Alves; Chui, Queenie Siu Hang.
Título: Qualidade de medições e neutralização de efluentes alcalinos com dióxido de carbono / Quality of measurements and neutralization of alkaline effluents with carbon dioxide
Fonte: Eng. sanit. ambient;11(2):169-174, abr.-jun. 2006. ilus, tab.
Idioma: pt.
Resumo: O controle de pH de efluentes industriais, para fins de descarga, é estabelecido por leis estaduais e federais. Devido ao não conhecimento da incerteza de suas medições e principalmente não se conhecendo sua rastreabilidade a padrões nacionais e/ou internacionais, pode ocorrer não conformidade ao se permitir a descarga de efluente ao meio ambiente. Este trabalho enfoca a qualidade das medições de pH, através dos aspectos da rastreabilidade e da incerteza de medição, seguindo os conceitos introduzidos pela ISO GUM. O experimento foi realizado com amostra de efluente alcalino coletado de uma indústria têxtil, envolvendo a reação de neutralização usando o dióxido de carbono. Resultados de pH acompanhados de suas incertezas oferecem informação mais completa na prevenção contra descargas impróprias de efluentes ao meio.

State and federal laws rule the control of pH of industrial effluents aiming discharge and environmental protection. Improper effluent discharges can occur if obtained pH measurements do not meet traceability to national and/or international standards and are not associated with their uncertainties. This work focuses the quality of the pH measurements and follows the ISO GUM instructions by demonstrating the traceability and estimating the uncertainty of the measurements. The experiment was carried out using an alkaline effluent sample of a textile industry, involving the neutralization reaction with carbon dioxide. Having pH measurements associated with its uncertainty can prevent risks of improper discharge of effluent to the environment.
Descritores: Águas Residuais
Dióxido de Carbono
Poluição Ambiental
Efluentes Industriais
Indústria Têxtil
Alcalinidade da Água
Recursos Hídricos
-Concentração de Íons de Hidrogênio
Responsável: BR559.1 - Centro de Informação e Documentação em Saúde



página 1 de 1
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde