Base de dados : LILACS
Pesquisa : SP4.021.202.133.699.560 [Categoria DeCS]
Referências encontradas : 3 [refinar]
Mostrando: 1 .. 3   no formato [Detalhado]

página 1 de 1

  1 / 3 LILACS  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: lil-599363
Autor: Assalone, Melina; Santisteban, Raquel; Rabahia, Christian; Bertinatto, Jessica; Ithuralde, Leandro; Gruc, Olga; Larrinaga, Alicia; Spinetto, Marta; Chiale, Carlos.
Título: Desarrollo y validación de un método de valoración para oseltamivir en cápsulas y polvo para suspensión oral / Development and validation of a method for quantitative determination of oseltamivir in capsules and powder for oral suspension
Fonte: Rev. argent. salud publica;2(7):28-32, jun. 2011. tab, graf.
Idioma: es.
Resumo: INTRODUCCIÓN: la Organización Mundial de la Salud (OMS) declaró la pandemia de gripe A H1N1 en 2009. La autoridad sanitaria argentina promovió el desarrollo y validación de un método de control de calidad de productos farmacéuticos que contenían oseltamivir como principio activo. OBJETIVO: Desarrollar y validar un método de valoración para oseltamivir en las formas farmacéuticas de cápsulas y polvo para suspensión oral. MÉTODOS: La valoración de oseltamivir fue realizada mediantecromatografía líquida de alta eficacia (CL AE), con elusión isocrática a una temperatura de 50°C, columna Phenomenex Luna RP-8, solución reguladora de acetato pH 5,39 y metanol como fase móvil. La detección se realizó con detector de arreglo de diodos a 230 nm. El método fue validado mediante la evaluación de especificidad, retención en filtros, estabilidad de las soluciones, linealidad, exactitud, precisión y robustez. RESULTADOS: Se desarrolló y validó un método por CLAE para la valoración de oseltamivir, el cual fue aplicado con resultados satisfactorios en el análisis de 11 especialidades medicinales de laboratorios nacionales e internacionales. CONCLUSIONES: El método desarrollado puede aplicarse para el control de todos los productos del mercado argentino en sus dos formas farmacéuticas.

INTRODUCTION: Tthe World Health Organization(WHO) declared the pandemic influenza A H1N1 virus infection in 2009. Argentine health authorities promoted the development and validation of a quality control method for pharmaceutical products containing oseltamivir as active ingredient. OBJECTIVE: To develop and validate a method for oseltamivir quantitative determination in the pharmaceutical dosage forms of capsules and powder for oral suspension. METHODS: The determination of oseltamivir was performed using a high performance liquid chromatography (HPLC) method under an isocratic elution, at a temperature of 50°C with a RP-8 Phenomenex Luna column and a mobile phase containing acetate buffer pH 5.39 and methanol. The detection was performed at 230nm with a diodearray detector. The method was validated by evaluating specificity, filter retention, solution stability, linearity, accuracy, precision and robustness. RESULTS: An HPLC method was developed and validated for quantitative determination of oseltamivir, and it was successfully applied in the analysis of eleven medical products from national and international laboratories. CONCLUSIONS:The method developed can be applied for control of all products on the Argentine market in its two pharmaceutical forms.
Descritores: Cromatografia Líquida de Alta Pressão
Cápsulas/farmacologia
Controle de Medicamentos e Entorpecentes
Gestão da Qualidade
Oseltamivir
Controle de Qualidade
Soluções
Sólidos em Suspensão
Vírus da Influenza A Subtipo H1N1
Limites: Seres Humanos
Tipo de Publ: Estudos de Validação
Responsável: AR392.1 - Biblioteca


  2 / 3 LILACS  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Chile
Texto completo
Id: lil-551891
Autor: Donoso-Bravo, Andrés; Carballa, Marta; Ruiz- Filippi, Gonzalo; Chamy, Rolando.
Título: Treatment of low strength sewage with high suspended organic matter content in an anaerobic sequencing batch reactor and modeling application
Fonte: Electron. j. biotechnol;12(3):13-14, July 2009. ilus, tab.
Idioma: en.
Projeto: FONDECYT.
Resumo: In this work, an anaerobic sequencing batch reactor (ASBR) was operated for 8 months to treat low strength sewage with high suspended organic matter content. Three phases of operation with increasing organic loading rates (OLR) were performed: 0.4 kg COD/m³ x d (phase I), 0 .8 kg COD/m³ x d (phase II) and 1.2 kg COD/m³ x d (phase III). Adequate stability parameters (pH, total alkalinity) were obtained through all three experimental phases. During phases I and II, the removal efficiencies of organic matter (expressed as total chemical oxygen demand (COD) and total suspended solids ranged between 50-60 percent. However, these values decreased to 15-25 percent in phase III. In addition, a non-complex model, including hydrolysis, acidogenesis and methanogenesis, was applied to predict the reactor behavior.
Descritores: Digestão Anaeróbia
Bactérias Anaeróbias/isolamento & purificação
Tratamento de Águas Residuárias
-Lodos Ativados
Hidrólise
Modelos Teóricos
Sólidos em Suspensão/prevenção & controle
Limites: Animais
Responsável: CL1.1 - Biblioteca Central


  3 / 3 LILACS  
              first record previous record
seleciona
para imprimir
Fotocópia
Id: lil-247526
Autor: Lenardón, Argelia M. L; Lorenzatti, Eduardo A; Enrique, Susana N.
Título: Monitoreo de insecticidas organoclorados y organofosforados en el rio Paraná (Km 600) / Monitoring organochlorine and organophosphorus insecticide in Paraná river
Fonte: Pesticidas;8:57-66, jan.-dez. 1998. mapas, tab, graf.
Idioma: es.
Resumo: Analisa os resíduos de inseticidas organoclorados e organofosforados, na água e materiais em suspensäo de amostras retiradas da Bacia do Rio Paraná (próximo ao Km 600), durante os anos de 1995 e 1996. Verifica o transporte de material em suspensäo e a relaçäo entre o transporte dos inseticidas dissolvidos e adsorvidos. Compara as condiçöes ambientais atuais com dados obtidos nos anos 1983-84. Usa a cromatografia em fase gasosa para as determinaçöes qualitativas e quantitativas dos inseticidas Alfa+gama Hexaclorohexano, Aldrin, heptacloro, Paration metílico. Conclui que as concentraçöes máximas säo obtidas nos meses de primavera e veräo, os quais coincidem com as épocas de aplicaçäo dos inseticidas. Em geral o máximo de inseticidas adsorvidos se apresentam com um "lag" de 60 dias em relaçäo aos dissolvidos. Considerando os limites internacionais estabelecidos para água potável e desenvolvimento da vida aquática, o Rio Paraná (Km600) e suas áreas de influência continuam em condiçöes perigosas para a fauna íctica, embora tenha sido registrada diminuiçäo nos índices de concentraçäo
Descritores: Cromatografia
Inseticidas Organoclorados
Saúde Pública
Sólidos em Suspensão
Resíduos
Água
Responsável: BR16.1 - Biblioteca de Ciências da Saúde



página 1 de 1
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde