[PMID]:28459251
[Au] Autor:Spath A; Smith C
[Ad] Endereço:Lecturer, University of California, Los Angeles, California; Private Practice, Newport Beach, California; Mentor, Kois Center, Seattle, Washington.
[Ti] Título:Removal of Modern Ceramics.
[So] Source:Compend Contin Educ Dent;38(5):326-333, 2017 May.
[Is] ISSN:2158-1797
[Cp] País de publicação:United States
[La] Idioma:eng
[Ab] Resumo:With the overwhelming acceptance of lithium disilicate and zirconia, the frequency with which dentists have to remove these materials is increasing, and this can be difficult. Proper cement usage for full-coverage crowns with preparations that have retention and resistance can be helpful if in the future the restoration needs to be removed. When removing these modern materials, bur and laser techniques are both effective means, with each having specific benefits. Materials selection and preparation design are vital when considering areas of risk each patient exhibits and the potential need for removal.
[Mh] Termos MeSH primário: Cerâmica
Coroas
Materiais Dentários
Porcelana Dentária
Lasers
Zircônio
[Mh] Termos MeSH secundário: Cerâmica/química
Cimentos Dentários/química
Falha de Restauração Dentária
Seres Humanos
[Pt] Tipo de publicação:JOURNAL ARTICLE
[Nm] Nome de substância:
0 (Dental Cements); 0 (Dental Materials); 0 (lithia disilicate); 12001-21-7 (Dental Porcelain); C6V6S92N3C (Zirconium); S38N85C5G0 (zirconium oxide)
[Em] Mês de entrada:1803
[Cu] Atualização por classe:180308
[Lr] Data última revisão:
180308
[Sb] Subgrupo de revista:D
[Da] Data de entrada para processamento:170502
[St] Status:MEDLINE


  2 / 14175 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
[PMID]:29364328
[Au] Autor:Azar B; Eckert S; Kunkela J; Ingr T; Mounajjed R
[Ad] Endereço:Institute of Dentistry and Oral Sciences, Palacky University, Olomouc, Czech Republic.
[Ti] Título:The marginal fit of lithium disilicate crowns: Press vs. CAD/CAM.
[So] Source:Braz Oral Res;32:e001, 2018.
[Is] ISSN:1807-3107
[Cp] País de publicação:Brazil
[La] Idioma:eng
[Ab] Resumo:This study aimed to compare the vertical marginal gap of teeth restored with lithium disilicate crowns fabricated using CAD/CAM or by pressed ceramic approach. Twenty mandibular third molar teeth were collected after surgical extractions and prepared to receive full veneer crowns. Teeth were optically scanned and lithium disilicate blocks were used to fabricate crowns using CAD/CAM technique. Polyvinyl siloxane impressions of the prepared teeth were made and monolithic pressed lithium disilicate crowns were fabricated. The marginal gap was measured using optical microscope at 200× magnification (Keyence VHX-5000, Japan). Statistical analysis was performed using Wilcoxon test. The lithium disilicate pressed crowns had significantly smaller (p = 0.006) marginal gaps (38 ± 12 µm) than the lithium disilicate CAD/CAM crowns (45 ± 12 µm). This research indicates that lithium disilicate crowns fabricated with the press technique have measurably smaller marginal gaps compared with those fabricated with CAD/CAM technique within in vitro environments. The marginal gaps achieved by the crowns across all groups were within a clinically acceptable range.
[Mh] Termos MeSH primário: Projeto Auxiliado por Computador
Coroas/normas
Técnica de Moldagem Odontológica
Adaptação Marginal Dentária/normas
Porcelana Dentária/química
[Mh] Termos MeSH secundário: Materiais para Moldagem Odontológica
Planejamento de Prótese Dentária
Seres Humanos
Teste de Materiais
Padrões de Referência
Valores de Referência
Reprodutibilidade dos Testes
Estatísticas não Paramétricas
[Pt] Tipo de publicação:COMPARATIVE STUDY; JOURNAL ARTICLE
[Nm] Nome de substância:
0 (Dental Impression Materials); 0 (lithia disilicate); 12001-21-7 (Dental Porcelain)
[Em] Mês de entrada:1803
[Cu] Atualização por classe:180307
[Lr] Data última revisão:
180307
[Sb] Subgrupo de revista:D; IM
[Da] Data de entrada para processamento:180125
[St] Status:MEDLINE


  3 / 14175 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
[PMID]:29182215
[Au] Autor:Abdulhameed N; Roulet JF; Chen C; Hussein H
[Ad] Endereço:PhD Student, Clinical Assistant Professor, University of Florida, College of Dentistry, Department of Restorative Dental Sciences, Center for Dental Biomaterials, 1395 Center Drive, Gainesville Fl 32608 USA.
[Ti] Título:A Measurement Protocol for the Marginal and Internal Fit of All-Ceramic Crowns.
[So] Source:Eur J Prosthodont Restor Dent;25(4):193-200, 2017 Dec 01.
[Is] ISSN:0965-7452
[Cp] País de publicação:England
[La] Idioma:eng
[Ab] Resumo:AIMS: To evaluate in vitro the influence of firing on marginal and internal fit of all-ceramic milled and pressed lithium-disilicate crowns. MATERIALS AND METHODS: One Standardized model with 1.6mm occlusal and 1.4mm axial reduction was used to fabricate 64 crowns. Using a factorial design, eight groups of lithium disilicate ceramics (n=8) using P=press, C=CAD/CAM, M=monolithic, O=coping, V=veneered, R=as produced: PMR, PMG, POR, PVG, CMR, CMG, COR, CVG. Crowns were produced and cemented on stone dies, then embedded in clear epoxy resin and sectioned into two plains. With a digital microscope, the distance between die and crowns was measured at the occlusal and axial walls. The horizontal/vertical fit at the finishing line of each section were measured as well. RESULTS: For the marginal fit, the analysis shows that the influence of material and design was significant on horizontal and vertical margins, and the influence of finish was significant with horizontal but not vertical margins (p=0.09). For the internal fit, the analysis showed that the axial gap was significantly influenced by material and finish but not by design (p=0.44). CONCLUSIONS: With a few exceptions, horizontal and vertical marginal discrepancies were below 100 µm. Additional firing increased the discrepancies.
[Mh] Termos MeSH primário: Cerâmica
Coroas
Materiais Dentários
Porcelana Dentária
Ajuste de Prótese/métodos
[Mh] Termos MeSH secundário: Planejamento de Prótese Dentária
[Pt] Tipo de publicação:JOURNAL ARTICLE
[Nm] Nome de substância:
0 (Dental Materials); 0 (lithia disilicate); 12001-21-7 (Dental Porcelain)
[Em] Mês de entrada:1803
[Cu] Atualização por classe:180306
[Lr] Data última revisão:
180306
[Sb] Subgrupo de revista:D
[Da] Data de entrada para processamento:171129
[St] Status:MEDLINE
[do] DOI:10.1922/EJPRD_01735Abdulhameed08


  4 / 14175 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
[PMID]:29292414
[Au] Autor:Schwindling FS; Rammelsberg P; Krisam J; Rues S
[Ti] Título:Adjustment of retention of all-ceramic double-crown attachments.
[So] Source:Int J Comput Dent;20(4):409-421, 2017.
[Is] ISSN:1463-4201
[Cp] País de publicação:England
[La] Idioma:eng
[Ab] Resumo:OBJECTIVES: Double-crown attachments, such as conical crowns (CCs), can retain removable partial prostheses. Digital manufacturing enables the use of innovative materials such as zirconia, and new workflows. The aim of this study was to investigate options for the adjustment of retention forces of all-zirconia CCs. MATERIALS AND METHODS: Single zirconia primary crowns were produced with convergence angles (α) of 3 and 4 degrees, together with monolithic zirconia secondary crowns (n = 8 for α = 3 degrees; n = 8 for α = 4 degrees). Retention was measured by fitting the crowns with forces F = 12.5 to 100 N, and evaluating the magnitudes of the forces required for loosening (L). L/F ratios were recorded, and the coefficient of friction (µ0) was calculated. To limit the maximum force required for loosening, and to prevent high tensile stresses within the crowns, the width of the occlusal gap between the primary and secondary crowns was limited by the implementation of occlusal stops. RESULTS: True convergence angles were more conical than expected, by approximately 0.3 degrees. For α = 3 degrees and α = 4 degrees, L/F ratios were 0.308 (SD 0.04) and 0.208 (SD 0.068), respectively. The overall coefficient of static friction was µ0 = 0.113. Maximum retention forces were successfully controlled; the average values were 12.1 N (SD 4.5 N) for zirconia occlusal stops, and 12.8 N (SD 3.3 N) for composite occlusal stops. CONCLUSION: The clinically desired L/F ratio of 1/3 was achieved by selecting 3-degree burs for fabrication of all-zirconia CCs. It is possible to limit retention, thereby reducing tensile stress in the circumferential direction in secondary crowns.
[Mh] Termos MeSH primário: Coroas
Materiais Dentários
Planejamento de Prótese Dentária
Retenção em Prótese Dentária
Zircônio
[Mh] Termos MeSH secundário: Análise do Estresse Dentário
Seres Humanos
[Pt] Tipo de publicação:JOURNAL ARTICLE
[Nm] Nome de substância:
0 (Dental Materials); C6V6S92N3C (Zirconium); S38N85C5G0 (zirconium oxide)
[Em] Mês de entrada:1802
[Cu] Atualização por classe:180228
[Lr] Data última revisão:
180228
[Sb] Subgrupo de revista:D
[Da] Data de entrada para processamento:180103
[St] Status:MEDLINE


  5 / 14175 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
[PMID]:29188690
[Au] Autor:Ibbetson R; Hemmings K; Harris I
[Ti] Título:Guidelines for Crowns, Fixed Bridges and Implants.
[So] Source:Dent Update;44(5):374-6, 378-80, 382-4, 386, 2017 May.
[Is] ISSN:0305-5000
[Cp] País de publicação:England
[La] Idioma:eng
[Mh] Termos MeSH primário: Coroas
Implantes Dentários
Prótese Parcial Fixa
[Mh] Termos MeSH secundário: Seres Humanos
[Pt] Tipo de publicação:JOURNAL ARTICLE; PRACTICE GUIDELINE
[Nm] Nome de substância:
0 (Dental Implants)
[Em] Mês de entrada:1801
[Cu] Atualização por classe:180130
[Lr] Data última revisão:
180130
[Sb] Subgrupo de revista:D
[Da] Data de entrada para processamento:171201
[St] Status:MEDLINE


  6 / 14175 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
[PMID]:29235779
[Au] Autor:Kurtzman GM; Agarwal T
[Ti] Título:Laser Troughing to Improve Scanning and Impressions.
[So] Source:Dent Today;36(1):122-5, 2017 Jan.
[Is] ISSN:8750-2186
[Cp] País de publicação:United States
[La] Idioma:eng
[Mh] Termos MeSH primário: Coroas
Técnica de Moldagem Odontológica
Técnicas de Retração Gengival/instrumentação
Lasers Semicondutores
[Mh] Termos MeSH secundário: Planejamento de Prótese Dentária
Falha de Restauração Dentária
Feminino
Seres Humanos
Meia-Idade
Preparo Prostodôntico do Dente
[Pt] Tipo de publicação:CASE REPORTS; JOURNAL ARTICLE
[Em] Mês de entrada:1801
[Cu] Atualização por classe:180115
[Lr] Data última revisão:
180115
[Sb] Subgrupo de revista:D
[Da] Data de entrada para processamento:171214
[St] Status:MEDLINE


  7 / 14175 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
[PMID]:29235773
[Au] Autor:Sonick M; Hwang D; Dworkin J
[Ti] Título:Implants in the Aesthetic Zone: Clinical Guidelines.
[So] Source:Dent Today;36(1):91-2, 94-5, 2017 Jan.
[Is] ISSN:8750-2186
[Cp] País de publicação:United States
[La] Idioma:eng
[Mh] Termos MeSH primário: Implantação Dentária Endo-Óssea/métodos
Implantes Dentários para Um Único Dente
Estética Dentária
[Mh] Termos MeSH secundário: Aumento do Rebordo Alveolar/métodos
Transplante Ósseo
Coroas
Feminino
Seres Humanos
Incisivo
Maxila
Sorriso
Extração Dentária
Adulto Jovem
[Pt] Tipo de publicação:CASE REPORTS; JOURNAL ARTICLE
[Em] Mês de entrada:1801
[Cu] Atualização por classe:180115
[Lr] Data última revisão:
180115
[Sb] Subgrupo de revista:D
[Da] Data de entrada para processamento:171214
[St] Status:MEDLINE


  8 / 14175 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
[PMID]:29235763
[Au] Autor:Evans PS
[Ti] Título:Biocompatible Quadrant Dentistry for Overall Health.
[So] Source:Dent Today;36(2):126, 128-9, 2017 Feb.
[Is] ISSN:8750-2186
[Cp] País de publicação:United States
[La] Idioma:eng
[Mh] Termos MeSH primário: Materiais Biocompatíveis/química
Materiais Dentários/química
Restauração Dentária Permanente/métodos
Dentística Operatória/normas
Saúde Holística
[Mh] Termos MeSH secundário: Idoso
Coroas
Eficiência
Feminino
Seres Humanos
Meia-Idade
[Pt] Tipo de publicação:CASE REPORTS; JOURNAL ARTICLE
[Nm] Nome de substância:
0 (Biocompatible Materials); 0 (Dental Materials)
[Em] Mês de entrada:1801
[Cu] Atualização por classe:180115
[Lr] Data última revisão:
180115
[Sb] Subgrupo de revista:D
[Da] Data de entrada para processamento:171214
[St] Status:MEDLINE


  9 / 14175 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
[PMID]:29235759
[Au] Autor:Lowe RA
[Ti] Título:A One-Visit Option: An Alternative to Traditional Ceramic Restorations.
[So] Source:Dent Today;36(2):100, 102, 104, 2017 Feb.
[Is] ISSN:8750-2186
[Cp] País de publicação:United States
[La] Idioma:eng
[Mh] Termos MeSH primário: Coroas
Prótese Adesiva
Preparo Prostodôntico do Dente/métodos
[Mh] Termos MeSH secundário: Adolescente
Dente Pré-Molar/anormalidades
Planejamento de Prótese Dentária
Seres Humanos
Masculino
[Pt] Tipo de publicação:CASE REPORTS; JOURNAL ARTICLE
[Em] Mês de entrada:1801
[Cu] Atualização por classe:180115
[Lr] Data última revisão:
180115
[Sb] Subgrupo de revista:D
[Da] Data de entrada para processamento:171214
[St] Status:MEDLINE


  10 / 14175 MEDLINE  
              first record previous record
seleciona
para imprimir
Fotocópia
[PMID]:29235748
[Au] Autor:Nazarian A
[Ti] Título:Implementing a Systematic Digital Workflow.
[So] Source:Dent Today;36(3):108, 110-1, 2017 Mar.
[Is] ISSN:8750-2186
[Cp] País de publicação:United States
[La] Idioma:eng
[Mh] Termos MeSH primário: Coroas
Implantação Dentária Endo-Óssea/métodos
Implantes Dentários
Prótese Dentária Fixada por Implante
Desgaste dos Dentes/terapia
[Mh] Termos MeSH secundário: Falha de Restauração Dentária
Feminino
Seres Humanos
Meia-Idade
Dimensão Vertical
[Pt] Tipo de publicação:CASE REPORTS; JOURNAL ARTICLE
[Nm] Nome de substância:
0 (Dental Implants)
[Em] Mês de entrada:1801
[Cu] Atualização por classe:180115
[Lr] Data última revisão:
180115
[Sb] Subgrupo de revista:D
[Da] Data de entrada para processamento:171214
[St] Status:MEDLINE



página 1 de 1418 ir para página                         
   


Refinar a pesquisa
  Base de dados : MEDLINE Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde