Base de dados : MEDLINE
Pesquisa : G01.358.500 [Categoria DeCS]
Referências encontradas : 5445 [refinar]
Mostrando: 1 .. 10   no formato [Detalhado]

página 1 de 545 ir para página                         

  1 / 5445 MEDLINE  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo
[PMID]:28448876
[Au] Autor:Sebesta F; Burda JV
[Ad] Endereço:Department of Chemical Physics and Optics, Faculty of Mathematics and Physics, Charles University, Ke Karlovu 3, 121 16 Prague 2, Czech Republic.
[Ti] Título:Study on electronic properties, thermodynamic and kinetic parameters of the selected platinum(II) derivatives interacting with guanine.
[So] Source:J Inorg Biochem;172:100-109, 2017 Jul.
[Is] ISSN:1873-3344
[Cp] País de publicação:United States
[La] Idioma:eng
[Ab] Resumo:Interaction of hydrated forms of several potential anticancer agents (PtCl (diaminocyclohexane), trans-[PtCl (NH )(thiazole)], cis-[PtCl (NH )(piperidine)], and cis-PtCl (NH )(cyclohexylamine) complexes) with guanine are explored and compared with an analogous interaction of cisplatin. Basic electronic properties, binding and stabilization energies are determined and energy profiles for the aquation reaction are estimated at the B3LYP/6-311++G(2df,2pd) level of theory. It is found that the substitution reaction is an exothermic and exergonic process with ΔG slightly less negative than -20kcal/mol. The largest energy release occurs for PtCl(H O)(diaminocyclohexane) complex. The rate constants for the Pt(II) complexes in the chloro- and hydroxo-form are compared and an impact of the ligand in the trans position to water is discussed.
[Mh] Termos MeSH primário: Fenômenos Eletromagnéticos
Guanina/química
Platina/química
Termodinâmica
[Mh] Termos MeSH secundário: Antineoplásicos/química
Cinética
Compostos Organoplatínicos/química
[Pt] Tipo de publicação:JOURNAL ARTICLE
[Nm] Nome de substância:
0 (Antineoplastic Agents); 0 (Organoplatinum Compounds); 49DFR088MY (Platinum); 5Z93L87A1R (Guanine)
[Em] Mês de entrada:1802
[Cu] Atualização por classe:180220
[Lr] Data última revisão:
180220
[Sb] Subgrupo de revista:IM
[Da] Data de entrada para processamento:170428
[St] Status:MEDLINE


  2 / 5445 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
[PMID]:29368461
[Au] Autor:Steigerwald J
[Ti] Título:The Subject as Instrument: Galvanic Experiments, Organic Apparatus and Problems of Calibration.
[So] Source:Clio Med;95:80-110, 2016.
[Is] ISSN:0045-7183
[Cp] País de publicação:Netherlands
[La] Idioma:eng
[Mh] Termos MeSH primário: Calibragem
Desenho de Equipamento/história
Resposta Galvânica da Pele
Experimentação Humana/história
Neurofisiologia/história
[Mh] Termos MeSH secundário: Fenômenos Eletromagnéticos
História do Século XVIII
História do Século XIX
Seres Humanos
[Pt] Tipo de publicação:HISTORICAL ARTICLE; JOURNAL ARTICLE
[Em] Mês de entrada:1802
[Cu] Atualização por classe:180215
[Lr] Data última revisão:
180215
[Sb] Subgrupo de revista:IM; QIS
[Da] Data de entrada para processamento:180126
[St] Status:MEDLINE


  3 / 5445 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
[PMID]:29368460
[Au] Autor:Iliffe R
[Ti] Título:Galvanic Humans.
[So] Source:Clio Med;95:52-79, 2016.
[Is] ISSN:0045-7183
[Cp] País de publicação:Netherlands
[La] Idioma:eng
[Mh] Termos MeSH primário: Resposta Galvânica da Pele
Experimentação Humana/história
Neurofisiologia/história
[Mh] Termos MeSH secundário: Estimulação Elétrica
Fenômenos Eletromagnéticos
História do Século XVIII
História do Século XIX
Seres Humanos
[Pt] Tipo de publicação:HISTORICAL ARTICLE; JOURNAL ARTICLE
[Em] Mês de entrada:1802
[Cu] Atualização por classe:180215
[Lr] Data última revisão:
180215
[Sb] Subgrupo de revista:IM; QIS
[Da] Data de entrada para processamento:180126
[St] Status:MEDLINE


  4 / 5445 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
[PMID]:29391121
[Au] Autor:Shadid H; Keckeisen M; Zarrinpar A
[Ad] Endereço:Department of Surgery, University of Florida Health Science Center, Gainesville, Florida, USA.
[Ti] Título:Safety and Efficacy of Electromagnetic-Guided Bedside Placement of Nasoenteral Feeding Tubes Standard Placement.
[So] Source:Am Surg;83(10):1184-1187, 2017 Oct 01.
[Is] ISSN:1555-9823
[Cp] País de publicação:United States
[La] Idioma:eng
[Ab] Resumo:Although enteral feeding in critically ill patients has been shown to be beneficial, reliable postpyloric placement of feeding tubes remains a challenge. The standard of care involves blind placement, frequently requiring multiple attempts, and radiographs. To evaluate the effect of electromagnetic-guided bedside placement in reducing time to establishment of feeding, lung placement, use of radiography, and cost, we initiated a prospective trial using electromagnetic-guided bedside placement and compared them to a retrospective cohort. Fifty-three consecutive placements of nasoenteral feeding tubes were made using electromagnetic-guidance on patients requiring enteral nutrition in a surgical intensive care unit at a tertiary care center. Sixty-three placement attempts in the preceding seven months served as controls. There were no significant differences between the two groups in terms of age, sex, weight, body mass index, hiatal or ventral hernias, or previous esophageal/gastric operations. The number of radiographs needed per patient, need for fluoroscopy, radiology charge per patient for the tube placement, and time from first attempt at placement to confirmation of postpyloric location were lower for the electromagnetic-guided group. Use of electromagnetic guidance allows reliable and cost-effective postpyloric enteral feeding tube placement compared with blind insertion.
[Mh] Termos MeSH primário: Cuidados Críticos/métodos
Fenômenos Eletromagnéticos
Nutrição Enteral/métodos
Intubação Gastrointestinal/métodos
[Mh] Termos MeSH secundário: Adulto
Idoso
Estado Terminal
Feminino
Seres Humanos
Masculino
Meia-Idade
Avaliação de Resultados (Cuidados de Saúde)
Segurança do Paciente
Estudos Prospectivos
Melhoria de Qualidade
Radiografia
[Pt] Tipo de publicação:CLINICAL TRIAL; COMPARATIVE STUDY; JOURNAL ARTICLE
[Em] Mês de entrada:1802
[Cu] Atualização por classe:180214
[Lr] Data última revisão:
180214
[Sb] Subgrupo de revista:IM
[Da] Data de entrada para processamento:180203
[St] Status:MEDLINE


  5 / 5445 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
[PMID]:29303350
[Au] Autor:Dierckx H; Biktasheva IV; Verschelde H; Panfilov AV; Biktashev VN
[Ad] Endereço:Department of Physics and Astronomy, Ghent University, 9000 Ghent, Belgium.
[Ti] Título:Filament Tension and Phase Locking of Meandering Scroll Waves.
[So] Source:Phys Rev Lett;119(25):258101, 2017 Dec 22.
[Is] ISSN:1079-7114
[Cp] País de publicação:United States
[La] Idioma:eng
[Ab] Resumo:Meandering spiral waves are often observed in excitable media such as the Belousov-Zhabotinsky reaction and cardiac tissue. We derive a theory for drift dynamics of meandering rotors in general reaction-diffusion systems and apply it to two types of external disturbances: an external field and curvature-induced drift in three dimensions. We find two distinct regimes: with small filament curvature, meandering scroll waves exhibit filament tension, whose sign determines the stability and drift direction. In the regimes of strong external fields or meandering motion close to resonance, however, phase locking of the meander pattern is predicted and observed.
[Mh] Termos MeSH primário: Simulação por Computador
Fenômenos Eletromagnéticos
Coração
Movimento (Física)
[Mh] Termos MeSH secundário: Citoesqueleto
Difusão
Modelos Cardiovasculares
[Pt] Tipo de publicação:JOURNAL ARTICLE
[Em] Mês de entrada:1802
[Cu] Atualização por classe:180206
[Lr] Data última revisão:
180206
[Sb] Subgrupo de revista:IM
[Da] Data de entrada para processamento:180106
[St] Status:MEDLINE
[do] DOI:10.1103/PhysRevLett.119.258101


  6 / 5445 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
[PMID]:29269461
[Au] Autor:Dalton CA
[Ad] Endereço:Department of Earth, Environmental and Planetary Sciences, Brown University, Providence, RI, USA. colleen_dalton@brown.edu.
[Ti] Título:How seismic waves lose energy.
[So] Source:Science;358(6370):1536-1537, 2017 12 22.
[Is] ISSN:1095-9203
[Cp] País de publicação:United States
[La] Idioma:eng
[Mh] Termos MeSH primário: Fenômenos Eletromagnéticos
Fenômenos Físicos
[Mh] Termos MeSH secundário: Acústica
Ondas de Rádio
Ondas de Maré
Vibração
[Pt] Tipo de publicação:JOURNAL ARTICLE; COMMENT
[Em] Mês de entrada:1712
[Cu] Atualização por classe:171227
[Lr] Data última revisão:
171227
[Sb] Subgrupo de revista:IM
[Da] Data de entrada para processamento:171223
[St] Status:MEDLINE
[do] DOI:10.1126/science.aar2748


  7 / 5445 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
[PMID]:28934238
[Au] Autor:Götz TI; Lahmer G; Strnad V; Bert C; Hensel B; Tomé AM; Lang EW
[Ad] Endereço:CIML, Biophysics, University of Regensburg, 93040 Regensburg, Germany.
[Ti] Título:A tool to automatically analyze electromagnetic tracking data from high dose rate brachytherapy of breast cancer patients.
[So] Source:PLoS One;12(9):e0183608, 2017.
[Is] ISSN:1932-6203
[Cp] País de publicação:United States
[La] Idioma:eng
[Ab] Resumo:During High Dose Rate Brachytherapy (HDR-BT) the spatial position of the radiation source inside catheters implanted into a female breast is determined via electromagnetic tracking (EMT). Dwell positions and dwell times of the radiation source are established, relative to the patient's anatomy, from an initial X-ray-CT-image. During the irradiation treatment, catheter displacements can occur due to patient movements. The current study develops an automatic analysis tool of EMT data sets recorded with a solenoid sensor to assure concordance of the source movement with the treatment plan. The tool combines machine learning techniques such as multi-dimensional scaling (MDS), ensemble empirical mode decomposition (EEMD), singular spectrum analysis (SSA) and particle filter (PF) to precisely detect and quantify any mismatch between the treatment plan and actual EMT measurements. We demonstrate that movement artifacts as well as technical signal distortions can be removed automatically and reliably, resulting in artifact-free reconstructed signals. This is a prerequisite for a highly accurate determination of any deviations of dwell positions from the treatment plan.
[Mh] Termos MeSH primário: Braquiterapia/instrumentação
Neoplasias da Mama/radioterapia
Cateteres
Fenômenos Eletromagnéticos
Dose de Radiação
[Mh] Termos MeSH secundário: Idoso
Automação
Neoplasias da Mama/diagnóstico por imagem
Feminino
Seres Humanos
Processamento de Imagem Assistida por Computador
Masculino
Meia-Idade
Movimento (Física)
Imagens de Fantasmas
Dosagem Radioterapêutica
Planejamento da Radioterapia Assistida por Computador
Tomografia Computadorizada por Raios X
[Pt] Tipo de publicação:JOURNAL ARTICLE
[Em] Mês de entrada:1710
[Cu] Atualização por classe:171018
[Lr] Data última revisão:
171018
[Sb] Subgrupo de revista:IM
[Da] Data de entrada para processamento:170922
[St] Status:MEDLINE
[do] DOI:10.1371/journal.pone.0183608


  8 / 5445 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
[PMID]:28870923
[Au] Autor:Wikstrom J; Isacsson U; Johansson B; Lennernäs BO
[Ad] Endereço:Department of Surgical Sciences, Section of Radiology, Uppsala University, Uppsala, Sweden.
[Ti] Título:Magnetic Resonance Compatibility of a Transponder Aimed for Radiotherapy Positioning - A Phantom Study.
[So] Source:Anticancer Res;37(9):4993-4996, 2017 09.
[Is] ISSN:1791-7530
[Cp] País de publicação:Greece
[La] Idioma:eng
[Ab] Resumo:BACKGROUND/AIM: Electromagnetic Positioning Systems (EMP) is a new position-ing technique in four-dimensional radiotherapy. Patients with implanted transponders may be referred for magnetic resonance imaging (MRI) making it important to establish the MR safety. MATERIALS AND METHODS: Oranges were prepared with transponders and imaged on a 3T MR scanner with different sequences. Computed tomography (CT) was performed as comparison. MR artifacts were assessed. An estimation of the maximum transponder de-flection force and heating was made. RESULTS: The mean measured displacement of transponders was 0.1 mm (range=0.03-0.3 mm). Artifacts were observed adjacent to transponders using all sequences. The deflection force on the transponder in the gantry was less than 38 mN. No heating was observed. CONCLUSION: The absence of any substantial movement, the weak measured deflection force and absence of observed heating speaks for the safe use of MR imaging with transponder 3T. Local artefacts makes evaluation impossible adjacent to transponders.
[Mh] Termos MeSH primário: Citrus sinensis
Imagem por Ressonância Magnética/métodos
Imagens de Fantasmas
Neoplasias da Próstata/radioterapia
Planejamento da Radioterapia Assistida por Computador/métodos
Terapia Assistida por Computador/instrumentação
[Mh] Termos MeSH secundário: Fenômenos Eletromagnéticos
Seres Humanos
Masculino
Movimento
Tomografia Computadorizada por Raios X/métodos
[Pt] Tipo de publicação:JOURNAL ARTICLE
[Em] Mês de entrada:1710
[Cu] Atualização por classe:171025
[Lr] Data última revisão:
171025
[Sb] Subgrupo de revista:IM
[Da] Data de entrada para processamento:170906
[St] Status:MEDLINE


  9 / 5445 MEDLINE  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
[PMID]:28807088
[Au] Autor:Dönmez D; Giotakis E; Hosemann WG; Kühnel TS; Hirt B; Weber RK
[Ad] Endereço:Department of Otorhinolaryngology,Municipal Hospital of Karlsruhe,Germany.
[Ti] Título:Posterior translacrimal approach to the maxillary sinus.
[So] Source:J Laryngol Otol;131(10):871-879, 2017 Oct.
[Is] ISSN:1748-5460
[Cp] País de publicação:England
[La] Idioma:eng
[Ab] Resumo:BACKGROUND: This study aimed to compare the view into the maxillary sinus using the posterior translacrimal approach compared with grade 3 antrostomy. METHODS: Grade 3 antrostomy followed by a posterior translacrimal approach was performed on four cadavers. The maximum intramaxillary view was documented endoscopically guided by electromagnetic navigation. Representative screenshots were evaluated in a blinded manner by three independent sinus surgeons. In addition, a prospective investigation of specific complications in the post-operative course of consecutive patients was performed. RESULTS: In the cadaver study, the posterior translacrimal approach provided a significantly better view into the maxillary sinus compared with grade 3 antrostomy. In the clinical study, only 1 out of 20 patients reported on a minor problem with lacrimal drainage at 6 months. CONCLUSION: The posterior translacrimal approach to visualising the maxillary sinus should be considered a strong alternative to more radical techniques.
[Mh] Termos MeSH primário: Procedimentos Cirúrgicos Otorrinolaringológicos/métodos
Doenças dos Seios Paranasais/diagnóstico por imagem
Doenças dos Seios Paranasais/cirurgia
[Mh] Termos MeSH secundário: Cadáver
Fenômenos Eletromagnéticos
Endoscopia
Feminino
Seres Humanos
Masculino
Estudos Prospectivos
Tomografia Computadorizada por Raios X
Resultado do Tratamento
[Pt] Tipo de publicação:COMPARATIVE STUDY; JOURNAL ARTICLE
[Em] Mês de entrada:1710
[Cu] Atualização por classe:171010
[Lr] Data última revisão:
171010
[Sb] Subgrupo de revista:AIM; IM
[Da] Data de entrada para processamento:170816
[St] Status:MEDLINE
[do] DOI:10.1017/S0022215117001621


  10 / 5445 MEDLINE  
              first record previous record
seleciona
para imprimir
Fotocópia
Texto completo
[PMID]:28800823
[Au] Autor:Fernández P; Gabaldón JA; Periago MJ
[Ad] Endereço:Department of Food Technology, Food Science and Nutrition, Faculty of Veterinary Sciences, Regional Campus of International Excellence "Campus Mare Nostrum", University of Murcia, Espinardo 30071, Murcia, Spain.
[Ti] Título:Detection and quantification of Alicyclobacillus acidoterrestris by electrical impedance in apple juice.
[So] Source:Food Microbiol;68:34-40, 2017 Dec.
[Is] ISSN:1095-9998
[Cp] País de publicação:England
[La] Idioma:eng
[Ab] Resumo:Alicyclobacillus acidoterrestris is a thermotolerant bacterium able to grow in fruit juices and drinks, as the spoilage by Alicyclobacillus in the final product does not product any gas, but leads to a "medicine flavor" due to the formation of guaicol. Also, its detection is a challenge for the quality control departments, because it takes several days to get the results of traditional microbiology methods. This study aimed at developing a more accurate electrical impedance technique for the detection of A. acidoterrestris in concentrated apple juice. Samples of apple juice were inoculated with A. acidoterrestris spores isolated from a peach and grape juice. For the spore germination, several heat-shock treatments were tested (80 °C/10 min, 70 °C/20 min and 60 °C/30 min). Direct and indirect electrical impedance was applied to detect and quantify the microorganism in the inoculated apple juice, using BAT broth and Bimedia 002A (pH 4). The 80 °C/10 min treatment was selected for spore activation. The valid electrical impedance technique was the indirect method in BAT broth, which measured the changes in the impedance through the formation of CO . In addition, a positive correlation (r = 0.98, R = 0.97) was observed between the classical microbiology (BAM agar) and the indirect impedance method.
[Mh] Termos MeSH primário: Bacillales/isolamento & purificação
Técnicas Eletroquímicas/métodos
Sucos de Frutas e Vegetais/microbiologia
Malus/microbiologia
[Mh] Termos MeSH secundário: Bacillales/química
Bacillales/crescimento & desenvolvimento
Impedância Elétrica
Fenômenos Eletromagnéticos
Sucos de Frutas e Vegetais/análise
Malus/química
[Pt] Tipo de publicação:EVALUATION STUDIES; JOURNAL ARTICLE
[Em] Mês de entrada:1710
[Cu] Atualização por classe:171016
[Lr] Data última revisão:
171016
[Sb] Subgrupo de revista:IM
[Da] Data de entrada para processamento:170813
[St] Status:MEDLINE



página 1 de 545 ir para página                         
   


Refinar a pesquisa
  Base de dados : MEDLINE Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde