Base de dados : BBO
Pesquisa : G01.374.618 [Categoria DeCS]
Referências encontradas : 24 [refinar]
Mostrando: 1 .. 10   no formato [Longo]

página 1 de 3 ir para página          

  1 / 24 BBO  
              next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: 44886
Autor: s. afFranzão, Bruno Franco; Universidade Católica de BrasíliaCastro, Adriano Gonçalves Barbosa de; Universidade Católica de BrasíliaPiau, Cinthia Gonçalves Barbosa de Castro; Faculdades Integradas da União Educacional do Planalto CentralDobranszki, Adriano.
Título: Aparelhos autoligados e convencionais: Uma análise crítica / Self-ligating and conventional appliances: a critical analysis
Fonte: ROPLAC;4(1):15-22, jan. 2014. tab.
Idioma: pt.
Resumo: Este artigo teve por finalidade fazer um estudo comparativo entre os aparelhos ortodônticos convencionais eautoligados, suprindo os profissionais da área com informações que lhes permitam decidir qual modelo utilizarem cada caso clínico. O artigo se desenvolveu a partir da controvérsia que se criou quanto à eficácia e àeficiência dos tratamentos ortodônticos realizados com aparelhos autoligados, quando comparados aostratamentos com os aparelhos convencionais. Tal controvérsia refere-se aos aspectos da eficiência, do confortoe da relação custo-benefício de cada um desses tipos de aparelhos. Assim, este artigo buscou analisarcriticamente, à luz da literatura científica atual, os aspectos positivos e negativos da utilização de cada umdesses aparelhos, bem como sua adequada indicação aos casos clínicos. O tipo metodológico empregado foi apesquisa aplicada, com método hipotético-dedutivo, abordagem quantitativa, objetivo exploratório, eprocedimento de levantamento bibliográfico e documental. Por fim, o trabalho conclui que cada tipo deaparelho ortodôntico tem uma indicação específica, a depender das necessidades pessoais e clínicas de cadapaciente e do sistema de cobrança do profissional (AU)

The aim of this article was to compare conventional and self-ligating orthodontic appliances, providingprofessionals of this area information to help them decide which system to use in each clinical case. The articlewas developed from the controversy created about the efficiency and the effectiveness of the orthodontictreatments performed with self-ligating appliances when compared to the treatment with conventionalappliances. Such controversy refers to the aspects of efficiency, comfort and cost-effectiveness of each of thesesystems. Thus, this article aimed to critically analyze, in the light of current scientific literature, the positive andnegative aspects of the utilization and the indication of each orthodontic appliance type in the clinical cases.The method type used was the applied research, with hypothetical-deductive method, quantitative approach,with exploratory objective and bibliographic listing procedure and documentary. We concluded that each typeof orthodontic appliance has a specific indication, depending on the clinical and personal necessities of eachpatient and of the professional billing system (AU)
Responsável: BR1264.1 - Biblioteca Setorial Prof Alberto M Campos
BR1264.1


  2 / 24 BBO  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: 43443
Autor: Piva, Luana Caroline.
Título: Avaliação do coeficiente de atrito entre braquetes cerâmicos convencionais e os autoligados / Friction coeficient assessment between conventional and ceramic bracktes self-ligating.
Fonte: Londrina; s.n; 2015. 57 fls p. ilus, tab.
Idioma: pt.
Tese: Apresentada a Universidade Estadual de Londrina. Centro de Ciências da Saúde para obtenção do grau de Especialista.
Resumo: A evolução nos materiais e técnicas na Ortodontia procura auxiliar, facilitar e aprimorar os tratamentos. Neste sentido, os braquetes com sistema autoligado surgiram da busca por um sistema que produzisse uma baixa resistência friccional, facilitando a movimentação dentária. Os braquetes cerâmicos surgiram com a finalidade de melhorar a estética dos aparelhos ortodônticos, no entanto, a resistência friccional produzida parece ser maior do que nos braquetes convencionais metálicos. Desta forma, o objetivo desse trabalho foi verificar a resistência friccional entre os braquetes cerâmicos autoligados e braquetes cerâmicos convencionais associados à ligadura elástica. Para a realização do experimento foram utilizados 15 braquetes autoligados e 15 braquetes convencionais. Os corpos de prova foram confeccionados utilizando um braquete colado em uma placa de vidro de microscopia, contendo tubos metálicos de segundo molar superior em cada extremidade, associados a um segmento de 10cm de fio retangular 0,019"x0,025" que possuía um helicóide em uma das pontas para permitir o tracionamento. O fio era tracionado pelo conjunto tubo/braquete/tubo por uma máquina que registrava em um tensionamento digital o atrito gerado. Os dados foram analisados utilizando o teste "t" de "Student" com nível de significância de 5%. A partir dos resultados encontrados, pôde-se concluir que os braquetes cerâmicos convencionais associados a ligaduras elásticas apresentam maior atrito quando comparados aos braquetes cerâmicos autoligados. (AU)
Responsável: BR510.1 - Biblioteca Setorial da Clínica Odontológica


  3 / 24 BBO  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: 43442
Autor: Lima, Mariana Nunes Lyra.
Título: Avaliação do atrito produzido entre braquetes metálicos convencionais e autoligados ativos / Evolution of friction produced between active metal self-lligating brackets and conventional brackets.
Fonte: Londrina; s.n; 2015. 47 fls p. ilus, tab.
Idioma: pt.
Tese: Apresentada a Universidade Estadual de Londrina. Centro de Ciências da Saúde para obtenção do grau de Especialista.
Resumo: O presente trabalho teve como objetivo verificar se haveria na resistência friccional produzida entre os braquetes metálicos autoligados e os convencionais associados à ligadura elástica. Foram confeccionados trinta corpos de prova, sendo metade composta pro braquetes autoligados e o restante pelos convencionais. Cada corpo de prova era composto por um braquete e dois tubos metálicos alinhados, colados com resina composta em uma placa de vidro de microscopia a uma distância de 10mm entre eles. Para cada corpo de prova, uma secção de 8 cm de fio ortodôndtico 0.019" X 0.025" de aço inoxidável, contendo um helicóide em uma das extremidades era confeccionada, encaixada nos braquetes e, no caso dos braquetes convencionais, amarradas com ligadura elástica. Os fios eram então tracionados por uma máquina para ensaios de tração e os valores da carga máxima necessária para produzir o seu deslizamento, registrados. Os dados foram submetidos a tratamento estatístico, podendo-se concluir que houve diferença estatisticamente significante na resistência fricional, sendo esta menor nos braquetes autoligados do que nos convencionais. (AU)
Responsável: BR510.1 - Biblioteca Setorial da Clínica Odontológica


  4 / 24 BBO  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: 42460
Autor: Geremia, Jean Rafael; Oliveira, Pablo Santos de; Motta, Rogério Heládio Lopes.
Título: Comparação da força de atrito entre bráquetes autoligados e bráquetes convencionais com diferentes ligaduras / Comparison of friction among self-ligating brackets and conventional brackets with different ligadures
Fonte: Ortho Sci., Orthod. sci. pract;8(29):30-37, 2015. ilus, graf.
Idioma: pt.
Resumo: O objetivo do presente trabalho foi comparar a força máxima, força de atrito estática e dinâmica existente entre bráquetes de aço inoxidável autoligados passivos da marca EasyClip® (Aditek®), bráquetes de aço inoxidável convencionais Morelli® (Dental Morelli®) ligados com ligaduras elastoméricas convencionais (Dental Morelli®) e com ligaduras elastoméricas não convencionais com desenhos “8” e “88” (Tecnident®). Foi utilizado um dispositivo que permite a movimentação de deslize do fio (aço inoxidável 0,019 X 0,025 polegadas - Morelli®) de forma perpendicular aos slots dos bráquetes alinhados, sem nenhuma possível interferência externa. Uma máquina de testes universal (EMIC DL2000) foi utilizada para o tracionamento dos fios e transformação em dados computadorizados. Esses dados foram transformados e submetidos aos testes de Kolmogorov & Smirnov, e ao teste de Bartlett, depois submetidos às análises não paramétricas Kruskal-Wallis e SNK. Nesse estudo, bráquetes autoligados e bráquetes convencionais com elásticos não convencionais “8” e “88” reduzem o atrito na mecânica de deslize em relação aos módulos elastoméricos convencionais (P<.05).(AU)

The aim of the present work was to compare maximum force, static and dynamic friction forces between three different types of brackets: passive stainless steel self-ligating brackets from EasyClip® (Aditek®), conventional Morelli® stainless steel brackets (Dental Morelli®) ligated with conventional elastometric ligatures (Dental Morelli®), and with nonconventional elastomeric ligatures “8” and“88” (Tecnident®). A device that allows the slippage of the wire (stainless steel 0.019 X 0.025 inches - Morelli®) perpendicular to the slots of the aligned brackets with no external interference. A universal testing machine (EMIC DL2000) was used to traction the wire and convert it intocomputerized data. These data were submitted to Kolmogorov & Smirnov tests and to Bartlett test, and then to Nonparametric Tests-Kruskal-Wallis and SNK tests. In the present study it was observed that selfligated brackets and conventional brackets with nonconventional “8” and “88” elastics reduce the friction of sliding mechanics when compared to conventional elastometric modules (P<.05). (AU)
Responsável: BR243.1 - Serviço Técnico de Biblioteca e Documentação
Br243.1


  5 / 24 BBO  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Id: 41070
Autor: Beltrán, Mauricio Clavijo; Clavijo, Veronica Beltrán.
Título: Procedimentos peri-implantares minimamente invasivos para a obtenção de estética no perfil transmucoso / Minimally invasive peri-implant procedures to obtain esthetics in the transmucosal profile
Fonte: Dent. press implantol;7(2):81-90, Apr.-June 2013. ilus.
Idioma: pt.
Resumo: Introdução: técnicas de enxerto de tecido conjuntivo são amplamente empregadas durante e previamente a colocação e reabilitação de implantes para a obtenção de resultados estéticos satisfatórios. Contudo, essas técnicas cirúrgicas não são as únicas opções para a correção de deficiências de volume tecidual. Objetivo: mostrar, por meio de um caso clínico, a extrusão ortodôntica lenta, a incisão semilunar durante a fase de reabertura e a utilização da resina composta fluída para o condicionamento tecidual em três etapas: no pôntico ogival, no cicatrizador de polímero e na coroa provisória sobre implante. Resultados: a extrusão ortodôntica lenta promoveu um melhor nivelamento na altura do colo gengival. A incisão semilunar mostrou-se um procedimento que favorece o deslocamento de tecido mucoso para vestibular e a preservação das papilas adjacentes. A resina composta fluída apresentou-se como um material de fácil manuseio e de bom polimento, o que contribuiu para a obtenção de um perfil transmucoso adequado para a coroa sobre implante. Conclusão: concluímos que, após acompanhamento clínico de um ano, esses procedimentos combinados auxiliam na conquista de resultados peri-implantares estéticos e contribuem para a prática da Implantodontia minimamente invasiva.(AU)

Introduction: Connective tissue graft techniques are widely used previously and during the dental implant treatment to obtain satisfactory aesthetic results. However surgical techniques are not the only options for correcting tissue volume deficiencies. The aim of this article is to show, by a clinical case, the prior orthodontic extrusion, the semilunar incision during the implant second surgical stage and the use of composite resin flow for soft tissue conditioning in the ovate pontic, the polymer healing abutment and the provisional crown on the implant. The orthodontic extrusion promoted a better leveling in the gingival collar height. The semilunar incision favored the displacement of the buccal mucosal tissue and the preservation of adjacent papillae. The composite resin flow is a easy handling material and have a good polishing, which contributed to obtain a appropriate transmucosal profile. We concluded, after 1 year of clinical follow-up, that the combined procedures aided to gain aesthetic periimplant results and contributed to thepractice of a minimally invasive implantology.(AU)
Responsável: BR1366.1 - Serviço de Bibliotecas Biomédicas B - Odontologia e Enfermagem
BR1366.1


  6 / 24 BBO  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: 41008
Autor: Clavijo, Victor Grover Rene.
Título: Resistência a extrusão de retentores intra-radiculares de fibra de vidro avaliando: técnica de confecção e cimento resinoso / Resistance to extrusion of intracanal retainers fiberglass evaluated: technical preparation and resin cement.
Fonte: Araraquara; s.n; 2011. 150 p. ilus.
Idioma: pt.
Tese: Apresentada a Universidade Estadual Paulista. Faculdade de Odontologia para obtenção do grau de Doutor.
Resumo: Neste estudo avaliou-se a resistência ao cisalhamento por extrusão de pinos de fibra de vidro, reembasados ou não com compósito, cimentados com dois tipos de cimentos resinosos em dentina intra-radicular, avaliando os segmentos cervical, médio e apical. Selecionaram-se 40 incisivos bovinos com dimensões semelhantes, removendo a porção coronária, padronizando o comprimento das raízes em 14 mm. Após, incluiu-se as raízes em resina acrílica, realizando tratamento endodôntico e, então o preparo dos espaços para os pinos, dividindo- as, em seguida, aleatoriamente em quatro grupos com dez amostras cada. Os elementos do grupo 1 receberam retentores de fibra de vidro cimentados com cimento resinoso RelyX ARC, grupo 2 retentores de fibra de vidro cimentados com cimento resinoso RelyX U100, grupo 3 retentores de fibra de vidro reembasados com resina composta e cimentados com cimento resinoso RelyX ARC e grupo 4 retentores de fibra de vidro reembasados com resina composta e cimentados com cimento resinoso RelyX U100. Ao término dos procedimentos de cimentação, realizou-se a secção dos segmentos radiculares, submetendo, então, os corpos-de-prova ao teste push-out em máquina de ensaios universal, através de ponta ativa cilíndrica com 1 mm de diâmetro, à velocidade de 0,5 mm/min, até extrusão do retentor. Obteve-se os seguintes valores médios de resistência de união, em MPa: grupo 1, terços cervical = 6,22 ± 2,64(a), médio = 4,25 ± 2,01(a) e apical = 4,45± 2,81(a); grupo 2, terços cervical = 5,04 ± 2,34(a), médio = 3,06 ± 2,12(a) e apical = 3,26 ± 2,38(a). grupo 3, terços cervical = 11,85 ± 1,67(b), médio = 11,83 ± 3,84(b) e apical = 10,39 ± 2,44(b). grupo 4, terços cervical = 12,05 ± 1,14(b), médio = 11,98 ± 3,23(b) e apical = 10,96 ± 2,14(b). Submeteram-se os valores à análise de variância e ao teste de Tukey com nível de significância de 5% indicadas... (AU)

This study evaluated the bond strength of fiber posts, relined or not with composite resin, luted with resinous cement to radicular dentin, evaluating cervical, median and apical root segments. Fourty bovine incisors, with similar dimensions, were selected and cut 16 mm from the apical limit. The roots were embedded in acrylic resin and the radicular canals were root treated and post space prepared with a depth of 9 mm. Samples were randomly assigned to two groups of ten roots each. Group 1 received glass fiber posts luted with dual-cure resin cement RelyX ARC in association with a bonding system. In Group 2 the same type of posts were relined with composite for further cementation with resin cement RelyX U100. In Group 3, glass fiber post were relined with composite and cemented with resin cement RelyX ARC and in Group 4 glass fiber posts were relined ith composite and cemented with resin cement RelyX U100. After cementation procedures roots were sectioned transversally and three sections, from cervical, medium and apical thirds were obtained. Push-out test was performed in a universal testing machine with a 1 mm diameter steel rod at cross-head speed of 0,5 mm/min until post extrusion. Collected data was statistically analyzed by two- way ANOVA and Tukey HSD test (p<0,05). The measured retention strengths for cervical, medium and apical thirds were: Group 1, cervical thirds = 6,22 ± 2,64(a), medium = 4,25 ± 2,01(a) e apical = 4,45± 2,81(a); group 2, cervical thirds = 5,04 ± 2,34(a), medium = 3,06 ± 2,12(a) and apical = 3,26 ± 2,38(a). Group 3, cervical thirds = 11,85 ± 1,67(b), medium = 11,83 ± 3,84(b) and apical = 10,39 ± 2,44(b). Group 4, cervical thirds = 12,05 ± 1,14(b), medium = 11,98 ± 3,23(b) and apical = 10,96 ± 2,14(b). Glass fiber composite relined posts presented statistically higher retention values in cervical, medium and apical thirds when compared... (AU)
Responsável: BR39.2 - Biblioteca Professora Maria Dilma de Oliveira Gonçalves
BR39.2


  7 / 24 BBO  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: 40700
Autor: Jaber, Laura Cavalcante Lima.
Título: Degradação de fios ortodônticos sob condições que simulam desafios cariogênicos e erosivos / Study of the elastic properties of silicones addition and condensation through a elasticimeter.
Fonte: Campinas, SP; s.n; 2012. 80 p. ilus.
Idioma: pt.
Tese: Apresentada a Centro de Pesquisas Odontológicas São Leopoldo Mandic para obtenção do grau de Mestre.
Resumo: Este trabalho verificou o efeito de desafios cariogênicos (DCs) e erosivos (DEs) na degradação de fios ortodônticos fabricados em liga de cobre-níquel-titânio (CuNiTi), por meio da mensuração da rugosidade e de fotomicrografias obtidas em microscópio de força atômica (MFA). Em adição, avaliou-se a força de atrito estabelecida entre braquetes autoligados passivos e os referidos fios após terem sido expostos a DCs e DEs. Sessenta segmentos de fios foram distribuídos em quatro grupos, para serem submetidos a DCs ou DEs, que simularam seu uso clínico por 12 semanas, para serem expostos à saliva artificial ou para integrarem o grupo controle (sem tratamento). Os DCs foram realizados com solução desmineralizante (pH 4,3), empregada em modelos físico-químicos de cárie, sendo que os fios foram a ela expostos por 24 horas, por 21 dias. Para simular condição de alto DE, realizou-se a imersão dos fios em solução de ácido cítrico a 0,05 M (pH 2,3) por 60 minutos diários, também por 21 dias. Os fios foram avaliados quanto a sua rugosidade média, aferida pelo parâmetro Ra, em rugosímetro. A seguir, os fios foram submetidos a ensaios de atrito, realizados em uma máquina de testes universal, operando a uma velocidade de 3 mm/min, utilizando-se braquetes metálicos (Damon 3MX - Ormco). Com finalidade ilustrativa, obtiveram-se imagens em MFA. Os testes de Kruskal Wallis (p = 0,004) e de Dunn demonstraram que os fios de CuNiTi submetidos a DEs apresentaram valores de Ra significativamente superiores àqueles armazenados em saliva artificial, achado substanciado pela MFA. Os fios submetidos a DCs revelaram valores intermediários de Ra, não diferindo dos grupos imersos em saliva artificial ou na solução erosiva. A força de atrito estabelecida entre os fios e braquetes não foi significativamente influenciada pelos DCs ou DEs. Concluiu-se que frente a DEs, a rugosidade superficial do fio ortodôntico de CuNiTi tornou-se superior àquela causada pela saliva artificial... (AU)

This study examined the effect of cariogenic (CCs) and erosive challenges (ECs) on degradation of orthodontic wires fabricated in copper-nickel-titanium alloy (Copper NiTi), through roughness measurements and atomic force microscopy photomicrographs (AFM). In addition, friction established between passive self-ligating brackets and the aforementioned wires was evaluated following CCs and ECs. Sixty wires segments were distributed in four groups, to be submitted to CC or EC, that simulated their clinical use for 12 weeks, to be exposed to artificial saliva or to integrate the control group (no treatment). The CCs were performed with demineralizing solution (pH 4.3), used in physico-chemical caries models, in which wires were immersed for 24 hours, for 21 days. To simulate the condition of high EC, wires were stored in 0.05 M citric acid solution (pH 2.3) for 60 minutes daily, for 21 days. Wires were evaluated for average roughness (Ra), in perfilometer. Next, wires were submitted to friction tests, performed in a universal testing machine, at a crosshead speed of 3 mm/min, using metallic brackets (Damon 3MX - Ormco). AFM images were obtained with illustrative purpose. Kruskal-Wallis (p = 0.004) and Dunn tests demonstrated that Copper NiTi wires submitted to ECs presented Ra values significantly higher than those stored in artificial saliva. Such a finding was substantiated by AFM. Wires submitted to CCs revealed intermediate Ra values, not differing from the groups immersed in artificial saliva or erosive solution. Friction established between wires and brackets was not significantly influenced by ECs or CCs. It was concluded that the surface roughness of a Copper NiTi orthodontic wire immersed in ECs was higher than that caused by artificial saliva. There was no correlation between the surface roughness generated by the wire exposure to CCs, ECs or artificial saliva and the friction established between the wire and a passive self-ligating bracket (AU)
Responsável: BR1354.1 - Biblioteca São Leopoldo Mandic
BR1354.1


  8 / 24 BBO  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo
Id: 40695
Autor: Carvalho, Renata Castro Leal.
Título: Efeito da lubrificação no atrito entre braquetes e fios ortodônticos / Effect of lubrication on friction between brackets and orthodontic wires.
Fonte: Campinas, SP; s.n; 2012. 57 p. ilus.
Idioma: pt.
Tese: Apresentada a Centro de Pesquisas Odontológicas São Leopoldo Mandic para obtenção do grau de Mestre.
Resumo: O sucesso do movimento ortodôntico ocorre na dependência da mecânica de deslize entre braquetes e fio, a qual é influenciada pelo atrito entre ambos. O objetivo deste estudo foi avaliar o efeito da interposição de diferentes lubrificantes na força de atrito entre fios ortodônticos e braquetes autoligados, ativos e passivos. Os fatores em estudo foram Tipo de Braquete (ativo e passivo) e Condição de Lubrificação (ausente, como controle negativo; saliva natural humana, como controle positivo; água destilada, saliva artificial à base de mucina e saliva artificial à base de carboximetilcelulose). As unidades experimentais foram 50 braquetes autoligados ativo (Quick, Forestadent) e 50 passivos (Damon 3MX, Ormco), em cujos slots deslizou um fio com 0,014” x 0,025” de CuNiTi. Amostras de saliva humana total não estimulada foram coletadas de um único indivíduo, pela manhã, 2 horas após a ingestão de alimentos e realização da escovação dental. As demais salivas foram manipuladas em laboratório. Os braquetes foram aderidos a uma base cilíndrica acoplada a uma máquina de ensaios universal, sendo as amostras braquete/ fio ensaiadas na presença de uma das condições de lubrificação. O ensaio foi realizado oito vezes, a uma velocidade de 3 mm/min. A análise de variância a dois critérios demonstrou que não houve interação significativa entre os fatores em estudo Tipo de Braquete e Condição de Lubrificação (p = 0,324). A força de atrito proporcionada pelos braquetes autoligados passivos foi significativamente inferior àquela observada com a utilização de braquetes ativos (p < 0,001). O teste de Tukey revelou que os valores de força de atrito gerados com o emprego das salivas artificiais não diferiram daqueles verificados para no grupo em que se empregou saliva natural humana. Valores significativamente superiores de força de atrito foram observados nas condições em que se utilizou água destilada ou em que se realizou o ensaio sob atrito seco (lubrificante ausente)... (AU)

The success of the orthodontic movement occurs depending on the sliding mechanics between brackets and wire, which is influenced by friction between both. The purpose of this study was to evaluate the effect of interposition of different lubricants on friction between orthodontic wires and active and passive self-ligating brackets. Factors under study were Type of Bracket (active and passive) and Lubricant Condition (absent, as negative control; natural human saliva, as positive control; distilled water, mucin-based artificial saliva and carboxymethylcellulose (CMC)-based artificial saliva). The experimental units were 50 active self-ligating brackets (Quick, Forestadent) and 50 passive (Damon 3MX, Ormco), in which slots slided a 0.014” x 0.025” CuNiTi wire. Samples of unstimulated total human saliva were collected from a single donor, in the morning, 2 hours after food intake and brushing procedure. Artificial salivas were manipulated in laboratory. The brackets were bonded to a cylindrical base attached to a universal testing machine, where the bracket/wire samples were tested in the presence of one of the lubricant condition. Testing was performed eight times, at a 3 mm/min speed. Two-way analysis of variance showed that there was no significant interaction between the Type of Brackets and Lubricant Condition (p = 0.324). Friction provided by the passive self-ligating brackets was significantly lower than that noticed with the active brackets (p < 0.001). Tukey's test revealed that the friction generated with the application of artificial saliva did not differ from that found in the group tested with natural human saliva. Significantly higher friction was observed as a result of using distilled water or dry friction (no lubricant). In these two conditions friction was equivalent. It was concluded that active brackets produced higher friction compared with the passive counterparts, regardless of the lubricant condition... (AU)
Responsável: BR1354.1 - Biblioteca São Leopoldo Mandic
BR1354.1


  9 / 24 BBO  
              first record previous record next record last record
seleciona
para imprimir
Fotocópia
Texto completo SciELO Brasil
Texto completo
Id: 40652
Autor: Castro, Raquel Morais; Smith Neto, Perrin; Horta, Martinho Campolina Rebello; Pithon, Matheus Melo; Oliveira, Dauro Douglas.
Título: Comparison of static friction with self-ligating, modified slot design and conventional brackets
Fonte: J. appl. oral sci;21(4):314-319, July-Aug. 2013. ilus, tab.
Idioma: en.
Resumo: OBJECTIVE:To compare the static frictional forces generated at the bracket/wire interface of stainless steel brackets with different geometries and angulations, combined with orthodontic wires of different diameters.MATERIAL AND METHODS:The frictional forces were evaluated with three different types of metal brackets: a passive self-ligating (SmartClipTM, 3M/Unitek, Monrovia, USA), with a modified slot design (Mini Uni TwinTM, 3M/Unitek, Monrovia, USA) and conventional (Kirium, Abzil, São José do Rio Preto, Brazil). The samples were mounted in a testing device with three different angulations and tested with 0.014" and 0.018" stainless steel wires (American Orthodontics, Sheboygan, USA). The static frictional force was measured using a universal testing machine (DL 500, EMIC®, São José dos Pinhais, Brazil) with a crosshead speed of 1 mm/min. Statistical analysis was performed by two-way ANOVA followed by Bonferroni's post hoc test.RESULTS:There was a significant difference (p<0.05) in static friction when the three types of brackets were tested with the same wire size. The wire diameter influenced friction only when the brackets had a 10º angulation (p<0.05). The angulation influenced friction (p<0.05) when the brackets were associated with a 0.018" wire.CONCLUSION:Brackets with a modified slot design showed intermediate static frictional force values between the conventional and self-ligating brackets tested.(AU)
Responsável: BR28.1 - Serviço de Biblioteca e Documentação Professor Doutor Antônio Gabriel Atta


  10 / 24 BBO  
              first record previous record
seleciona
para imprimir
Fotocópia
Id: 40055
Autor: Pithon, Matheus Melo; Santana, Dandara de; Mendes, Bernardo de Azevedo Bahia; Souza, Ricardo Alves; Oliveira, Dauro Douglas.
Título: Influência de diferentes cremes dentais na rugosidade e atrito dos braquetes ortodônticos / Influence of different toothpastes in roughness and friction of orthodontic brackets
Fonte: Rev. clín. ortodon. Dental Press;12(3):102-111, jun.jul. 2013. ilus, tab.
Idioma: pt.
Resumo: Introdução: avaliar, in vitro, a rugosidade, a morfologia e os níveis de atrito oferecidos pelos braquetes antes e após a escovação com diferentes cremes dentais. Métodos: cento e dez braquetes metálicos foram aleatoriamente distribuídos em 11 grupos: 1 grupo controle (saliva artificial) e 10 grupos experimentais (n = 10). Após colagem dos braquetes em dispositivo específico, esses foram submetidos a três escovações diárias com diferentes tipos de cremes dentais durante um período de 28 dias. Os cremes dentais avaliados foram: Close Up Ação Profunda, Close Up Triple, Colgate Luminous White, Colgate Tripla Ação, Oral B Pró Saúde, Oral B Pró-Saúde Whiteness, Sensodine Fresh, Sensodine Original, Sorriso Fresh Plus e Sorriso Original. Entre as escovações, os braquetes foram lavados em água corrente e acondicionados em recipiente contendo saliva artificial e mantidos em estufa à temperatura de 37ºC. Para a avaliação da rugosidade foi utilizada microscopia eletrônica de varredura. As imagens obtidas foram avaliadas quantitativamente por meio de análise de imagem em histogramas. Os níveis de atrito foram medidos por uma máquina de dobramento. Os dados foram comparados estatisticamente por meio da ANOVA, utilizando o teste t de Student. Resultados: observou-se presença de ranhuras, sobretudo no grupo Colgate Luminous White. Houve diferenças estatísticas nos níveis de atrito entre os grupos Close Up Ação Profunda, Close Up Triple e Colgate Luminous White. Conclusão: o creme dental Colgate Luminous White apresentou maior rugosidade de superfície e maior nível de atrito; a menor rugosidade foi observada nos grupos Close Up Ação Profunda e Sorriso Fresh Plus. (AU)
Responsável: BR1141.1 - Biblioteca Central
BR1141.1



página 1 de 3 ir para página          
   


Refinar a pesquisa
  Base de dados : Formulário avançado   

    Pesquisar no campo  
1  
2
3
 
           



Search engine: iAH v2.6 powered by WWWISIS

BIREME/OPAS/OMS - Centro Latino-Americano e do Caribe de Informação em Ciências da Saúde