Morbimortalidad y factores de riesgo para ventilación mecánica prolongada en los pacientes de la Unidad de Terapia Intensiva del Hospital Nacional Hipólito Unanue / Morbidity and mortality and risk factors for mechanical ventilation in patients of Intensive Therapy Unit of the National Hospital Hipolito Unanue
Lima; s.n; 2013. 52 p. tab.
Tese em Espanhol | LILACS, LIPECS | ID: lil-724557
Biblioteca responsável: PE13.1
Localização: PE13.1; ME, WX, 218, G86, ej.1. 010000093238 / PE13.1; ME, WX, 218, G86, ej.2. 010000093239
RESUMEN

Objetivos:

Determinar la morbimortalidad en pacientes con ventilación mecánica prolongada en la UTI del Hospital Nacional Hipólito Unanue (2005-2007). Establecer los probables factores de riesgo para ventilación mecánica prolongada en los pacientes de la UTI del Hospital Nacional Hipólito Unanue (2005-2007). Material y

métodos:

Estudio observacional, analítico y descriptivo en 170 HC de pacientes con ventilación mecánica prolongada en la UTI, donde el instrumento principal de estudio fue la ficha de datos validada.

Resultados:

La edad promedio fue de 55.6±10.8 años, con mayor frecuencia de pacientes con edad entre 41>61 años, predominando el sexo masculino (55.90 por ciento). Las variables clínicas más frecuentes fueron HTA (49.40 por ciento), ciruela previa (40.60 por ciento), Escala de Glasgow (5-12) (24.70 por ciento), Apache II (5>25) (88.25 por ciento). Score Trauma (>2-7.8) (94.75 por ciento), Falla respiratoria (90.60 por ciento), Sepsis / shock séptico (38.95 por ciento), Post quirúrgico (31.15 por ciento), ARDS (18.20 por ciento), Sedación >3 días (74.70 por ciento), Pa/FIO2 (150-299) (88.25 por ciento), BH acumulado / 1500 (50 por ciento). El destete SIMV + PS (20.20 por ciento). La tasa de mortalidad fue de 32.35 por ciento y de morbilidad 23.50 por ciento.

Conclusiones:

La ventilación mecánica prolongada prevaleció en el 39 por ciento de esta población. La morbilidad en los pacientes con ventilación mecánica prolongada se presentó en el 23.50 por ciento de los casos y la mortalidad en el 32.35 por ciento. Las complicaciones propias de la ventilación mecánica prolongada más frecuentes fueron Disfunción Orgánica Múltiple, choque, sepsis, NAVM y ARDS. Los factores de riesgo para ventilación mecánica prolongada fueron edad mayor de 41 años, sexo masculino, hipertensión arterial, cirugía previa, escala de Glasgow, Score Apache II, Score trauma, Falla respiratoria aguda, Sepsis / shock séptico, ARDS, sedación > 72 horas, Pa/FIO2 a las 48 horas <200...
ABSTRACT

Objectives:

To determine the morbidity and mortality in patients with prolonged mechanical ventilation in the ICU of the National Hospital Hipolito Unanue (2005-2007). Establish the likely risk factors for prolonged mechanical ventilation in ICU patients Hipolito Unanue National Hospital (2005-2007).

Methods:

An observational, analytical and descriptive HC in 170 patients with prolonged mechanical ventilation in the ICU, where the main study instrument was validated data sheet.

Results:

Mean age was 55.6±10.8 years, more frequently in patients aged between 41>61 years, mainly boys (55.90 per cent). The most common clinical variables were hypertension (49.40 per cent), previous surgery (40.60 per cent), Glasgow Scale (5-12) (24.70 per cent), Apache II (5> 25) (88.25 per cent). Score Trauma (> 2-7.8) (94.75 per cent), respiratory failure (90.60 per cent), sepsis / septic shock (38.95 per cent), Post surgical (31.15 per cent), ARDS (18.20 per cent), sedation >3 days (74.70 per cent), Pa/FIO2 (150- 299) (88.25 per cent), accumulated BH / 1500 (50 per cent). Weaning SIMV + PS (20.20 per cent). The mortality rate was 32.35 per cent and 23.50 per cent morbidity.

Conclusions:

Prolonged mechanical ventilation prevailed in 39 per cent of this population. The morbidity in patients with prolonged mechanical ventilation was presented in 23.50 per cent of cases and mortality in 32.35 per cent. The complications of prolonged mechanical ventilation were the most common multiple organ dysfunction, shock, sepsis, VAP and ARDS. Risk factors for prolonged mechanical ventilation were age over 41 years, male sex, hypertension, previous surgery, GCS, APACHE II score, Score trauma, acute respiratory failure, sepsis / septic shock, ARDS, sedation >72 hours to 48 hours Pa/FIO2 <200, and accumulated water balance >1500.
Assuntos

Buscar no Google
Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Respiração Artificial / Fatores de Risco / Unidades de Terapia Intensiva Tipo de estudo: Estudo de etiologia / Avaliação de tecnologias de saúde / Estudo observacional / Fatores de risco Limite: Adulto / Idoso / Idoso, 80 anos ou mais / Feminino / Humanos / Masculino Idioma: Espanhol Ano de publicação: 2013 Tipo de documento: Tese
Buscar no Google
Coleções: Bases de dados nacionais / Peru Base de dados: LILACS / LIPECS Assunto principal: Respiração Artificial / Fatores de Risco / Unidades de Terapia Intensiva Tipo de estudo: Estudo de etiologia / Avaliação de tecnologias de saúde / Estudo observacional / Fatores de risco Limite: Adulto / Idoso / Idoso, 80 anos ou mais / Feminino / Humanos / Masculino Idioma: Espanhol Ano de publicação: 2013 Tipo de documento: Tese
...